• Title/Summary/Keyword: Pollution contribution rate

Search Result 38, Processing Time 0.021 seconds

Evaluation of the Contribution Ratio that the Pollution Loads of the Drainage Areas Affect Soyang-lake (배수구역의 유달오염부하량이 소양호 유역에 미치는 기여율 평가)

  • Park, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5363-5368
    • /
    • 2014
  • This study examined contribution rate on the Soyangho Lake watershed based on the flow regime, and seasonal change was evaluated by calculating the delivery pollution load of the drainage area of Soyangho Lake watershed. According to the contribution rate of the drainage area by the flow regime change, Inbukcheon Creek watershed's SS and T-P entry have recorded abnormal Six month flow and a contribution rate of 46% and 51% during the Low-water flow period. At the same time, the T-P recorded a 49.5% contribution rate and a contribution rate of 48.5% during the Low-water flow period. In sequence, Inbukcheon creek's SS entry recorded a comparatively higher contribution rate than the other drainage area, which are 39.6% and 44.3% during the entire season and 53.8% for T-P, as a result of observing the contribution rate based on the seasonal changes. The T-N at the Naerincheon Creek watershed for the entire season recorded a contribution rate between 39.6% and 44.3%. Overall, Inbukcheon Creek watershed's SS and T-P entry and Naerincheon creek's T-N had a high contribution rate on contaminant spill.

A Study on the Reduction of Total Phosphate of the Concerned Pollution Area in the Main Stream of Mangyeong River (만경강 본류 중 오염우심지역의 TP 저감방안 연구)

  • Jounghwa, Choi;Jaeog, Kwon;Miseon, Lee;Wook, Jang;Geunhwa, Choi;Eunhye, Ko;Seohyeon, Sim;Changwoo, Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.316-326
    • /
    • 2022
  • This study aimed to investigate the causes of the increasing Total Phosphate(TP) in the mainstream of Mangyeong river over the past 10 years, and suggested a reduction plan of about 3 points. First, the high TP concentration was continuously released in the discharge outlet of the Haepo bridge stormwater pipeline. The average TP concentration was 5.066 mg/L and values as high as 29.470 mg/L were measured. The highest pollution contribution rate to the Mangyeong river was more than 70 %. The cause of the pollution was expected to take place somewhere in Wanju Industrial Complex. Second, the average TP concentration of wastewater-treated effluent in the H factory was 0.405 mg/L. If a TP reduction facility is additionally installed in the H factory, it will help reduce TP uptake by Lake Saemangeum. Third, the TP concentration of untreated non-point source point flowing into the Samrae stream was very high with an average of 2.828 mg/L. Also, the pollution contribution rate of Samraecheon 2 to Mangyeong river was 21.8 % on average and up to 58 %. The pollution contribution rate was also high during the agricultural season and the winter, during which the flow rate is decreased. Investigation of these three points may be continuously needed, and analysis results and policy proposals presented to Jeollabukdo and Wanjugun to manage pollution sources.

Application of Margin of Safety Considering Regional Characteristics for the Management of Total Maximum Daily Loads (지역특성을 고려한 수질오염총량관리 안전부하량 적용)

  • Park, Jun Dae;Oh, Seung Young;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The allocation of margin of safety (MOS) at a uniform rate to all areas of the unit watershed makes it very difficult to keep the load allotment stable in the area for lack of reduction measures like forest land. This study developed an equation to calculate margin of safety differentially according to the regional characteristics. The equation was formulated on the basis of the regional characteristic factors such as a load contribution factor for land use type and a site conversion factor for the unit watershed. The load contribution factor represents a contribution of loads from a particular land use. The site conversion factor was derived from the site conversion ratio of a unit watershed. Margin of safety for the non-point pollution load in the land use sector decreased by 20~25% in three river basins. The margin of safety in the unit watersheds with low site occupation ratios decreased in high rate, while in the unit watersheds with large urban area decreased in low rate. With the application of the differential margin of safety considering regional characteristics, not only the reduction of pollution loads can become lighter but also it can be easier to develop plans for Total Maximum Daily Loads (TMDLs) even where the reduction measures are not available.

Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream (황구지천 유역의 오염부하 특성 및 지류 영향 평가)

  • Lim, Su-Jin;Lim, Byung-Ran;Lee, Han-Saem;Kang, Joo-Hyoung;Ahn, Tae-Ung;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.

Analysis of Characteristics of NPS Runoff and Pollution Contribution Rate in Songya-stream Watershed (송야천 유역의 비점오염물질 유출 특성 및 오염기여율 분석)

  • Kang Taeseong;Yu Nayeong;Shin Minhwan;Lim Kyoungjae;Park Minji;Park Baekyung;Kim Jonggun
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.316-328
    • /
    • 2023
  • In this study, the characteristics of nonpoint pollutant outflow and contribution rate of pollution in Songya-stream mainstream and tributaries were analyzed. Further, water pollution management and improvement measures for pollution-oriented rivers were proposed. An on-site investigation was conducted to determine the inflow of major pollutants into the basin, and it was found that pollutants generated from agricultural land and livestock facilities flowed into the river, resulting in a high concentration of turbid water. Based on the analysis results of the pollution load data calculated through actual measurement monitoring (flow and water quality) and the occurrence and emission load data calculated using the national pollution source survey data, the S3 and S6 were selected as the concerned pollution tributaries in the Songya-stream basin. Results of cluster analysis using Pearson correlation coefficient evaluation and Density based spatial clustering of applications with noise (DBSCAN) technique showed that the S3 and S6 were most consistent with the C2 cluster (a cluster of Songya-stream mainstream owned area) corresponding to the mainstream of Songya-stream. The analysis results of the major pollutants in the concerned pollution tributaries showed that livestock and land pollutants were the major pollutants. Consequently, optimal management techniques such as fertilizer management, water gate management in paddy, vegetated filter strip and livestock manure public treatment were proposed to reduce livestock and land pollutants.

The Estimation of the contribution rate of Mokpo Municipal Sewage Treatment Plant to the Improvement of Marine Water Quality in Mokpo Harbour (목포항 수질개선에 대한 목포하수처리장의 기여율 산정)

  • Kim Kwang-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.4
    • /
    • pp.37-44
    • /
    • 2003
  • In order to evaluate the contribution of MMSTP operation to the improvement of marine water quality of Mokpo harbour and to estimate the change of pollution loads flowing into Mokpo harbour after the operation of Mokpo Municipal Sewage Treatment Plant (MMSTP), the pollution loads flowing into Mokpo harbour from land in dry weather were surveyed and estimated on the bases of the seasonal flow rates and the seasonal water qualities of streams and effluents located around Mokpo harbour from summer, 1997 to spring, 1998 before the operation of MMSTP, and the pollution loads of the inflow and the effluent of MMSTP were also surveyed and estimated from winter, 1998 to spring, 1999 after the operation of MMSTP. The treatment rates of MMSTP were shown to be about 49% in COD, 76% in TSS, 79% in VSS, 3% in T-N, 7% in DIP, 29% In T-P and -32% in DIN. The change rates of pollution loads flowing into the inner harbour of Mokpo due to the operation of MMSTP were shown to be about 56% in COD, 78% in TSS, 84% in VSS, 45% in DIN, 22% in T-N, 34% in T-P and -14% in DIP The contribution rates of MMSTP operation to the reduction of total pollution loads flowing into the entire Mokpo harbour were found to be about 3% in COD, 3% in TSS, 5% in VSS, 1% in DIP, 3% in T-P and -1% in DIN.

  • PDF

Modeling for Pollution Contribution Rate of Land based Load in Masan Bay (마산만 육상기인오염원의 오염기여율 모델링)

  • Jung, Woo-Sung;Hong, Sok-Jin;Lee, Won-Chan;Kim, Hyung-Chul;Kim, Jin-ho;Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.59-66
    • /
    • 2016
  • Pollution contribution rate that is effect on water quality from land based load in Masan bay was showed quantifiably for coastal water quality management by using ecological model. It was calculated by difference of water quality concentration at each points t hat is calculated by each scenarios that are presence or absence of each sources (16 points). Results show that, rivers of Northern Masan bay contributed in Masan bay COD is 20 %, T-P is 62 % at northern part and COD is 10 %, T-P is 16 % at middle part. As a result, rivers of Northern Masan bay had effect on water quality of northern Masan bay and middle Masan bay. Also, T-P load affects water quality bigger than COD load, because T-P contribution rate bigger than COD contribution rate of northern rivers. Dukdong WTTP that is land pollution source of southern Masan bay contributed in Masan bay COD is 26 %, T-P is 11% at middle part, COD is 17 %, T-P is 7 % at middle part and COD is 10 %, T-P is 1 % at outer part. It affects water quality bigger at southern and middle of Masan bay than outer bay, because residual flow of bottom flows toward inner of Masan bay nearby Dukdong WTTP.

The Study on the Comparison of the ISCST3 Model and Receptor Model by Dispersion Tracing of Particulate Matter from Large Scale Pollution Sources (대단위배출원에서 기인한 입자상오염물질의 확산ㆍ추적을 통한 ISCST3모델과 수용모델의 비교연구)

  • 전상기;이성철;박경선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.789-803
    • /
    • 2003
  • The purpose of this study is to compare the usefulness between Gaussian dispersion model and receptor model with the experimental result of the dispersion tracing of the particulate pollutants from Taean coal-fired power plants. For this purpose, the component analysis of the collected PM 10 samples was performed. In order to trace the pollution sources, factor analysis was done with the result of the component analysis. As a result of the correlativity analysis of the fifteen power plants' profiles offered by US EPA, the correlativity of No.11202 source profile showed highest rate up to 84.5%. Thus it was adopted as proper one and the contribution rate by each pollution source was calculated by Chemical Mass Balance (CMB)-8 model. The contribution rate, which was the effect rate of the power plants on each measuring point, were calculated with a range of 24∼52% and the standard error was below 0.9 $\mu\textrm{g}$/㎥. This indicates the selection of the source profile was appropriate. Also, the concentrations of each point were calculated by the ISCST3 which is suggested by US EPA as one of the regulatory Gaussian dispersion model. The calculation result showed that the predicted concentration was 50∼58 $\mu\textrm{g}$/㎥, comparing with the measured result of 9∼65 $\mu\textrm{g}$/㎥. It was found that the concentration calculated by ISCST3 was underpredicted. It was thought that the receptor model was more favorable than the Gaussian dispersion model in estimating the effect of the particulate matter on a certain receptive point.

Economic Effects of the Management Model far Environment Pollution in Gwangyang Bay (광양만 환경오염 관리모델 연구의 경제적 파급효과 분석)

  • Nam Kwanghyun;Kwon Sukjae;Oh Weeyeong
    • Journal of Korea Technology Innovation Society
    • /
    • v.7 no.3
    • /
    • pp.657-679
    • /
    • 2004
  • The purpose of this paper is to measure economic impact of marine environment conservation research development project. Benefit-Cost(B/C) analysis and Contingent Valuation Methods(CVM) are used to valuate the benefits from the research development projects. A period of three years for research development fund is considered as a part of the costs and adjusted to the net present value (NPV) of the 2002 ending period. The environmental charges for marine environment improvement are considered for the benefit measurement. The benefits are estimated by using monthly average willingness to pay, which is 2,289 Korean won. The contribution of the developing a management model for environmental pollution in the Gwangyang Bay is evaluated utilizing survey data and information. Based on the assessment by expert groups, the contribution of the model was 37.5%. The research results showed that B/C ratio is 20.61, NPV is 89,200 million Korean won, and social rate of return is 185.7%. When the level of contribution is over 1.83% at the assessment of potential influence, it is recognized to be economically feasible. This research presents a quantitative framework for Research and Development projects for marine environment conservation, and it can be applied to decision making for the investment size of R&D projects.

  • PDF