• Title/Summary/Keyword: Pollutants

Search Result 4,214, Processing Time 0.031 seconds

A Case Study on Health Impact Assessment of Hazardous Air Pollutants in Industrial Complex Development Plan (산업단지 계획 시 유해대기오염물질에 대한 건강영향평가 사례 연구)

  • Kim, Sang-Mok;Son, Eun-Seong;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.616-625
    • /
    • 2019
  • Health impact assessment is implemented within the Environmental impact assessment for the purpose of minimizing health damage by predicting the impact on human health following implementation of the development project. In health impact assessment, manual revision is required due to the lack of consistency in the method of estimating hazardous air pollutants emissions. This study estimated the emissions by calculating the emissions of hazardous air pollutants based on the actual industrial complex development cases and completed health impact assessments. As a result of risk assessment based on exposure concentration using CALPUFF model, the risk assessment results were different for each of the emission estimation methods, and manual improvement on the emission estimation method is needed.

Comparison of water qualities and pollutants discharged to the East sea of Korea from Namdae and Yeongok stream in the Gangneung city (강릉 남대천과 연곡천의 수질과 동해 연안으로 방류되는 오염물질의 량 비교)

  • Yoon Yi Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.1
    • /
    • pp.68-77
    • /
    • 2003
  • The Water quality of Namdae and Yeongok stream, located in the Kangnung City, and pollutants discharged to the east sea of Korea were investigated during april to November 2002 in order to understand the costal pollution phenomena. The water qualify grade of Namdae stream vary between II and V of water standard. On the other hand, that of Yeongok Stream is keeping I or II. The temporal and spacial variation of Namdae stream are higher than Yeongok stream. The water pollutants discharged to the east sea of Korea from Yeongok stream are lower 15.5 times for BOD, 2.6 times for COD, 1.7 times for T-N, 6.9 times for T-P than from Namdae stream, of which water flux are 1.4 times higher and contain much more of pollutants than Yeongok stream. It may have some effect on the costal ecosystem according to their pollutant flux.

  • PDF

Simulation of Pollutants Transport using 2-D Advection-Dispersion Model near Intake Station (2차원 이송-확산모형을 이용한 취수장 인근에서의 오염물질의 혼합거동 모의)

  • Kim, Jae-Dong;Kim, Young-Do;Lyu, Si-Wan;Seo, Il-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.791-794
    • /
    • 2008
  • The transport and dispersion of pollutants in natural river is a principal issue in intake station management. To study the pollutant transport in natural rivers, the effect of meandering and confluence of tributary on mixing process have to analyzed. The objective of this study is to simulate the mixing and transport of pollutants for operating water gate of Nakdong Estuary Barrage around the intake station. Mulgeum intake station being used as drinking water sources for Pusan. The flow around the intake station is influenced by operating water gate of Nakdong Estuary Barrage which is located downstream. The water gate system includes ten individual gates. The minor gate is usually opened according to elevation of the sea. When the river flow increases, the main water gate is opened. Daepo stream, tributary of the Nakdong river, is on opposite side of the intake station. The pollutants from Daepo stream often flows into the intake station acoording to the flow pattern. In this study, based on this simulation results, proper water gate operation which can minimize negative impact will be provided.

  • PDF

Characteristics of Washed-off Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms (주차장 및 교량지역의 강우유출수내 비점오염물질의 특성 비교 및 동적 EMCs)

  • Kim, Lee-Hyung;Lee, Seonha
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.248-255
    • /
    • 2005
  • Since the water quality of drinking water sources has been recognized as a big issue, the ministry of Environment in Korea is designing the total maximum daily load (TMDL) program for 4 major large rivers. The TMDL program can be successfully performed as controling the nonpoint pollutants from watershed area near the river. Of the various landuses in nonpoint pollution, parking lots and bridges are stormwater intensive landuses because of high imperviousness and high pollutant mass emissions from vehicular activities. Vehicle emissions from those areas include different pollutants such as heavy metals, oil and grease and particulates from sources such as fuels, brake pad and tire wear, etc. Especially the pollutant washed-off from the landuses are directly affecting to the river water quality. Therefore this research was conducted to understand the magnitude and nature of the stormwater emissions with the goal of quantifying stormwater pollutant concentrations and mass emission rates of pollutants from parking lot and bridges in Korea. In Kongju city areas, two monitoring sites were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the useful data such as rainfall, water quality and runoff flow. This manuscripts will show the concentration changes during storm duration and EMCs to characterize the concentration profiles in different land uses. Also the first flush criteria will be suggested using dynamic EMCs. The definition of dynamic EMC is a new approach explaining the relationship of EMC and first flush effect.

Seasonals Pollutant Outflow Analysis in the Watershed of Soyang Lake by using Multivariate Analysis (다변량 분석을 이용한 소양호 유역의 계절별 오염물질 유출 해석)

  • Park, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3726-3734
    • /
    • 2012
  • This study evaluated the behavior of pollutants based on the seasonal change by selecting the branch river's factors that influence the outflow of pollutants in Soyang lake basin. The analysis method was the factor analysis that classified the factors of the drainage area influencing the outflow of pollutants, and evaluated selected representative factors. As a result of the study, SS and T-P factors should be classified as similar factors to the storm water runoff, and the improvement of water must be strived through managing source of pollution at the time of no rain. Second, as the result of the influence from the factors, spring and winter seasons usually exert 36% influence and summer and fall exert over 90% significant influence that the improvement of water through managing source of water seems possible. At last, the prediction about delivery pollution load considering the outflow characteristic of pollutants at the drainage area based on seasonal change by regarding selected factors as independent variables is possible.

Associations of Ambient Air Pollutant Concentrations With Respiratory Symptoms and Perceived Health Status in Japanese Adults With and Without Chronic Respiratory Diseases: A Panel Study

  • Nakao, Motoyuki;Yamauchi, Keiko;Mitsuma, Satoshi;Odaira, Tetsuro;Obata, Hideto;Chijimatsu, Yoichi;Ishihara, Yoko
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.6
    • /
    • pp.416-426
    • /
    • 2019
  • Objectives: In recent years, transboundary air pollution from mainland East Asia has led to growing concerns about air pollution in Japan. Air pollution is reportedly associated with the exacerbation of respiratory diseases. In this study, we assessed the effects of air pollution on respiratory symptoms and the health status of participants with and without chronic respiratory diseases. Methods: Participants (n=2753) with and without chronic respiratory diseases who visited healthcare facilities in Japan during February from 2010 to 2015 filled out a self-report questionnaire regarding their symptoms and perceived health status. Participants were followed up during April-May and June-July. Results: Oxidant concentrations were associated with respiratory symptoms, overall health, and quality of life (QoL). Suspended particulate matter (SPM) and particulate matter <$2.5{\mu}m$ levels were associated with physical fitness; SPM was also associated with QoL. Recent experience of an Asian sand dust event had a significant effect on allergic symptoms, change in health, and QoL. Conclusions: Respiratory symptoms were more strongly affected by oxidants than by other pollutants. Significant associations of air pollutants were found with a comprehensive range of items related to perceived health status, including overall health and QoL. Although the effects of air pollutants on respiratory symptoms and health status were more apparent among patients with respiratory diseases, the adverse effects of air pollutants were significant even among participants without such conditions.

Emission Characteristics of Air Pollutants and Black Carbon from Wood-pellet Stove and Boiler (목재 펠릿 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Kim, Daekeun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • This study was carried out simulating domestic utilization conditions of a wood pellet stove and a wood pellet boiler in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the pellet stove were: for TSP 4.58 g/kg, for $PM_{10}$ 3.35 g/kg, for $PM_{2.5}$ 2.48 g/kg, CO 119.23 g/kg, NO 14.40 g/kg, $SO_2$ 0.17 g/kg, TVOC 37.73 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the pellet boiler appliance: for TSP 4.73 g/kg, for $PM_{10}$ 3.41 g/kg, for $PM_{2.5}$ 2.63 g/kg, CO 161.51 g/kg, NO 13.67 g/kg, $SO_2$ 0.19 g/kg, TVOC 45.22 g/kg, $NH_3$ 0.02 g/kg.

Emission Characteristics of Air Pollutants and Black Carbon from Wood Stove and Boiler (화목 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Manually fed firewood burning appliances, i.e., stove and boiler, were tested in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the wood stove were: for TSP 15.45 g/kg, for $PM_{10}$ 6.53 g/kg, $PM_{2.5}$ 4.16 g/kg, CO 175.49 g/kg, NO 1.58 g/kg, $SO_2$ 0.15 g/kg, TVOC 48.02 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the wood boiler appliance: for TSP 12.23 g/kg, for $PM_{10}$ 5.84 g/kg, $PM_{2.5}$ 3.66 g/kg, CO 146.74 g/kg, NO 1.42 g/kg, $SO_2$ 0.15 g/kg, TVOC 47.78 g/kg, $NH_3$ 0.01 g/kg.

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

Emission of Airbone Pollutants from Traditional Korean Fireplace (아궁이 사용에 의한 대기오염물질의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee
    • Journal of Climate Change Research
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • Emission from the traditional Korean fireplace, or the under-floor heating and cooking device, can contribute significantly to airborne pollutants inventories. This study has systematically measured emissions of airborne pollutants from the fireplace when used different fuels such as firewood, agricultural crop residuals, household wastes. The results show that emission factors of airborne pollutants through the primary combustion of firewood were 3.22 g/kg for TSP, 2.93 g/kg for $PM_{10}$, 2.65 g/kg for $PM_{2.5}$, 174.19 g/kg for CO, 7.77 g/kg for NO, 0.15 g/kg for $SO_2$, 40.53 g/kg for TVOC and 0.03 g/kg for $NH_3$; from burning of agricultural crop residues, 2.85 g/kg for TSP, 1.38 g/kg for $PM_{10}$, 1.14 g/kg for $PM_{2.5}$, 126.47 g/kg for CO, 12.60 g/kg for NO, 0.20 g/kg for $SO_2$, 33.73 g/kg for TVOC and 0.02 g/kg for $NH_3$; and for household wastes, 10.52 g/kg for TSP, 8.52 g/kg for $PM_{10}$, 6.23 g/kg for $PM_{2.5}$, 72.86 g/kg for CO, 11.73 g/kg for NO, 0.20 g/kg for $SO_2$, 47.10 g/kg for TVOC and 0.20 g/kg for $NH_3$.