• Title/Summary/Keyword: Pollution level

Search Result 1,385, Processing Time 0.04 seconds

A Study of Potential Buyers' Consciousness of Single-Family Housing in Ulsan (단독주택에 대한 울산시 거주자의 주의식 연구)

  • Kim, Ji-Suk;Yang, Se-Hwa
    • Journal of Families and Better Life
    • /
    • v.28 no.6
    • /
    • pp.35-46
    • /
    • 2010
  • The purpose of the study was to identify the potential buyers' consciousness of single-family housing to provide useful data to help future single-family housing supplies in Ulsan. The study selected residents in Ulsan, who were over twenty and had an interest in living in a single-family housing. A survey was conducted from September 11, 2008 to September 25, 2008. The sample consisted of 364 persons who are currently live in Ulsan metropolitan area. The results are as following. About two thirds of the sample had the desire to live in a single-family housing. Moving into a single-family housing had financial preparation as the greatest issue. When moving into a single-family housing, the convenience of the residential district was the greatest consideration, whether or not it is a green environment, pollution level, etc. The potential buyers valued environment-friendly features and also had a very strong desire to own their own house. Many of them wanted to design and build their own single-family housing within a budget of 100-200 million KRW. In terms of the location, there was a higher preference for the riverside or lakeside rural areas outside the city. In terms of size, the preference was less than $330m^2$, which includes $99-132m^2$ for residential. When considering a single-family housing the direction was the most important feature, along with eco-friendly and safer materials and equipments. When building the single-family housing the potential buyers considered the community spaces first with a preference for having three bedrooms and two bathrooms. For the exterior, they wanted a unique shape of roof and there were high preferences for brown and beige colors. In terms of housing complexes, the potential buyers preferred individual unit types over complexes. If they preferred housing complexes, they wanted the cluster form complex with about 10-30 units. The complex also required a park-like setting with a guard system, which shows that convenience and safety were the most important features. In terms of complex management, they considered environmental management as the most important feature. The potential buyers were willing to pay belw 200,000 KRW, which showed their desire to minimize financial burdens.

Absorption of Copper(Cu) by Vegetation on Reservoir Sediment Exposed after Drawdown (저수위시 노출된 저수지 저니 상의 식생과 구리(Cu)의 흡수)

  • 이충우;차영일
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.123-133
    • /
    • 1993
  • Shingal reservoir is a relatively small (211ha) and shallow impoundment, and approximately 25 ha of its sediment is exposed after spring drawdown. At least 14 vascular p13n1 species germinate on the exposed sediment, but Persimria vulgaris Webb et Moq. quickly dominates the vegetation. In order to estimate the role of the vegetation in the dynamics of heavy metal pollutants in the reservoir, Cu concentration of water, fallout particles, exposed sediment, and tissues of p. vulgaris, Ivas analyzed. Cu content in reservoir water decreased from $13.10mg/m^2$ on May 15 (before dralvdown) to $3.08mg/m^2$ in June 1 (after drawdown), mainly due to the loiwering of water level. Average atmospheric deposition of Cu by fallout particles was $10.84 {\mu}g/m^2/day$. Cu content in the surface 15cm of exposed sediment decreased from $5.094g1m^2$ right after drawdown, to $0.530g/m^2$ in 41 days, which is a 89.6% decrease. Therefore up to 99.7% of Cu in the reservoir appears to exist in the sediment. only 0.3% in water If the rate of atmospheric Input by fallout particles is assumed to have been the same since 1958, when the reservoir was completed, cumulative input of Cu during the 38 years would have been $150.35mg/m^2$, which is only 3.0% of Cu content in sediment right after drawdown. Therefore, most of Cu in the Shingal reservoir must have been transported by the Shingal-chun flowing into the reservoir, Standing crop of vegetation on the exposed sediment 41 days after drawdown was $730.67g/m^2$, of which 630.91g/m2 was p. vulgaris alone, and Cu content in P vulgaris at this time was $6.612mg/m^2$. This was only 0.13% of Cu in the exposed sediment, but was 50.5% of Cu in water before drawdown, or 167% of the average annual input of Cu by atmospheric deposition. If other plants were assumed to absorb Cu to the same concentration as p. vulgaris, total amount of Cu absorbed in 41 days by vegetation on the exposed sediment is estimated to be 1913.3 g, which is a considerable contribution to the purification of the reservoir water.

  • PDF

A Pilot Study on Emission Analysis of Air Pollutants Produced from Portable Recycling of Asphalt Concrete (간이이동법에 의한 폐아스콘 재생시 대기오염물의 배출분석에 대한 실험적 연구)

  • Lee, Byeong-Kyu;Kim, Haeng-Ah;Jeong, Ui-Ryang;Duong, Trang;Chae, Po-Gi;Park, Kyung-Won
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.385-392
    • /
    • 2007
  • Currently, portable equipment for recycling of waste asphalt concrete (ASCON) has been used. However, any air pollution control devices are not attached in the simple portable one. Thus, a lot of air pollutants have been produced from recycling processes of waste ASCON which resulted from aging of paved roads or repavement of roads. This study deals with a preliminary result of concentration analysis of air pollutants obtained from a pilot and a real recycling processes of waste ASCON using simple portable recycling equipment. Air pollutants were taken from 4 steps of the pilot recycling process including an initial heating by liquid petroleum gas (LPG), intermediate heating and melting (H&M) process, final H&M process, and pavement processes using recycled ASCON at the recycling site. Also, air pollutants were taken front 4 steps of the real recycling processes including an initial H&M, final H&M and mixing, loading of recycled ASCON to dump trucks, and at the recycling site after leaving the loaded dump trucks for real pavement sites. The air pollutants measured in this study include volatile organic compounds (VOCs), aldehydes, particulate matter (PM: PM1, PM2.5, PM7, PM10, TSP (total suspended particulate)). The identified concentrations of VOCs increased with increasing time or degree for H&M of waste ASCON. In particular, very high concentrations of the VOCs at the status of complete melting, which is exposed to the air, of the waste ASCON just before paving tv the recycled ASCON at the recycling site. Also, considerable amount of VOCs were identified from the recycling equipment after the dump trucks leaded by recycled ASCON leaved the recycling site for the pavement sites. The relative level of formaldehyde exceeded 80% of the aldehydes Identified in the recycling processes. This is because the waste ASCON is exposed to direct flame of LPG during H&M processes. The PM concentrations measured in the winter recycling processes, such as the loading and rotation processes of waste ASCON into/in the recycling equipment for H&M, were much higher than those in the summer ones. In particular, the concentrations of coarse particles such as PM7 and PM10 during the winter recycling were very high as compared those during the summer one.

Meteorological Characteristics of High-Ozone Episode Days in Daegu, Korea (대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성)

  • Son, Im-Young;Kim, Hee-Jong;Yoon, Ill-Hee
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.424-435
    • /
    • 2002
  • This study analyzes the surface ozone and meteorological data in Daegu for a period from 1997 to 1999. It also investigates the meteorological characteristics of high ozone episodes. For this study the high ozone episode has been defined as a daily maximum ozone concentration higher than 100ppb in at least one station among six air quality monitoring stations in Daegu, Korea. The frequency of episodes is 13 days. The frequency is the highest in May and September. The average value of daily maximum ozone concentration is 81.6ppb, and 8-hour average ozone concentration is 58.6ppb for the high episodes. This shows that ozone pollution is continuous and wide-ranging in Daegu. The daily maximum ozone concentration is positively correlated to solar radiation and daily maximum temperature, but negatively correlated to relative humidity, wind speed and cloud amount. The maximal correlation coefficient to solar radiation is 0.45. The differences between high ozone episode day's daily mean meteorological value and monthly mean value are +1.58hPa for sea level pressure, +3.45${\circ}$C for maximum temperature, -5.69% for relative humidity, -0.46ms$^{-1}$ for wind speed, -1.79 for cloud amount, and +3.97MJm$^{-2}$ for solar radiation, respectively. This shows that strong solar radiation, low wind speed and no precipitation between 0700${\sim}$1100LST are favorite conditions for high ozone episodes. It is related to the morning stagnant condition.

Evaluation of Beach Pollution by Aquaculture Styrofoam Buoys in Tongyeong, Korea (양식장 스티로폼 부자쓰레기로 인한 통영 해변의 오염 평가)

  • Hong, Su Yeon;Lee, Chan Won;Hong, Sunwook;Lee, Jongmyoung;Jang, Yong Chang
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.104-115
    • /
    • 2014
  • Abundance and composition of marine debris on 13 beaches of Tongyeong City, South Korea were surveyed in 2013 Autumn. The average quantity of macro debris (>25 mm) was about 30 particle/$m^2$ and that of micro debris (1 mm-25 mm) was about 26,971 particle/$m^2$. This is a very high level compared with other areas of South Korea and the other countries. Among the 7 material types of debris (styrofoam, hard plastic, fiber, metal, glass, wood and others), styrofoam composed a large portion: 75% of macro debris and 98% of micro debris. And among the 'whole' styrofoam debris items whose original volume is remained more than 50%, styrofoam buoy debris composed 93%. This result suggests that the beaches surveyed are seriously contaminated by marine debris, and most of its sources are aquaculture styrofoam buoys. Management of styrofoam buoy debris used for oyster aquaculture in Tongyeong City is important not only for Tongyeong city, but also for other areas, because Tongyeong city hosts the biggest number of oyster aquaculture areas in South Korea.

Absorption of Copper(Cu) by Vegetation on Reservoir Sediment Exposed after Drawdown (저수위시 노출된 저수지 저니 상의 식생과 구리(Cu)의 흡수)

  • Lee, Chung-U;Cha, Yeong-Il
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.29-29
    • /
    • 1993
  • Shingal reservoir is a relatively small (211ha) and shallow impoundment, and approximately 25 ha of its sediment is exposed after spring drawdown. At least 14 vascular p13n1 species germinate on the exposed sediment, but Persimria vulgaris Webb et Moq. quickly dominates the vegetation. In order to estimate the role of the vegetation in the dynamics of heavy metal pollutants in the reservoir, Cu concentration of water, fallout particles, exposed sediment, and tissues of p. vulgaris, Ivas analyzed. Cu content in reservoir water decreased from $13.10mg/m^2$ on May 15 (before dralvdown) to $3.08mg/m^2$ in June 1 (after drawdown), mainly due to the loiwering of water level. Average atmospheric deposition of Cu by fallout particles was $10.84 {\mu}g/m^2/day$. Cu content in the surface 15cm of exposed sediment decreased from $5.094g1m^2$ right after drawdown, to $0.530g/m^2$ in 41 days, which is a 89.6% decrease. Therefore up to 99.7% of Cu in the reservoir appears to exist in the sediment. only 0.3% in water If the rate of atmospheric Input by fallout particles is assumed to have been the same since 1958, when the reservoir was completed, cumulative input of Cu during the 38 years would have been $150.35mg/m^2$, which is only 3.0% of Cu content in sediment right after drawdown. Therefore, most of Cu in the Shingal reservoir must have been transported by the Shingal-chun flowing into the reservoir, Standing crop of vegetation on the exposed sediment 41 days after drawdown was $730.67g/m^2$, of which 630.91g/m2 was p. vulgaris alone, and Cu content in P vulgaris at this time was $6.612mg/m^2$. This was only 0.13% of Cu in the exposed sediment, but was 50.5% of Cu in water before drawdown, or 167% of the average annual input of Cu by atmospheric deposition. If other plants were assumed to absorb Cu to the same concentration as p. vulgaris, total amount of Cu absorbed in 41 days by vegetation on the exposed sediment is estimated to be 1913.3 g, which is a considerable contribution to the purification of the reservoir water.

Detection of Enterococci and their Vancomycin Resistance in Drinking Spring-Water (먹는물 약수터 장구균의 검출 특성과 반코마이신 내성 현황)

  • Yoon, Tae-Ho;Lee, Hyang;Lee, Seung-Joo;Yeo, In-Hak;Eom, Seok-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.979-985
    • /
    • 2010
  • This study was performed to detect enterococci strain as an indicator of faecal contamination, to identify of 16S rDNA sequence and vancomycin resistance by MIC (Minimum Inhibitory Concentration) test from drinking spring-water samples in Seoul. The detection frequency of enterococci was 42 (19.8%) among 212 samples, and its concentration was ranged from 0 to 110 CFU/100 mL. These results were confirmed the possibility as an indicator microorganisms that similar to the frequency of E. coli detection (t test p-value 0.268, significant level 0.05). Isolated 56 enterococci samples were identified by 16S rDNA sequence data and their NCBI BLAST searching. They were identified to Enterococcus faecalis of 24 samples, E. faecium (10), E. casseliflavus (10), E. gallinarum (3), E. hirae (2), E. durans (2), E. sanguinicola (1). E. faecalis was dominant species that clinical case report of a domestic was similar. Vancomycin resistant enterococci (VRE) of 53 samples showed that vanB and vanC1/C2 type with 2 and 12 case, respectively. These results indicated that the drinking spring-water quarantined to fecal pollution for block out outbreak of gastrointestinal symptom with using such as disinfection process.

Characteristics of Temporal Variation on Water Quality (T-P, T-N, CODMn, SS, BOD5) in the Jungrang Stream during Rainfall Event (강우 시 중랑천 유역의 수질(T-P, T-N, CODMn, SS, BOD5)변화 특성)

  • Jung, Jaehyung;Zhou, Xing;Lee, Taejin;Kwon, O-Yul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.412-420
    • /
    • 2014
  • Water quality variations were investigated at 4 locations of Jungrang river (upper, middle and lower basins) during a period of 3 rainfall events. During the rainfall, concentrations of $COD_{Mn}$, SS and $BOD_5$ significantly increased, while the concentration of T-N decreased and that of T-P remained relatively constant. This pattern became more apparent as the level of accumulative precipitation and rainfall intensity increased. Simple regression analysis showed that the accumulative precipitation was positively correlated with all water quality pollutants except for T-N. With increasing accumulative precipitation, the concentration of T-N decreased, while the others increased. $R^2$ of simple regressions of hourly average rainfall intensity and water quality pollutants, showed wider range of variation ranged from 0.483 to 0.992, which indicated a strong correlation. The stronger the hourly average rainfall intensity, the more T-N and T-P in the upper basin, more $COD_{Mn}$ in the middle and lower basins, more SS with gradual increase from upper to lower areas, and more $BOD_5$ with gradual decrease from upper to lower region. Simple regression showed that water quality pollution in the upper basin was more sensitive to an increase of rainfall discharge than that in the middle and lower areas.

The Study for Estimating Traffic Volumes on Urban Roads Using Spatial Statistic and Navigation Data (공간통계기법과 내비게이션 자료를 활용한 도시부 도로 교통량 추정연구)

  • HONG, Dahee;KIM, Jinho;JANG, Doogik;LEE, Taewoo
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.3
    • /
    • pp.220-233
    • /
    • 2017
  • Traffic volumes are fundamental data widely used in various traffic analysis, such as origin-and-destination establishment, total traveled kilometer distance calculation, congestion evaluation, and so on. The low number of links collecting the traffic-volume data in a large urban highway network has weakened the quality of the analyses in practice. This study proposes a method to estimate the traffic volume data on a highway link where no collection device is available by introducing a spatial statistic technique with (1) the traffic-volume data from TOPIS, and National Transport Information Center in the Ministry of Land, Infrastructure, and (2) the navigation data from private navigation. Two different component models were prepared for the interrupted and the uninterrupted flows respectively, due to their different traffic-flow characteristics: the piecewise constant function and the regression kriging. The comparison of the traffic volumes estimated by the proposed method against the ones counted in the field showed that the level of error includes 6.26% in MAPE and 5,410 in RMSE, and thus the prediction error is 20.3% in MAPE.

Distributional characteristics of Escherichia coli based on seasonal rainfall variations and extension of freshwater pollutant sources by salinity gradients at Ulsan Bay of Korea facing East Sea (동해 울산만에서 계절적 강우변화와 담수기원 오염원이 염분구배 및 유역별 대장균 분포에 미치는 영향)

  • Lee, Minji;Baek, Seung Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.632-640
    • /
    • 2017
  • In order to understand the seasonal and geographical characteristics of environmental factors and distribution of Escherichia coli by salinity gradient due to precipitation, we investigated abiotic and biotic factors during four seasons from February 2013 to November 2015. The study area was divided into three different zones based on salinity gradient and geo-oceanographic characteristics. During the study period, water temperature, salinity, Chlorophyll a, and secchi-depth varied in the range of $8.5-26.1^{\circ}C$, 13.5-34.4 psu, $0.4-74.0{\mu}g\;L^{-1}$, and 0.5-10.0 m, respectively. Salinity was low at Zone I, which was influenced by water flux from Tae-hwa River, especially in 2014. Salinity was gradually increased (one-way ANOVA; p < 0.05) toward Zone III located offshore of the bay. The highest colony form of E. coli was detected at Zone I. E. coli maintained a relatively low level at Zone III during all seasons. E. coli was correlated with transparency (r = -0.36; p < 0.05) and salinity (r = -0.53; p < 0.01), implying that those parameters might play important roles in the proliferation of E. coli. These results indicated that E. coli were strongly affected by frequent rain (< 50 mm) around inner stations in Ulsan Bay of Korea.