• Title/Summary/Keyword: Pollution variable

Search Result 145, Processing Time 0.023 seconds

The Study on the Level of Air Pollution at Four Department Stores in Pusan Area (부산지역 4개 백화점의 공기오염도에 관한 조사연구)

  • Moon, D.H.;Rhee, HW.;Lee, C.U.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.164-180
    • /
    • 1991
  • For the purpose of contributing to the promotion of health of the employees working at the same kind of department store or similar type of business and the people utilizing them and preparing the basic data for the establishment of mangagement measure by assessing the level of air pollusion at indoor and outodoor of four department store among the distribution service business in Pusan area, authors measured the concentration of sulfur dioxide, nitrogen dioxide, formaldehyde and total suspanded particle according to the measuring height of variable at indoor and outodoor from Aug. 1990. to sep. an. d Jan, 1991 to Feb.: for each two months in summer and winter, and studied by dividing the variable factor into atmospheric factor (temperature, humidity and air velociy) The results are as follows ; 1. The mean concentration of air pollutants at indoor to total subjects was nitrogen dioxide 31.1ppb, sulfur dioxide 51.7ppb, formaldehyde 162.lppb and total suspanded particle $67.7{\mu}g/m^3$, and it was higher in winter than in summer (P>0.05) 2. The mean concentration of formaldehyde to total subjects was higher indoors than outdoors (P<0.001), in case of nitrogen dioxide there was no significant difference and sulfur dioxide and total suspanded particle were higher outdoors than indoors (P<0.05) 3. The concentration of nitrogen dioxide and sulfur dioxide proved to be a adverse correlation, reducing with height. 4. According to the result questioned about the exposure concentration of pollutant and the general symptom caused by the pollutant, nitorgen dioxide and symptom proved to be a positive correlation (P<0.09).

  • PDF

Causes and Overcoming of the Algae Excess in a Dam Water - Based on the Data of Water Quality Analysis of Mulgum Area - (댐호화된 하천의 조류 과다 발생원인과 해소 방안 - 낙동강 물금 지역의 수질 분석 데이터를 중심으로 -)

  • Yang, Shi-Chun;Xia, Tian-Tian;Kang, Tai-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.4
    • /
    • pp.1-13
    • /
    • 2017
  • The purpose of this study is to analyze a term of decade of water quality data of the Mulgum intake station on the Nakdong river(dam) to find the cause of algal blooms and to set an alternative to prevent artificial lake water pollution. Our study shows that water quality changes have regular periodic regularity and there was a certain correlation between specific analytical items. According to the analysis results of each factor, the decline in precipitation was not the main reason for algal blooms. TP concentration had a slight effect on Chl-a concentration but was not a limiting nutrient of a bloom. TN concentration had a strong correlation with Chl-a and strongly negative correlation with temperature, but was not a bloom's limiting nutrient, and was only a dependent variable. As the temperature was negatively correlated with the Chl-a concentration, it is found that the aspect of the ecological influence of the temperature was the most important factor of the phytoplankton concentration change. The N/P ratio lies under a power function with a high degree of reliability by the TP concentration, and the phenomenon appeared to be the same as the results of two other comparative areas. This result confirms that TN is dependent on TP and the biota in the lake that TN is a dependent variable whose concentration is determined by TP it. In conclusion, the increase in lake bloom is the result of a food chain change, and it is necessary to control the ecosystem by the food chain in the lake in order to reduce the lake's bloom. In particular, it is important to keep the benthic ecosystem as wide as possible in the aerobic state.

Power Generation Cost Comparison of Nuclear and Coal Power Plants in Year 2001 under Future Korean Environmental Regulations -Sensitivity and Uncertainty Analysis- (미래의 한국의 환경규제여건에 따른 2001년도의 원자력과 석탄화력 발전단가비교 -민감도와 불확실도 분석-)

  • Lee, Byong-Whi;Oh, Sung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.18-31
    • /
    • 1989
  • To analyze the impact of air pollution control on electricity generation cost, a computer program was developed. POGEN calculates levelized discounted power generation cost including additional air pollution control cost for coal power plant. Pollution subprogram calculates total capital and variable costs using governing equations for flue gas control. The costs are used as additional input for levelized discounted power generation cost subprogram. Pollution output for Rue Gas Desulphurization direct cost was verified using published cost data of well experienced industrialized countries. The power generation costs for the year 2001 were estimated by POGEN for three different regulatory scenarios imposed on coal power plant, and by levelized discounted power generation cost subprogram for nuclear power. Because of uncertainty expected in input variables for future plants, sensitivity and uncertainty analysis were made to check the importance and uncertainty propagation of the input variables using Latin Hypercube Sampling and Multiple Least Square method. Most sensitive parameter for levelized discounted power generation cost is discount rate for both nuclear and coal. The control cost for flue gas alone reaches additional 9-11 mills/kWh with standard deviation less than 1.3 mills/kWh. This cost will be nearly 20% of power generation cost and 40% of one GW capacity coal power plant investment cost. With 90% confidence, the generation cost of nuclear power plant will be 32.6-51.9 mills/kWh, and for the coal power plant it will be 45.5-50.5 mills/kWh. Nuclear is favorable with 95% confidence under stringent future regulatory requirement in Korea.

  • PDF

Input Variable Selection by Using Fixed-Point ICA and Adaptive Partition Mutual Information Estimation (고정점 알고리즘의 독립성분분석과 적응분할의 상호정보 추정에 의한 입력변수선택)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.5
    • /
    • pp.525-530
    • /
    • 2006
  • This paper presents an efficient input variable selection method using both fixed-point independent component analysis(FP-ICA) and adaptive partition mutual information(AP-MI) estimation. FP-ICA which is based on secant method, is applied to quickly find the independence between input variables. AP-MI estimation is also applied to estimate an accurate dependence information by equally partitioning the samples of input variable for calculating the probability density function(PDF). The proposed method has been applied to 2 problems for selecting the input variables, which are the 7 artificial signals of 500 samples and the 24 environmental pollution signals of 55 samples, respectively The experimental results show that the proposed methods has a fast and accurate selection performance. The proposed method has also respectively better performance than AP-MI estimation without the FP-ICA and regular partition MI estimation.

A Study of Nitrous Oxide Thermal Decomposition and Reaction Rate in High Temperature Inert Gas (고온 불활성 기체 분위기에서 아산화질소 열분해 및 반응속도에 관한 연구)

  • Lee, Han Min;Yun, Jae Geun;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.25 no.3
    • /
    • pp.132-138
    • /
    • 2020
  • N2O is hazardous atmosphere pollution matter which can damage the ozone layer and cause green house effect. There are many other nitrogen oxide emission control but N2O has no its particular method. Preventing further environmental pollution and global warming, it is essential to control N2O emission from industrial machines. In this study, the thermal decomposition experiment of N2O gas mixture is conducted by using cylindrical reactor to figure out N2O reduction and NO formation. And CHEMKIN calculation is conducted to figure out reaction rate and mechanism. Residence time of the N2O gas in the reactor is set as experimental variable to imitate real SNCR system. As a result, most of the nitrogen components are converted into N2. Reaction rate of the N2O gas decreases with N2O emitted concentration. At 800℃ and 900℃, N2O reduction variance and NO concentration are increased with residence time and temperature. However, at 1000℃, N2O reduction variance and NO concentration are deceased in 40s due to forward reaction rate diminished and reverse reaction rate appeared.

A study on the inner flow fields characteristics of the Semi-active muffler (반능동형 머플러 내부의 유동장특성에 관한 연구)

  • Park Kyoung-Suk;Heo Hyung-Seok;Park Se-Jong;Son Sung-Man;Kim Dong-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.125-131
    • /
    • 2006
  • Recently air pollution has become an important issue. So, as tile number of vehicles increases, the noise pollution has become one of the most serious social issues nowadays. It is a muffler, which is one of the vehicle components. that has the hugest impact on the noise from the vehicle. And it also has a direct influence on the engine performance. So lately the research is proceeding on tile semi-active muffler which can control the back pressure variably by setting up the exhaust variable valve in the baffle to improve its internal structure. The inner parts of muffler which consist of a baffle, pipes and etc. appear to have the complicated turbulence phenomena by the pulsational wave of an unsteady state in the engine and by the structural characteristics of the inner parts. To analyze these phenomena, it is required to have an analysis of its constant quantity and quality. Therefore this study is to analyze with PIV measurement which can analyze the time and space variables, not with the point measurement method like former multi-point anemometer. It is to suggest proper design variables which need to make internal structure of the muffler improve though comparison between the passive type muffler and the semi-active muffler by fabricating a muffler which can be visualized.

On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002 (지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징)

  • Kim C.-H;Park I.-S;Lee S.-J;Kim J.-S;Jin H.-A;Sung H.-G
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

Study On The Heavy Metal Pollution in Soils and Barks of Roadside Trees in Taejon (대전시의 가로수 수피 및 표사의 중금속 오염에 관한 연구)

  • O, In-Hye
    • The Journal of Natural Sciences
    • /
    • v.5 no.2
    • /
    • pp.19-24
    • /
    • 1992
  • To find out the extent of air pollution in Taejon city, we investigated the concents of heavy metals in barks of trees in principal roadside, the outer block of a roadside and Pomunsan Park. Among the road-side trees in these areas, Platanus orientalis, Ginkgo biloba and Liriodendron tulipifera have been chosen. And we analyzed the relationship between the content of heavy metal of the barks and the traffic volume expressed by cars passing through for an hour. The range of contents of the lead in barks of the trees in the roadside and Pomunsan Park were respectively 2-1109 ppm and 5-11 ppm. Generally the contents of lead of barks of the trees in roadside was much higher than that in Pomunsan Park. And there has been positive correlation between the traf-fic volume and the content of lead in the barks. The more cars passing through for an hour, the higher the maximum in contents of lead in the barks of roadside trees. By the way the contents of cadmium in barks of the roadside trees was slightly higher than that in Pomunsan Park and was little variable.

  • PDF

A Study on the Assessment of Pollution Level of Precipitation at Kangwha, 1992 (江華地域 降水의 汚染度 評價에 關한 硏究)

  • 강공언;강병욱;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.57-68
    • /
    • 1995
  • Precipitation samples were collected by a wet-only automatic acid precipitation sampler at Kangwha island on the western coast in Korea, through January until December 1992. pH, electric conductivity and the concentrations of major water-soluble ion components such as N $H_{4}$$^{+}$, $Ca^{2+}$, $K^{+}$, $Mg^{2+}$, N $a^{+}$, N $O_{3}$$^{[-10]}$ , S $O_{4}$$^{2-}$ and C $l^{[-10]}$ were measured. From the result of checking the validity for assesment of pollution level of precipitation samples by pH using correlation analysis between pH and major components, and t-test of chemical composition between acid rain and non-acid rain, pH proved to be not satisfactory for its pillution level. A more comprehensive method is therefore required. In order to estimate the monthly analytical result of chemical composition of precipitation samples comprehensively, a cluster analysis was used among the various multivariate statistical analysis. As a result of making a cluster analysis for separating the monthly precipitation samples into homogeneous patterns by setting the concentrations of nine major water-soluble ion components as a variable, three homogeneous patterns were obtained. The first pattern was a group of months having average ion concentrations, the second a guoup of months having low ion concentration, and the third a group of months having high ion concentrations. Thus, it was indicated that the pollution level of precipitation was higher on February and lower on May, June, August and September than the other months. As a result, this analysis method could be estimated the chemical coposition of precipitation regionally as well as monthly.monthly.

  • PDF

Runoff Characteristics of NPS Pollution on Field in Rainy Season (강우시 밭의 비점오염물질 유출 특성)

  • Won, Chul-hee;Choi, Yong-hun;Shin, Min-hwan;Shin, Dong-suk;Kang, Dong-Gu;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.572-579
    • /
    • 2011
  • We have examined the runoff characteristics of nonpoint source (NPS) in fields. Two monitoring sites were equipped with an automatic velocity meter and water sampler. Monitoring was conducted at fields 1 and field 2 during the rainfall event. Ten rainfall-runoff events were monitored and analyzed during the study period. The results show that runoff occurred if daily rainfall and intensity were higher than 40 mm and 1.6 mm/hr except a few extreme rainfall events with very high intensity. Runoff of field 1 was approximately twice of that of field 2. Event mean concentrations (EMC) and pollution load of analyzed water quality indices were also higher in field 2 than in field 1. Especially, TN load from field 2 was $75.4 mg/m^2$ and was about 5 times higher than that from field 1. Analysis of Pearson correlation coefficient of water quality parameter indicates that besides of TN all items in fields 1 have tight relationship respectively (p < 0.01). But those of fields 2 have a significant (p < 0.05). Estimating units loading of NPS, we suggested that variable such as soil texture, rainfall amount and intensity and slope were needed to be considered from agricultural landuses. The results of this study can be used as a basic data in the development and implementation of total maximum daily loads (TMDL) in Korea.