• Title/Summary/Keyword: Pollution flow

Search Result 813, Processing Time 0.025 seconds

Comparative analysis of auto-calibration methods using QUAL2Kw and assessment on the water quality management alternatives for Sum River (QUAL2Kw 모형을 이용한 자동보정 방법 비교분석과 섬강의 수질관리 대안 평가)

  • Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.5
    • /
    • pp.345-356
    • /
    • 2016
  • In this study, auto-calibration method for water quality model was compared and analyzed using QUAL2Kw, which can estimate the optimum parameters through the integration of genetic algorithm and QUAL2K. The QUAL2Kw was applied to the Sum River which is greatly affected by the pollution loads of Wonju city. Two auto-calibration methods were examined: single parameter application for the whole river reach and separate parameter application for each reach of multiple reaches. The analysis about CV(RMSE) and fitness of the GA show that the separate parameter auto-calibration method is better than the single parameter method in the degree of precision. Thus the separate parameter auto-calibration method is applied to the water quality modelling of this study. The calibrated QUAL2Kw was used for the three scenarios for the water quality management of the Sum River, and the water quality impact on the river was analyzed. In scenario 1, which improve the effluent water quality of Wonju WWTP, BOD and TP concentrations of the Sum River 4-1 station which is representative one of Mid-Watershed, are decreased 17.7% and 29.1%, respectively. And immediately after joining the Wonjucheon, BOD and TP concentrations are decreased 50.4% and 40.5%, respectively. In scenario 2, Wonju water supply intake is closed and multi-regional water supply, which come from other watershed except the Sum River, is provided. The Sum River water quality in scenario 2 is slightly improved as the flow of the river is increased. Immediately after joining the Wonjucheon, BOD and TP concentrations are decreased 0.18mg/L and 0.0063mg/L, respectively. In scenario 3, the water quality management alternatives of scenario 1 and 2 are planned simultaneously, the Sum River water quality is slightly more improved than scenario 1. Water quality prediction of the three scenarios indicates that effluent water quality improvement of Wonju WWTP is the most efficient alternative in water quality management of the Sum River. Particularly the Sum River water quality immediately after joining the Wonjucheon is greatly improved. When Wonju water supply intake is closed and multi-regional water supply is provided, the Sum River water quality is slightly improved.

Volatilization of Sprayed Pesticides in Greenhouse using a Lysimeter (라이시미터를 이용한 시설하우스 내에 살포한 농약의 휘산 양상)

  • Kim, Danbi;Kim, Taek-Kyum;Kwon, HyeYong;Hong, Su-Myeong;Park, Byung-Jun;Lim, Sung-Jin;Lee, Hyo-Sub;Moon, Byeong-Cheol
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.4
    • /
    • pp.305-311
    • /
    • 2016
  • In cultivation environment, various pesticides are used and some of them could be volatilized into the air. This could affect farmer's health and also cause environmental pollution. This study was carried out to investigate the volatilization of pesticides, and use the reference data for preventing farmer's pesticide intoxication and securing worker safety. The experiment was conducted in a greenhouse using a lysimeter which was of $1m^2$ area and 1.5 m depth filled with upland soil. The pesticides treated in lysimeter soil were ethoprophos (5.0% GR), diazinon (34.0% EC), alachlor (43.7% EC), metolachlor (40.0% EC), chlorpyrifos (2.0% GR), pendimethalin (31.7% EC), carbaryl (50.0% WP), napropamide (50% WP), tebuconazole (25.0% WP) and imidacloprid (2.0% GR). Each pesticide was treated at a concentration of 770.5 mg based on A.I (%). The recovery of pesticide ranged from 77.4 to 99.3%. The volatilized pesticides in air were collected by personal air sampler with PUF tube at 4 l/min flow rate. In addition, temperature and humidity were measured. The collected samples were extracted using acetone in a soxhlet apparatus for 8 hours. The extracted pesticides were resoluted with acetonitrile and diluted 5 times. It was analyzed with LC-MS/MS. For 720 hours experiment, the largest vaporization amount of each pesticide in air was ethoprophos $15.24{\mu}g/m^3$, diazinon $5.14{\mu}g/m^3$, pendimethalin $2.70{\mu}g/m^3$, chlorpyrifos $1.76{\mu}g/m^3$, alachlor $1.40{\mu}g/m^3$, metolachlor $1.12{\mu}g/m^3$, carbaryl $0.27{\mu}g/m^3$, napropamide $0.22{\mu}g/m^3$, tebuconazole $0.11{\mu}g/m^3$ and imidacloprid $0.05{\mu}g/m^3$. The R value (coefficient of correlation) between volatilization and vapor pressure of pesticides is higher than 0.99. Therefore, there is high correlation between volatilization and vapor pressure of pesticides.

Use of Tributary Water Quality and Flowrate Monitoring Data for Effective Implementation of TMDL (수질오염총량관리제의 효율적인 시행을 위한 지류하천 수질.유량모니터링 자료의 활용)

  • Kim, Young-Il;Jeong, Woo-Hyeok;Kim, Hong-Su;Yi, Sang-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.119-125
    • /
    • 2012
  • The tributary water quality and flowrate monitoring result, which is fundamental data for the establishment of the water environmental policy, is used as very important data for the implementation of TMDL. This study introduced how to use the tributary water quality and flowrate monitoring data for the analysis of the watersheds, the satisfactory assessment of water quality standards in the watersheds, the selection of watersheds for the establishment of the implementation plan, and the selection of the tributary catchments for improving the water quality using a stream grouping method. According to the analytical results of tributary catchment using water quality and flowrate monitoring data of thirty-seven tributaries in the Geum-River watershed at Chungcheongnam-do, the value of flowrate in the tributaries, which is located in the middle-lower Geum-River watershed, was greater than the other areas and the concentration of the water pollutants regardless of water quality parameters in the tributaries at Nonsancheon catchment was relatively higher than the other areas. The problems, which have the determination of satisfaction of water quality standards and selection of target watersheds for establishment of the implementation plan regardless of the water quality of tributary in the watershed due to the water quality and flowrate monitoring results of the main river, were improved use of the results of tributary water quality and flowrate monitoring. Also, the tributary catchments for improving the water quality, according to stream grouping method based on the results of tributary water quality and flowrate monitoring, were selected. In the Geum-River watershed at Chungcheongnam-do, the tributary in the Nonsancheon, Byeongcheoncheon, Seokseongcheon, Jocheon catchments, which has a large flow and a high concentration of water pollutants, should be preferentially selected for improving the water quality of the tributary in accordance with the reduction of the source of pollution.

Pollutant Loading Estimate from Yongdam Watershed Using BASINS/HSPF (BASINS/HSPF를 이용한 용담댐 유역의 오염부하량 산정)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.187-197
    • /
    • 2006
  • A mathematical modeling program called Hydrological Simulation Program-FORTRAN (HSPF) developed by the United States Environmental Protection Agency(EPA) was applied to the Yongdam Watershed to examine its applicability for loading estimates in watershed scale. It was run under BASINS (Better Assessment Science for Integrating point and Nonpoint Sources) program, and the model was validated using monitoring data of 2002 ${\sim}$ 2003. The model efficiency of runoff was high in comparison between simulated and observed data, while it was relatively low in the water quality parameters. But its reliability and performance were within the expectation considering complexity of the watershed and pollutant sources and land uses intermixed in the watershed. The estimated pollutant load from Yongdam watershed for BOD, T-N and T-P was 1,290,804 kg $yr{-1}$, 3,753,750 kg $yr{-1}$ and 77,404 kg $yr{-1}$,respectively. Non-point source (NPS) contribution was high showing BOD 57.2%, T-N 92.0% and T-P 60.2% of the total annual loading in the study area. The NPS loading during the monsoon rainy season (June to September) was about 55 ${\sim}$ 72% of total NPS loading, and runoff volume was also in a similar rate (69%). However, water quality was not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. Overall, the BASINS/HSPF was applied to the Yongdam watershed successfully without difficulty, and it was found that the model could be used conveniently to assess watershed characteristics and to estimate pollutant loading in watershed scale.

The physical geography in general:yesterday and tomorrow (자연지리학 일반: 회고와 전망)

  • Son, Ill
    • Journal of the Korean Geographical Society
    • /
    • v.31 no.2
    • /
    • pp.138-159
    • /
    • 1996
  • There has been a tendency for Geomorphology and Climatology to be dominant in Physical Geography for 50 years in Korea. Physical Geography is concerned with the study of the totality of natural environment through the integrated approaches. But, an overall direction or a certain paradigm could not be found, because major sub-divisions of Physical Geography have been studied individually and the subjects and the approaches in studying Physical Geography are enormously diverse. A consensus of opinion could not also exist in deciding what kind of the sub-divisions should be included in the physical geography in general and how those should be summarized. Furthermore it would be considered imprudent to survey the studies of Physical Geography besides those of Geomorphology and Climatology due to the small number of researchers. Assuming that the rest of Physical Geographical studies with the exception of Geomorphological and Climatological studies are the Physical Geography in general, the studies of Physical Geogrpahy in general are summarized and several aspects are drown out as follows. First the descliption of all possible factors of natural environments was the pattern of early studies of Physical Geography and the tendency is maintained in the various kinds of research and project reports. Recently Physical Geographers have published several introductory textbooks or research monographs. In those books, however, the integrated approaches to Physical Geography were not suggested and the relationship between man and nature are dealt with in the elementary level. Second, the authentic soil studies of Physical Geographers are insignificant, because the studies of soil in Physical Geography have been mostly considered as the subsidiary means of Geomorphology Summarizing the studies of Soil Gegraphy by physical geographers and other Pedologists, the subjects are classified as soil-forming processes, soil erosions, soil in the tidal flat and reclaimed land, and soil pollution. Physical Geographers have focused upon the soil-forming processes in order to elucidate the geomorphic processes and the past climatic environment. The results of other subjects are trifling. Thirdy Byogeygrayhers and the results of studies are extremely of small number and the studies of Biogeography in Korea lines in the starting point. But, Biogeography could be a more unifying theme for the Physical-human Geography interface, and it would be expected to play an active part in the field of environmental conservation and resource management. Forth, the studies of Hydrogeography (Geographical Hydrology) in Korea have run through the studies of water balance and the morphometric studies such as the drainage network analysis and the relations of various kinds of morphometric elements in river. Recently, the hydrological model have introduced and developed to predict the flow of sediment, discharge, and ground water. The growth of groundwater studies is worthy of close attention. Finally, the studies on environmental problems was no mole than the general description about environmental destruction, resource development, environmental conservation, etc. until 1970s. The ecological perspectives on the relationship between man and nature were suggested in some studies of natural hazard. The new environmentalism having been introduced since 1980s. Human geographers have lead the studies of Environmental Perception. Environmental Ethics, Environmental Sociology, environmental policy. The Physical geographers have stay out of phase with the climate of the time and concentrate upon the publication of introductory textbooks. Recently, several studies on the human interference and modification of natural environments have been made an attempt in the fields of Geomorphology and climatology. Summarizing the studies of Physical Geography for 50 years in Korea, the integrated approaches inherent in Physical Geography disappeared little by little and the majol sub-divisions of Physical Ceography have develop in connection with the nearby earth sciences such as Geology, Meteorology, Pedology, Biology, Hydrology, etc been rediscovered by non-geographers under the guise of environmental science. It is expected that Physical Geography would revive as the dominant subject to cope with environmental problems, rearming with the innate integrated approaches.

  • PDF

Environmental Geophysical Survey of Abandoned Landfills for Contamination Evaluation: A Case Study (불량 매립지 오염평가를 위한 지구물리 탐사 사례연구)

  • Lee, Sung-Soon;Lee, Jin-Yong;Yoon, Hee-Sung;Lee, Kang-Kun;Kim, Chang-Gyun;Yu, Young-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.463-471
    • /
    • 2006
  • Electrical resistivity surveys were conducted at areas of abandoned landfills in Cheonan and Wonju. Geology and extent of leachate migration around the landfills were evaluated with collected resistivity data by 2-D and 3-D resistivity inverse modeling. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to examine possible pollution at the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system, which has not been in operation. To evaluate leachate leakage into the paddy fields, a total of 4 survey lines were used. According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and the leachate would reach the downgradient paddy fields. Low resistivity area was observed in the old reservoir area and it appeared to be derived from convergence of groundwater flows from the surrounding valley and the moist wet land. In addition, groundwater flow into the paddy fields occurs beneath the old reservoir embankment at depths of $7{\sim}8m$. This paper reports details of the resistivity surveys for the uncontrolled landfills.

Estimation of Total Allowable Pollutant Loads Using Eco-hydrodynamic Modeling for Water Quality Management on the Southern Coast of Korea (생태계 모델에 의한 총허용 오염부하량 산정을 통한 연안해역의 수질관리)

  • Lee, Dae-In;Kim, Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.1
    • /
    • pp.29-43
    • /
    • 2007
  • For effective management of water quality on the southern coast of korea, a three-dimensional eco-hydrodynamic model is used to predict water quality in summer and to estimate the reduction rate in pollutant loads that would be required to restore water quality. Under the current environmental conditions, in particular, pollutant loadings to the study area were very high, chemical oxygen demand (COD) exceeded seawater quality criteria to comply with current legislation, and water quality was in a eutrophic condition. Therefore, we estimated reduction rates of current pollutant loads by modeling. The model reproduced reasonably the flow field and water quality of the study area. If the terrestrial COD, inorganic nitrogen and phosphorus loads were reduced by 90%, the water quality criteria of Region A were still not satisfied. However, when the nutrient loads from polluted sediment and land were each reduced by 70% simultaneously, COD and $Chl-{\alpha}$ were restored. When we reduced the input COD and nutrient loads from the Nakdong River by 80%, $Chl-{\alpha}$ and COD of Region B decreased below $10\;{\mu}g\;1^{-1}$ and $2\;mg\;1^{-1}$, respectively. The water quality criteria of Region C were satisfied when we reduced the terrestrial COD and nutrient loads by 70%. Total allowable loadings of COD and inorganic nutrients in each region were determined by multiplying the reduction rates by current pollutant loads. Estimated high reduction rates, although difficult to achieve at the present time under the prevailing environmental conditions, suggest that water pollution is very severe in this study area, and pollutant loads must be reduced within total allowable loads by continuous and long-term management. To achieve the reduction in pollutant loads, sustainable countermeasures are necessary, including the expansion of sewage and wastewater facilities, polluted sediment control and limited land use.

  • PDF

The Behavior of Dissolved and Particulate Phases of Trace Elements within the Watershed of Juam Reservoir (주암호 집수유역 내 용존 및 입자상 미량원소의 거동 특성)

  • Lee, Pyeong-Koo;Chi, Se-Jung;Youm, Seung-Jun
    • Economic and Environmental Geology
    • /
    • v.41 no.4
    • /
    • pp.405-425
    • /
    • 2008
  • In order to investigate the amounts of trace elements flowing into reservoir, and to elucidate the relationship between trace element mobility and fraction size, the stream water and sediment samples were collected from thirty-two sites of the 3rd or 4th order stream within watershed surrounding the Juam reservoir. Chemical analyses of trace elements (As, Cd, Cr, Cu, Ni, Pb and Zn) for all samples were completed, and additionally cationi and anion for stream water samples. Considering the distribution of rocks and contamination sources in watershed, the eight stream sediments were selected from typical sites representing study areas, and we determined the concentrations of trace elements according to size fractions ($2\;mm{\sim}200\;{\mu}m$, $200{\sim}100\;{\mu}m$, $100{\sim}50\;{\mu}m$, $50{\sim}20\;{\mu}m$ and < $20\;{\mu}m$). The correlation relationships between concentrations and size fractions of stream sediments were important to identify the hydro-geochemical behavior of trace elements that flow into Juam reservoir. Stream waters showed four water types (Ca-Mg-$HCO_3$, Ca-Na-$HCO_3$-Cl, Ca-Na-$HCO_3-SO_4$, Ca-Na-$HCO_3$) depending on pollution sources such as coal mine, metal mine, farm-land and dwellings. Concentrations of trace elements increased clearly with the decrease in size fractions of stream sediments. Concentrations of Cu, Pb and Zn increased dramatically in silt size (< $20\;{\mu}m$) fraction, while As had high concentrations in sand size ($2\;mm{\sim}100\;{\mu}m$) fraction in downstream sediments of metal mines. These indicate that Cu, Zn, and Pb moved into Juam reservoir easily in the adsorbed form on silt size grain in sediments, and As was transported as As-bearing mineral facies, resulting in its less chance to reach into Juam reservoir.

A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay (마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구)

  • Kim, Gweon-Su;Ryu, Ha-Sang;Kim, Kang-Min
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.637-645
    • /
    • 2013
  • Masan bay with a semi-enclosed waters has serious water quality problems due to the low flow and river pollution load from land, and shows the vulnerable locational characteristics to storm surge. We are seeking the way of both operating disaster prevention facilities and water quality improvement measures in the bay. That is, the water was exchanged using the head difference occurred by operating disaster prevention facilities. The location of disaster prevention facilities was assumed to be in the inlet of the bay, in the vicinity of Machang bridge, and in the vicinity of Dot island and the operation time was assumed to be early morning hours(01~05) considering the number of shipping passage and annual tide, and spring tide of the largest head difference. In addition, the experiment case of water exchange including the in-outflow feeder pipe was tested. According to the simulation results, water exchange rate in all experiments has shown a steady increase. Water exchange rate of the whole of Masan bay in the case of present is 38.62%. The water exchange rate of the inside of Masan bay compared with the inlet of bay, appeared to be very low. Thus, we judged that the characteristics of semi-enclosed waters were well reproduced. On the results of the experiment of disaster prevention facilities and in-outflow feeder pipe, the case of the operation of disaster prevention facilities, water exchage rate is high compared with the case of present. And, the higer the operating frequency, the more water exchange is appeared. The cases of water exchange prevention facilities through the in-outflow feeder pipe caused by the head difference, also showed the higest improvement of the water quality. Compared with the south of Machang bridge, the effect of water exchange was better in the inlet of Masan bay and Dot island. On the other hand, the inlet of Masan bay is higer than Dot island as for water exchange of the whole of Masan bay, but opposite, water change rate including Masan inside was higher in the case of Dot island.

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.