• 제목/요약/키워드: Polyether

검색결과 189건 처리시간 0.021초

Investigation of the effects of storage time on the dimensional accuracy of impression materials using cone beam computed tomography

  • Alkurt, Murat;Duymus, Zeynep Yesil;Dedeoglu, Numan
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.380-387
    • /
    • 2016
  • PURPOSE. The storage conditions of impressions affect the dimensional accuracy of the impression materials. The aim of the study was to assess the effects of storage time on dimensional accuracy of five different impression materials by cone beam computed tomography (CBCT). MATERIALS AND METHODS. Polyether (Impregum), hydrocolloid (Hydrogum and Alginoplast), and silicone (Zetaflow and Honigum) impression materials were used for impressions taken from an acrylic master model. The impressions were poured and subjected to four different storage times: immediate use, and 1, 3, and 5 days of storage. Line 1 (between right and left first molar mesiobuccal cusp tips) and Line 2 (between right and left canine tips) were measured on a CBCT scanned model, and time dependent mean differences were analyzed by two-way univariate and Duncan's test (${\alpha}=.05$). RESULTS. For Line 1, the total mean difference of Impregum and Hydrogum were statistically different from Alginoplast (P<.05), while Zetaflow and Honigum had smaller discrepancies. Alginoplast resulted in more difference than the other impressions (P<.05). For Line 2, the total mean difference of Impregum was statistically different from the other impressions. Significant differences were observed in Line 1 and Line 2 for the different storage periods (P<.05). CONCLUSION. The dimensional accuracy of impression material is clinically acceptable if the impression material is stored in suitable conditions.

Polyether Polyol을 이용한 수분산 폴리우레탄의 1,4-butanediol 사슬연장에 의한 물성변화 (A Study on Measurement of Mechanical Properties of Polyther Polyol Base Polyurethane Dispersion by 1,4-butanediol Chain Extension)

  • 이주엽
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.711-718
    • /
    • 2014
  • 본 논문에서는 피혁에 사용되는 수용성 폴리우레탄 사슬 연장제인 1,4-butanediol(1,4-BD)의 함유에 따른 물성변화를 조사하였다. 합성에 사용된 시약은 poly propylene glycol(PPG), isoporon diisocyanate((IPDI), dimethylolpropionic acid(DMPA), 1,4-BD를 사용하였다. 1,4-BD의 함유에 따른 내용제성과 내굴곡성 측정값은 시료 전부 우수한 물성을 보였다. 인장강도, 내마모성 측정결과 1,4-BD가 많이 함유된 시료들이 각각 $1.80kg_f/mm^2$, 49.54 mg.loss로 우수한 물성을 확인하였다. 연실율 측정결과 1,4-BD가 적게 함유된 시료가 364%로 가장 우수한 측정값을 나타냈다.

Effect of temperature on the rheological properties of dental interocclusal recording materials

  • Pae, Ahran;Lee, Ho-Rim;Kim, Hyeong-Seob
    • Korea-Australia Rheology Journal
    • /
    • 제20권4호
    • /
    • pp.221-226
    • /
    • 2008
  • The purpose of this study was to compare rheological properties of six dental interocclusal recording materials and to investigate the effect of temperature on the rheological properties during setting. Five polyvinylsiloxane materials and one polyether material were investigated in this study. The storage modulus (G') and the loss factor ($tan{\delta}$) were measured from 30s after mixing during setting, using the universal dynamic spectrometer. Viscoelastic properties were evaluated by means of G' and $tan{\delta}$ from 5 repeats at $21^{\circ}C$ and $33^{\circ}C$. Individual changes during setting were also evaluated. All data were statistically analyzed using one-way ANOVA and multiple comparison $Scheff{\acute{e}}$ test at the significance level of 0.05. The mean of G was checked at $t_{set}$ (the setting time provided from manufacturer) and $t_{300}$ (the end of experimental time) and the mean of $tan{\delta}$ was checked at to and $t_{set}$. Whereas the increase of the G' value showed generally exponential changes at $21^{\circ}C$, the change of the G' value at $33^{\circ}C$ displayed sigmoidal curves during setting. The change of loss factor $tan{\delta}$ during setting varied. Within the limitations of this study, dental interocclusal recording materials had different viscoelastic properties and most of the materials showed different fluidity at $21^{\circ}C$ and $33^{\circ}C$.

섬유금속적층판 제작을 위한 PTFE 몰드 기반 마이크로파 공정에 대한 실험적 연구 (Experimental Study on Manufacturing Fiber Metal Laminate using Microwave Heating Based on PTFE Mold)

  • 박으뜸;이영헌;김정;강범수;송우진
    • 소성∙가공
    • /
    • 제29권4호
    • /
    • pp.179-187
    • /
    • 2020
  • Existing composite forming processes such as the autoclave, prepreg compression forming (PCF), RTM, etc. require high production costs because of their long processing time. On the other hand, microwave heating process (MHP) can reduce the production costs since both mold and composite material can be heated directly. The aim of this study is to manufacture a mold consisting of polytetrafluoroethylene (PTFE), quartz glass, stainless steel clamps, and polyether ether ketone (PEEK) bolts for fabricating FML based on self-reinforced polypropylene (SRPP) using the MHP. First, the flame test was carried out prior to the MHP to check the temperature on the mold and whether the spark occurred at the mold and the edge of the FML. Second, the uniaxial tensile test was then conducted to obtain the mechanical properties of the FML manufactured by the MHP. The mechanical properties were compared with those of the FML fabricated by the PCF. As a result, the MHP using the PTFE mold can manufacture the FML more rapidly than the PCF, and obtain acceptable mechanical properties.

Production and Biological Activity of Laidlomycin, Anti-MRSA/VRE Antibiotic from Streptomyces sp. CS684

  • Yoo, Jin-Cheol;Kim, Jun-Ho;Ha, Jung-Wan;Park, Nae-Soo;Sohng, Jae-Kyung;Lee, June-Woo;Park, Seong-Chan;Kim, Mi-Sun;Seong, Chi-Nam
    • Journal of Microbiology
    • /
    • 제45권1호
    • /
    • pp.6-10
    • /
    • 2007
  • Culture broth of a streptomycete isolate, Streptomyces sp. CS684 showed antibacterial activity on methicilin resistant Staphylococcus aureus (MRSA) and vancomycin resistant enterococci (VRE). Among purified substances from the organism, CSU-1, which is active against MRSA and VRE, is a $C_{37}H_{62}O_{12}Na\;(M^+,721.3875)$, and identified as laidlomycin. The anti-MRSA and anti-VRE activity of CSU-1 was stronger than oxacillin and vancomycin. Phylogenetic analysis showed that strain CS684 is very similar to Streptomyces ardus NRRL $2817^T$, whereas the ability of Streptomyces sp. CS684 to produce laidlomycin was shown to be unique.

근관형성 방법에 따른 근관변위와 잔존치질의 두께에 관한 연구 (EVALUATION OF ROOT CANAL TRANSPORTATION AND REMAINING DENTIN/CEMENTUM THICKNESS FOLLOWING HAND AND ULTRASONIC INSTRUMENTATION)

  • 서병곤;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.399-412
    • /
    • 1992
  • The purpose of this study was to evaluate the root canal transportation and remaining dentin / cementum thickness after using hand and ultrasonic instrumentation in the curved mesial root canals of extracted human mandibular molars. Fourty - six clear polyether blocks were made and randomly divided into two groups: hand instrumentation group with K - Flex files and ultrasonic instrumentation group with Suprasson SP unit. All root canals were instrumented to a size corresponding to a # 30 K - Flex file 1mm short from the radiographic apex. The roots were then sectioned perpendicular to the long axis so the apical and middle third could be evaluated with the Zoom stereomicroscope. The results were as follows : 1. In the total amount of removed dentin at middle third level, there was not significant difference between the hand instrumentation and ultrasonic instrumentation (P>0.05). 2. In the total amount of removed dentin at apical third level, there was more removed by the ultrasonic instrumentation than hand instrumentation(P<0.005). 3. In the transportation width, there was not significant difference between the two groups at both sectioned levels(P>0.05). 4. It was suggested that the canal was transported distally at middle third level and mesially at apical third level by booth techniques.

  • PDF

Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes

  • Oh, Hyun-Joon;Cha, Geun-Sig;Nam, Hak-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • We examined the effect of polyether-type nonionic surfactants (Brij 35, Triton X-100, Tween 20 and Tween 80) on the potentiometric properties of sodium-, potassium- and calcium-selective membranes which are prepared with widely used ionophores and four kinds of polymer matrices [poly(vinyl chloride) (PVC), polyurethane (PU), PVC/PU blend, and silicone rubber (SR)]. It was found that the PVC-based membranes, which provide the best performance among all other matrix-based membranes in the absence of nonionic surfactants, exhibited larger change in their potentiometric properties when nonionic surfactants are added to the sample solution. On the other hand, the sodium-selective SR-based membrane with calix[4]arene, potassium-selective PVC/PU- or SR-based membrane with valinomycin, and the calcium-selective SR-based membrane with ETH 1001 provide almost identical analytical performance in the presence and absence of Tween 20 or Tween 80 surfactants. The origin of nonionic surfactants effect was also investigated by interpreting the experimental results obtained with various matrices and ionophores. The results suggest that the nonionic surfactant extracted into the membrane phase unselectively form complexes with the primary and interfering ions, resulting in increased background potential and lower binding ability for the ionophore. Such effects should result in deteriorated detection limits, reduced response slopes and lower selectivity for the primary ions.

탄화수소계열 수전해용 공유가교 SPEEK/Cellulose 복합막의 다양한 함량의 가교제에 따른 제조 및 특성 (Preparation and Characterization of Covalently Cross-linked SPEEK/Cellulose Composite Membranes with Various Cross Linkage Contents for Water Electrolysis)

  • 김보영;김민진;윤영요;문상봉;정장훈
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.411-418
    • /
    • 2018
  • The polymer electrolyte membranes, CL-SPEEK/Cellulose composite membrane I, II, III with the improved electrochemical and mechanical properties were prepared and characterized. The engineering plastic polyether ether ketone (PEEK) and cellulose were sulfonated and cross-linked. The membranes were prepared by sol-gel casting method with different amount of cross-linking reagent. In conclusion, the composite membranes I, II, III showed improved thermostability, tensile strength and oxidative durability. Proton conductivity of the membranes was also improved and the composite membrane I showed 0.1312 S/cm at $80^{\circ}C$ which was the best of those composite membranes.

Thermal Decomposition of Ammonium Polyphosphate-Polyurethane Composite Foam Brown by H2O

  • Park, Kyeong-Kyu;Lee, Sang-Ho
    • Elastomers and Composites
    • /
    • 제50권4호
    • /
    • pp.297-303
    • /
    • 2015
  • Ammonium polyphosphate-polyurethane foam composite (APP-PUF) was prepared from poly(adipate)diol/ammonium polyphosphate composite (f = 2), polyether polyol (f = 4.6), and PMDI (f = 2.5). As a blowing agent, $H_2O$ was used at various concentrations. The thermal decomposition behavior, morphology, closed-cell content, and density of APP-PUF were characterized. At the $H_2O$ concentrations lower than 3.5 php, the cell size of pure polyurethane foams (PUF) and APP-PUFs were close each other. As the $H_2O$ concentration became greater than 5.0 php, the cell size of the PUFs greatly increased compared to that of APP-PUFs. Addition of 1.5~1.9 wt% ammonium polyphosphate to the PUFs greatly enhanced the thermal stability of the PUFs, so 50 wt% residual temperature of APP-PUFs increased to $380{\sim}488^{\circ}C$, which were $30{\sim}70^{\circ}C$ higher than those of the PUFs. Thermal stability of the PUFs and APP-PUFs increased with $H_2O$ content and then decreased once $H_2O$ content exceeded 5 php.

Holographic Interferometry를 이용한 탄성 고무 인상재의 체적변화에 관한 연구 (DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS USING HOLOGRAPHIC INTERFEROMETRY)

  • 하치양;이성복;우이형
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.574-592
    • /
    • 1996
  • This study investigated the time-dependent dimensional changes of elastomeric impression materials using holographic interferometry. Six commercial impression materials, Permlastic(polysulfide), Xantopren VL (condensation silicone), low and medium viscosity of Exafine, Provil (addition silicone), and Impregum(polyether), were selected. Steel plate was used as custom tray, and each impression specimen was 20 mm in width, 15 mm in length and 3 mm in thickness. Each impression material was evaluated at 30 minutes, 1, 2, 4, 6, 8 and 12 hours after setting using real-time holography. The results were as follow : 1. Xantopren VL and Permlastic showed relatively severe and continuous dimensional changes after setting. Low viscosity of Exafine, Provil, Impregum showed relatively slight dimensional changes with function of time and medium viscosity of Exafine showed almost no dimensional change from 2 hours after setting to 6 hours. 2. On initial dimensional changes within 1 hour, the amount of change in low viscosity of Exafine was the least and Xantopren VL was the largest. 3. On dimensional changes at 4 hours after setting, the amount of change in medium viscosity of Exafine was the least and tile change of Xantopren VL was the largest. 4. In overall dimensional stability during 12 hours, medium viscosity of Exafine was the most stable and Xantopren VL and Permlastic were least stable.

  • PDF