• 제목/요약/키워드: Pollution detection

검색결과 201건 처리시간 0.024초

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

보조기구의 형상 변경에 따른 배기계에서의 압력 변동 분석 (The Analysis of the Pressure Fluctuation in the Exhaust System According to the Assistant Device Configuration)

  • 정성원;심국상
    • 한국산업융합학회 논문집
    • /
    • 제6권4호
    • /
    • pp.325-331
    • /
    • 2003
  • This paper described the characteristics of the exhaust pressure and proposed the assistant device for detection of misfired cylinder. Misfire, one of abnormal combustion, affects a bad influence of the 3-way catalyst and emits unburned hydrocarbon. Therefore, to prevent these unusual phenomena and eliminate the factor of the environmental pollution, early detection and correction of the misfired cylinder play a very important role. The configuration of assistant device was changed by length and diameter of pipe and analyzed with the install position on the exhaust system. Experimental results showed that the configuration of assistant device is not affected more than length and diameter of pipe and the assistant device is be effective in the detection of misfired cylinder on the gasoline engine.

  • PDF

다중가스센서를 이용한 화재의 조기검출에 대한 연구 (A Study on the Early Fire Detection by Using Multi-Gas Sensor)

  • 조시형;장향원;전진욱;최석임;김선규;강종위;최삼진;박찬원
    • 센서학회지
    • /
    • 제23권5호
    • /
    • pp.342-348
    • /
    • 2014
  • This paper introduced a novel multi-gas sensor detector with simple signal processing algorithm. This device was evaluated by investigating the characteristics of combustible materials using fire-generated smell and smoke. Plural sensors including TGS821, TGS2442, and TGS260X were equipped to detect carbon monoxide, hydrogen gas, and gaseous air contaminants which exist in cigarette smoke, respectively. Signal processing algorithm based on the difference of response times in fire-generated gases was implemented with early and accurately fire detection from multiple gas sensing signals. All fire experiments were performed in a virtual fire chamber. The cigarette, cotton fiber, hair, polyester fiber, nylon fiber, paper, and bread were used as a combustible material. This analyzing software and sensor controlling algorithm were embedded into 8-bit micro-controller. Also the detected multiple gas sensor signals were simultaneously transferred to the personnel computer. The results showed that the air pollution detecting sensor could be used as an efficient sensor for a fire detector which showed high sensitivity in volatile organic compounds. The proposed detecting algorithm may give more information to us compared to the conventional method for determining a threshold value. A fire detecting device with a multi-sensor is likely to be a practical and commercial technology, which can be used for domestic and office environment as well as has a comparatively low cost and high efficiency compared to the conventional device.

Biotic ligand model에 근거한 중금속 오염지역의 Pb 및 Cd 위해오염도 평가기법 개발 (Assessment of Risk Based Pollution Level of Pb and Cd in Metal Contaminated Soils Using Biotic Ligand Model)

  • 안진성;정슬기;문희선;남경필
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권4호
    • /
    • pp.23-30
    • /
    • 2011
  • Risk based pollution level of Pb and Cd in metal contaminated soils depending on physicochemical properties of soil in a target site was assessed using biotic ligand model. Heavy metal activity in soil solution defined as exposure activity (EA) was assumed to be toxic to Vibrio fischeri and soil organisms. Predicted effective activity (PEA) determined by biotic ligand model was compared to EA value to calculate risk quotient. Field contaminated soils (n = 10) were collected from a formes area and their risk based pollution levels were assessed in the present study using the calculated risk quotient. Concentrations of Pb determined by aqua regia were 295, 258, and 268 mg/kg in B, H and J points and concentrations of Cd were 4.73 and 6.36 mg/kg in G and I points, respectively. These points exceeded the current soil conservation standards. However, risk based pollution levels of the ten points were not able to be calculated because concentrations of Pb and Cd in soil solution were smaller than detection limits or one (i.e., non toxic). It was because heavy metal activity in soil solution was dominant toxicological form to organisms, not a total heavy metal concentration in soil. In addition, heavy metal toxicity was decreased by competition effect of major cations and formation of complex with dissolved organic carbon in soil solution. Therefore, it is essential to consider site-specific factors affecting bioavailability and toxicity for estimating reliable risk of Pb and Cd.

COMPOSTING AND LAND APPLICATION OF ANIMAL WASTES

  • Harada, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권1호
    • /
    • pp.113-121
    • /
    • 1992
  • An the livestock production in Japan is industrialized, a tremendous amount of animal wastes is being produced annually, resulting in serious environmental pollution problems. Animal wastes could be pollutants, but they are also important sources of fertilizer nutrients and organic matter. Composting is an effective way of promoting the increased utilization of animal wastes. The characterization of maturing process during composting is important in order to improve the composting technology and to develop and efficient method to estimate the degree of maturity. The rise and fall in temperature, and changes in the constituents of the compost, reflect the maturing process and may serve as indicators for maturation. In addition, the detection of nitrate by diphenylamine, the determination of cation-exchange capacity (CEC), and the germination test, are also recommended as the methods of estimating the degree of maturity. The heavy applications of animal manure and compost may cause an adverse effect on soils and crops. When excess manure is applied, the nitrogen will be accumulated in soil, resulting in accumulation of nitrate in crops and pollution of the groundwater. Guidelines for application rates are recommended, to maintain soil productivity and quality of crops, and to prevent the environmental pollution.

Toxic detection in mine water based on proteomic analysis of lysosomal enzymes in Saccharomyces cerevisiae

  • Nguyen, Ngoc-Tu;Kim, Yang-Hoon;Bang, Seung Hyuck;Hong, Ji Hye;Kwon, Soon Dong;Min, Jiho
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.19.1-19.10
    • /
    • 2014
  • Objectives Lysosome is the cell-organelle which is commonly used as biomonitoring tool in environmental pollution. In this study, the lysosomal proteomic of the yeast Saccharomyces cerevisiae was analyzed for utilization in the detection of toxic substances in mine water samples. Methods This work informs the expression of lysosomal proteomic in yeast in response with toxic chemicals, such as sodium meta-arsenite and tetracycline, for screening specific biomarkers. After that, a recombinant yeast contained this biomarker were constructed for toxic detection in pure toxic chemicals and mine water samples. Results Each chemical had an optimal dose at which the fluorescent protein intensity reached the peak. In the case of water samples, the yeast showed the response with sample 1, 3, 4, and 5; whereas there is no response with sample 2, 6, and 7. Conclusions The recombinant yeast showed a high ability of toxic detection in response with several chemicals such as heavy metals and pharmaceuticals. In the case of mine water samples, the response varied depending on the sample content.

월쉬변환에 의한 가솔린엔진 실화검출에 관한 연구 (A Study on the Detection of Misfire in Gasoline Engine via Walsh Transform)

  • 이태표;김종부;안두수
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권6호
    • /
    • pp.299-306
    • /
    • 2000
  • The primary cause of air pollution by vehicles is imperfect combustion of fuel. One of the most usual causes of this imperfect combustion is the misfire in IC(Intenal Combustion) engine. Recently it is obligated for an ECU to monitor the emission level and warn the driver in case of exceeding specified emission standards. Therefore, in order to comply with this OBD-II regulations, car makers are investing a considerable amount into technology which would enable the detection of misfire and the particular cylinder in which misfire is taking place. So far, it has been able to detect misfire using engine speed, which can be obtained crank angle. However, such a method posed a problem in analyzing at high speed and in recognizing the misfire from the load impact at bumpy road. In this paper, misfire detection is made possible by simple arithmetic using WDFT, especially at high engine speed. In addition, the moving window method of a Walsh function is applied to determine the cylinders under misfire in case of multiple misfires. An actual experiment was conducted to prove that WDFT is applicable to effective in computation speed and to same result in misfire detection and cylinder determination at idle, part load and bumpy road conditions.

  • PDF

평균 배기 압력 구배 지수를 이용한 실화 검출 (The misfire detection using the mean exhaust pressure gradient index)

  • 정성원;심국상;김세웅
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.371-378
    • /
    • 2001
  • This paper proposes a method to detect the misfired cylinder using a new misfire detection index. The new method of misfired cylinder is a comparison of pressure gradient during the blowdown period of exhaust stroke. If a misfire occurs, the engine will he lost some power and consumes the more fuel and the torque will be unsteady. Most of all, the misfire affects a bad influence of the 3-way catalyst and emits unburned hydrocarbon in the air. To prevent these unusual phenomena and eliminate the factor of the environmental pollution, it is important to detect the misfired cylinder. To do the experiment, set up the assist device on the manifold. This assist device is not deformed for conventional exhaust manifold and installed in the end of the exhaust manifold. Experimental results showed that the method using the mean gradient pressure index is proven to be effective in the detection of misfired cylinder on gasoline engine regardless loads and revolutions of the engine.

  • PDF

UAV와 딥러닝을 활용한 야적퇴비 탐지 및 관리등급 산정 (Detection and Grading of Compost Heap Using UAV and Deep Learning)

  • 박미소;김흥민;김영민;박수호;김탁영;장선웅
    • 대한원격탐사학회지
    • /
    • 제40권1호
    • /
    • pp.33-43
    • /
    • 2024
  • 본 연구는 비점오염원 중 하나인 야적퇴비의 효율적인 탐지를 위해 You Only Look Once (YOLO)v8 모델과 DeepLabv3+ 모델의 적용 가능성을 평가하였다. 무인항공기(Unmanned Aerial Vehicle, UAV)를 이용하여 수집된 고해상도 영상을 바탕으로, 두 모델의 정량적 및 정성적 성능을 비교 분석하였다. 정량적 평가에서 YOLOv8 모델은 다양한 지표에서 우수한 성능을 나타내며, 특히 야적퇴비의 덮개 유무를 정확하게 식별할 수 있는 능력을 보였다. 이러한 결과는 YOLOv8 모델이 야적퇴비의 정밀한 탐지 및 분류에 효과적임을 시사하며, 이를 바탕으로 야적퇴비의 관리 등급을 산정하고 비점오염원 관리에 기여할 수 있는 새로운 접근 방법을 제공한다. 본 연구는 UAV와 딥러닝 기술을 활용한 야적퇴비 탐지 및 관리가 기존 현장 조사 방식의 한계를 극복하며 정확하고 효율적인 비점오염원 관리 전략 수립 및 수계환경 보호에 기여할 것으로 기대된다.

Detection of DNA Damage in Carp Using Single-Cell Gel Electrophoresis Assay for Genotoxicity Monitoring

  • Jin, Hai-Hong;Lee, Jae-Hyung;Hyun, Chang-Kee
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권2호
    • /
    • pp.268-275
    • /
    • 2004
  • To investigate the potential application of the single-cell gel electrophoresis (SCGE) assay to carp as an aquatic pollution monitoring technique, gill, liver, and blood cells were isolated from carp exposed to a direct-acting mutagen, N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), or indirect mutagen, $benzo[\alpha]pyrene$ $(B[\alpha]P)$, then the DNA strand breakage was analyzed using the assay. Based on testing 5 different cell isolation methods and 6 electrophoretic conditions, the optimized assay conditions were found to be cell isolation by filter pressing and electrophoresis at a lower voltage and longer running time (at 0.4 V/cm for 40 min). In preliminary experiments, gill and liver cells isolated from carp exposed to MNNG in vitro exhibited DNA damage signals even with 0.5 ppb exposure, which is a much higher dose than previously reported. In the gill cells isolated from carp exposed to 0.01-0.5 ppm MNNG in vivo, significant dose-and time-dependent increases were observed in the tail for 4 days. As such, the linear correlation between the relative damage index (RDI) values and time for each dose based on the initial 48-h exposure appeared to provide effective criteria for the genotoxicity monitoring of direct-acting mutagenic pollution. In contrast, the in vivo exposure of carp to 0.25-1.0 ppm of $B[\alpha]P$ for 7 days resulted in dose-and time-dependent responses in the liver cells, in which 24-h delayed responses for metabolizing activation and gradual repair after 48 h were also observed. Thus, the negative-sloped linear correlation between the RDI and time at each dose based on the initial 48 h appeared to provide more effective criteria for the genotoxicity monitoring of indirect mutagenic pollution.