• 제목/요약/키워드: Polycarboxylate

검색결과 86건 처리시간 0.022초

시멘트 유지형 임플란트 보철물의 유지력에 시멘트의 종류와 열순환이 미치는 영향에 관한 연구 (EFFECTS OF VARIOUS CEMENTS AND THERMOCYCLING ON RETENTIVE STRENGTHS OF CEMENTED IMPLANT-SUPPORTED PROSTHESES)

  • 조재호;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.466-475
    • /
    • 2003
  • Statement of problem : In cemented implant-supported porstheses, it is still controversy what kind of cement to use. However, the effect of thermocycling on retentive strength of cemented implant-supported prostheses has not been well investigated. Purpose : This study was tested to evaluate the effects of various cements and thermocycling on retentive strengths of cemented implant-supported prostheses. Material and methods : Prefabricated implant abutments, height 5mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were used. Ten specimens of two-unit fred partial denture were fabricated. The luting agents used for this study were three provisional luting agents which were Temp bond, Temp bond NE, IRM and four permanent luting agents which were Panavia F, Fuji-cem, Hy-bond Zinc cement, Hy-bond Polycarboxylate cement. 24 hours after cementation. the retentive strengths were measured by the universal testing machine with a cross-head speed of 0.5mm/min. Then cementation procedures were repeated and specimens were thermocycled 1000 times at temperature of $5^{\circ}C$ and $55^{\circ}C$. After thermocycling, the retentive strengths were measured. Results : Before thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem. Hy-bond Zinc cement. Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were significant differences among each groups(p<0.05). After thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem, Hybond Zinc cement, Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were no significant differences among Panavia F, Fuji-cem and Temp bond NE, Temp bond(p>0.05). The retentive strengths before and after thermocycling showed significant differences in Hy-bond Zinc cement. IRM, Temp bond NE and Temp bond(p<0.05). Conclusion : Within the limitation of this study, thermocycling do not affect the retentive strengths of permanent luting agents but the retentive strengths of temporary cements were reduced significantly after thermocyling.

고강도용 폴리카르본산계 고성능 감수제가 사용된 콘크리트의 성능 (The Performance of Concrete Used High Strength Development Polycarboxylate Superplasticizer)

  • 이완조;강성구;황인동;이재용;박성;정윤중
    • 한국세라믹학회지
    • /
    • 제42권3호
    • /
    • pp.182-187
    • /
    • 2005
  • 최근 국내에 소개된 폴리카르본산계의 종류는 기능적 분류로 감수용, 유지용, 초고강도용 등으로 소개되고 있으며 이들은 각기 화학적 구조의 차이와 시멘트와 혼합 후 거동의 차이에 의하여 각기 다른 물리적 특성을 보였으며 감수용의 경우 시멘트 중량의 $1.2\%의 사용시 $30\% 이상의 높은 감수율을 보였으나 골재분리를 동반하였으며 콘크리트 제조 후 45분 경과시 슬럼프 플로우의 감소가 약 30cm 이상 발생하였으며 유지용의 경우 롱일 사용량에서 약 $25\% 감수율을 보였으며 45분까지의 슬림프 플로우의 경시 변화는 15cm 이하로 관찰되었다. 초고강도용의 경우 시멘트 중량의 $1.2\%를 사용한 경우 $30\% 이상의 감수율로 관찰되었으며 슬럼프 플로우의 45분 후의 경시변화는 100m 이하로 측정되었다. 압축갔도의 경우 초고강도용의 경우 탁월한 조기 강도 증진 효과를 보였으며 특정배합에서의 18시간 압축강도는 약 $60\;Kgf/cm^2$ 이상이 확보될 수 있었으며 24시간에서 $80\;Kgf/cm^2$이상이 확보될 수 있었다.

치과용 임시합착 시멘트가 영구합착 시멘트의 결합력에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT OF TEMPORARY CEMENTS ON THE BOND STRENGTH OF PERMANENT CEMENTS)

  • 이진호;이호용;한동후
    • 대한치과의사협회지
    • /
    • 제22권9호통권184호
    • /
    • pp.803-811
    • /
    • 1984
  • The purpose of this study was to research how temporary cementation effected on the bond strength of permanent cementation. Zinc phosphate, polycarboxylate and EBA ZOE cements were used as permanent cements, and as temporary cements Nogenol, Tempak and Dycal were used. The ninety six (96) specimens were prepared to measure the bond strength of permanent cements after treated with temporary cements for one week. The tensile stregths were measured with an Instron Universal Test Machine. The results of this study were obtained as follows: 1. With zinc phosphate cement, there was a tendency that the bond strengths of the group of temporarily cemented with Nogenol were increased, meanwhile they were decreased a little in the groups of Dycal and Tempak than those of the control group. 2. With polycarboxylate cement, there was a tendency that the bond strengths of the Control group were higher than those of experimental groups and they were decreased in order of Tempak, Noginol, and Dycal. 3. With EBA ZOE cement, there was a tendency that the bond strengths of the group of temporarily cemented with Tempak were increased a little, meanwhile they were decreased a little in the groups of Nogenol and Dycal than those of the Control group. 4. Among the permanent cements, the bond strengths of polycarbosylate cement were the highest and were followed in order of zinc phosphate cement and EBA ZOE cement.

  • PDF

Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces

  • Ozer, Fusun;Pak-Tunc, Elif;Dagli, Nesrin Esen;Ramachandran, Deepika;Sen, Deniz;Blatz, Markus Bernhard
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.340-346
    • /
    • 2018
  • PURPOSE. In this study, the shear bond strengths (SBS) of luting cements to fixed superstructure metal surfaces under various seating forces were investigated. MATERIALS AND METHODS. Seven different cements [Polycarboxylate (PCC), Glass-Ionomer (GIC), Zinc phospahate (ZPC), Self-adhesive resin (RXU), Resin (C&B), and Temporary cements ((RXT) and (TCS))] were bonded to a total number of 224 square blocks ($5{\times}5{\times}3mm$) made of one pure metal [Titanium (CP Ti) and two metal alloys [Gold-Platinum (Au-Pt) and Cobalt-Chrome (Co-Cr)] under 10 N and 50 N seating forces. SBS values were determined and data were analyzed with 3-way ANOVA. Pairwise comparisons and interactions among groups were analyzed with Tukey's simultaneous confidence intervals. RESULTS. Overall mean scores indicated that Co-Cr showed the highest SBS values ($1.96{\pm}0.4$) (P<.00), while Au-Pt showed the lowest among all metals tested ($1.57{\pm}0.4$) (P<.00). Except for PCC/CP Ti, RXU/CP Ti, and GIC/Au-Pt factor level combinations (P<.00), the cements tested under 10 N seating force showed no significantly higher SBS values when compared to the values of those tested under 50 N seating force (P>.05). The PCC cement showed the highest mean SBS score ($3.59{\pm}0.07$) among all cements tested (P<.00), while the resin-based temporary luting cement RXT showed the lowest ($0.39{\pm}0.07$) (P<.00). CONCLUSION. Polycarboxylate cement provides reliable bonding performance to metal surfaces. Resin-based temporary luting cements can be used when retrievability is needed. GIC is not suitable for permanent cementation of fixed dental prostheses consisting of CP Ti or Au-Pt substructures.

치과용 시멘트 용액의 증발이 경화된 시멘트의 성질에 미치는 영향 (INFLUENCE OF THE EVAPORATOIN OF LIQUIDS OF DENTAL CEMENTS ON THE PROPERTIES OF HARDENED CEMENTS)

  • 김향경;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.156-169
    • /
    • 1997
  • This study was designed to evaluate the influences of evaporation of liquid of dental cements by drying during long term using. Zinc phosphate cement, polycarboxylate cement, and glass ionomer cement were used, and evaluated the properties as follows; consistency, setting time, film thickness, solubility, and compressive strength according to the ADA specification. The specimens of control group were made by mixing the newly opened liquid using the powder-liquid ratio recommended by the manufacturer, and the specimens of ES groups were made by mixing the 10% evaporated liquid by drying with the powder-liquid ratio recommeded by the manufacturer, and the specimens of EM group were made by mixing the 10% evaporated liquid with the powder-liquid ratio modified for standard consistency. The following conclusions were drawn ; 1. The viscosity of mixture of all kinds of cements were increased by the evaporation of liquid, especially the viscosity of glass ionomer cement were influenced significantly. 2. The amount of liquid should be increased to get a standard consistency at the using of evaporated liquid of cement, the most significant increase of liquid amount was required on Ketac-Cem. 3. The setting times were increased at both cases of mixing of evaporated liquid with powder - liquid ratio recommended by manufacturer or modifided through consistency test. 4. At an experimental group of mixing of the evaporated liquid with powder-liquid ratio recommended by manufacturer, solubility was decreased and film thickness was increased. 5. By the result of evaporation of cement liquid, the compressive strength of polycarboxylate cement was increased slightly and it of glass ionomer cement was increased, however, by the increase of amount of liquid to be possible to manipulate the compressive strength were decreased.

  • PDF

치과용 Glass Polyalkenoate cement의 방사선 불투과성에 관한 비교 연구 (RADIOPACITY OF DENTAL GLASS POLYALKENOATE CEMENTS)

  • 임영일;엄정문;이정식;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.464-469
    • /
    • 1997
  • The radiopacity of glass ionomer cements is quite variable. The use of a poorly radiopaque material as a base under other restorative materials can mislead the dentist to a diagnosis of recurrent decay. This study investigates the radiopacity of these materials and proposes a minimal radiopacity under which a material should not be used as a base or liner. It is important to determine the radiopacity of glass ionomer dental materials so that the clinician can appreciate the type of restorative materials used when radiographically evaluation the possibility of recurrent dental caries. In this study, radiopacity of Vitrement and Chemfil was compared with that of Cavalite, Miracle mix and polycarboxylate cement. Tooth model of artificial cavity preparation for diagnosis of recurrent caries was omitted. Radiopacity of each material was measured using relatives between thickness and radiopacity of Aluminium step wedge. The results were as follows : 1. Radiopacity of Vitrement was some higher than enamel. 2. Chemfil, restorative glass ionomer, was less radiopaque than enamel. 3. In order of higher radiopacity than enamel, Miracle mix was highest and was followed by polycarboxylate cement, Cavalite and Vitremer. 4. Vitremer, the Glass Ionomer Cement, is useful to detection of recurrent caries, because it is slightly higher radiopaque than enamel. So, it is suitable for restorative material and luting cement.

  • PDF

혼화제 종류에 따른 메타카올린 콘크리트의 특성 (Properties of Metakaolin Concrete containing Various Superplasticizers)

  • 안태호;김용태;강범구;김병기
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.539-544
    • /
    • 2002
  • The properties of mortar and concrete including metakaolin as a partial cement replacement were investigated in terms of fluidity and compressive strength. The results show that mortar and concrete in which 10 % of cement is replaced with metakaolin exhibit much higher compressive strength after 3 days of hydration than ordinary Portland cement, indicating that metakaolin can be used in the production of high strength concrete replacing silica fume. The type of superplasticizer largely affected on the fluidity and compressive strength of mortar and concrete including metakaolin. It was concluded that when metakaolin is used for the purpose of manufacturing high strength concrete, it is desirable to use PNS based blends rather than PNS, PMS and polycarboxylate based superplasticizer.

  • PDF

Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향 (THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT)

  • 하점임;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

치과용(齒科用) Cement가 Pin Retention에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON PIN RETENTION OF THE DENTAL CEMENTS)

  • 김성간
    • 대한치과보철학회지
    • /
    • 제13권1호
    • /
    • pp.23-26
    • /
    • 1975
  • The purpose of this study was to measure the retentive force of various kinds of dental cement. Cross-cutting the half of the occlusal surface, pinholes were prepared on the dentin with No. 557 carbide bur. No. 557 steel burs were cemented in the pinholes and retentive force was measured by removing the burs with Instron testing machine. The Instron testing machine was operated at a rate of 0.2 cm per minute. The following results were obtained : 1. The retentive force of zinc phosphate cement(A), reinforced zinc oxide and eugenol cement and polycarboxylate cement were similar to each other, but that of zinc phosphate cement (A) was the highest of all. 2. The retentive force of zinc phosphate cement (B) was the lowest of all.

  • PDF