• Title/Summary/Keyword: Pollutants

Search Result 4,214, Processing Time 0.029 seconds

Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System (개선된 여과형 시설의 비점오염물질 처리효율 평가)

  • Kang, Hee-Man;Choi, Ji-Yon;Kim, Lee-Hyung;Bae, Woo-Keun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • The objective of this study was to evaluate the efficiency of a modified filtration system treating non-point source (NPS) pollutants. The developed Best Management Practice (BMP) technology was designed based on the geographical and climatic characteristics of the site. A lab-scale test experiment was conducted using three different hydraulic loading rates representing the first flush flow, average flow and overflow conditions during a rainfall event. Water quality analysis was performed on the water samples taken at the inflow, outflow and infiltration during the test experiment of the lab-scale BMP. Also, the water and mass balance at different hydraulic loading rates was determined. Results from the lab-scale test experiment showed that the lab-scale BMP had a high removal efficiency of 80-90% for all NPS pollutants. The overflow test condition obtained the lowest removal efficiency among the hydraulic loading rates because it gave less opportunity for the pollutants to be filtered and retained inside system. The infiltration ratio was approximately 1 % of the inflow and outflow. Increasing the infiltration ratio requires technical approach of soil amendment where the BMP is installed.

The Comparison Study in the Extraction of Inorganic Priority Pollutants from Solid Wastes (고체 폐기물 시료 중의 무기 Priority Pollutants 추출법 비교 연구)

  • Ahn, Tae-Ho;Lee, Huk-Hee;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.395-402
    • /
    • 1997
  • The comparison study between EPA method 3050 and the test method offered by Ministry of Environment in Korea was performed to investigate a matrix effect on extraction. In this study, 12 inorganic priority pollutants(Cd, Cr, Cu, Pb, Ni, Zn, As, Sb, Se, Hg, Be, Tl) were spiked to the sludges and estuary sediment samples. The extracts were analyzed by AAS, HG-AAS, and ICP/MS. Results were discussed in terms of recoveries, relative standard deviations, and the method detection limits. Mean recovery of the elements except As, Sb, and Se was 93% when the procedure of EPA method was applied. The Korean extraction method, however. showed a significant matrix effect to give very poor recoveries.

  • PDF

Formation of Salty Materials on Granite Surface by Environmental Pollutants - Effects of TiO2 - (환경오염물질에 의한 화강암 표면에서의 염의 생성에 관한 연구 - TiO2의 영향을 중심으로 -)

  • Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1754-1759
    • /
    • 2010
  • Because the stone cultural properties located outdoors, they have been altered and deteriorated in external appearance due to environmental factors such as acid rain, extreme change in temperature, and salts. Damage to stone cultural properties is accelerated particularly due to recent industrial development and environmental pollution. An experimental study was conducted to evaluate the effect of environmental contaminants(sea water and air pollutants such as, $SO_2$, NO, $CO_2$) on the weathering of granite. And as part of the developing of conservation method, $TiO_2$ catalyst was prepared and tested. After expose a granite to sea water and air pollutants, the mineral compositions of the tested granite surface were lower then that of the fresh granite. And absorption capacity of the weathered granite was steadily increased. From these results, it was expected that granite could be weathered by sea water and air pollutants. For the $TiO_2$ coated granite, absorption capacity was slightly enhanced compared to the $TiO_2$ non-coated granite. Therefore, the $TiO_2$ coating method tested in this study considered to be a viable method to assist in the conservation of granite from environmental contaminants.

A Study on the Management of Harzardous Chemlcals from the Middle School Science Class (중학교 과학실에서 사용되는 유해 화학물질의 관리방안에 관한 조사 연구)

  • Kim, Sang-ok;Chung, Yong
    • Hwankyungkyoyuk
    • /
    • v.2 no.1
    • /
    • pp.69-83
    • /
    • 1991
  • The management and disposal of harzardous chemicals from the middle school science class was studied for the safety of student and for the protection of the environment. This study was undertaken by analysis of 5 kinks of current middle school science text book and questionnaire survey, and reviewed on the recommended methods for the disposal of harzardous chemical wastes from science class. There are 237 chemicals determined in the middle school science text books and 87 among them actually used in middle school science laboratory. 51 chemicals are classified as harzardous ones and 49 highly hazardous according to the 'Law of Toxic Chemicals management'. 116 chemicals are defined as water pollutants and 10 are highly hazardous water pollutants according to the 'Water Quality Control Law' as well are 91 chemicals as air pollutants and 19 are highly hazardous air pollutants according to the 'Air Quality Control Law' Questionnaire survey results the identification of toxic chemicals, need for education, awareness of toxic effects and current problems in the management. Disposal of toxic chemicals in middle school science class has been undertaken without any treatment, which could be caused of environmental pollution. Most of science teacher wanted to have opportunities to attend supplement courses for the management and disposal of chemicals for the safety and environmental protection. Simple and applicable methods for the management and disposal of chemicals at middle school science level should be strongly recommended to be installed.

  • PDF

Sampling and Analysis of Acidic Air Pollutants Using an Annular Denuder System during the Summer Season in Chongju City (디누더 측정기를 이용한 여름철 청주시의 산성오염물질 측정과 분석)

  • 이학성;강병욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.441-448
    • /
    • 1996
  • The cyclone/annular denuder system/filter pack sampling system (ADS) was used to collect the acidic air pollutants in Chongju city. The data set was collected on nine different days with 24 hour sampling period from July 27 through August 27, 1995. The chemical species measured were $HNO_3, HNO_2, SO_2 and NH_3$ in the gas phase, and $PM_{2.5}(d_P<2.5 \mum), SO_4^{2-}, NO_3^- and NH_4^+$ in the particulate phase. Mean concentrations measured from this study were: $0.90 \mug/m^3 for HNO_3, 1.27 \mug/m^3 for HNO_2, 10.9 \mug/m^3 for SO_2, 4.82 \mug/m^3 for NH_3, 27.5 \mug/m^3 for PM_{2.5}, 5.24 \mug/m^3 for SO_4^{2-}, 1.22 \mug/m^3 for NO_3^-, and 1.64 \mug/m^3 for NH_4^+$. The fine particle $(PM_{2.5})$ mass measured for the ADS samples was slightly higher than the fine particle mass measured for the corresponding dichotomous sampler. For the wind coming from Chongju industrial complex the concentrations of acidic air pollutants measured were higher when compared with other directions. Specially, $SO_2 and PM_{2.5}$ concentrations for the wind coming from Chongju industrial complex were 3.6 and about 2 times, respectively, higher than those of other wind directions. High correlations were observed between $PM_{2.5} and fine particle's ion components $(r=0.82 with SO_4^{2-}, r=0.76 with NO_3^- and r=0.89 with NH_4^+). NH_4^+ and SO_4^{2-}$ was also highly correlated (r=0.97).

  • PDF

A Study on the Improvement of Indoor Air Quality in Apartment Buildings (공동주택의 실내공기환경 개선에 관한 연구)

  • Lee, S.H.;Park, J.C.;Rhee, E.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.397-412
    • /
    • 1996
  • This study aims to present the fundamental strategies to improve the Indoor Air Quality (IAQ) in apartment buildings. To investigate the concentration of indoor air pollutants such as radon, formaldehyde, and VOCs, both the document survey and the field measurement were conducted. In addition, to identify the source of the air pollutants, the laboratory experiment was carried out for various building materials. Finally, the minimum period to be reserved befor3e building occupation to ensure healthy IAQ, which largely depends on the ventilation rates, was simulated using a simple compuer program. The results of this study can be summarized as follows: 1. In case of newly-constructed apartment houses, concentrations of formaldehyde, VOCs and radon were found to exceed the standard. Meanwhile, at existing apartment houses, concentrations of VOCs, particularly toluene and xylene, highly exceeded the standasrd level. Concentrations of formaldehyde and radon, however, had been lowered according to the duration of occupation. 2. The laboratory experiment of concentration of pollutants per square meter of building material surface area showed that radon gas was much emitted from the gypsumboard; formaldehyde from flooring and wallpaper; and VOCs from paints and kitchen furnishings. The emission rates of formaldehyde and VOCs were proportional to air temperature. 3. According to the simulation of the minimum period to be reserved before occupation, newly-constructed airtight houses required about 190-200 days, and naturally ventialted houses with fully-open-windows required about 20-45days, in order to keep the level of radon gas lower than standard. Therefore, with the current practice, the date of occupation should be delayed for about 15 days.

  • PDF

Pollutants Discharge Modeling in Mankyung and Dongjin Rivers (만경강.동진강 유역의 오염물질 유출모델링)

  • 고재원;조홍연;정신택;권혁민
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.2
    • /
    • pp.108-115
    • /
    • 2002
  • Pollutants discharge modeling was carried out in the watershed of Mankyung and Dongjin rivers. The watershed and pollutants source information extracted and analysed by the GIS tool was used as the model input parameters. This model was calibrated by comparison of the measured and computed monthly freshwater discharge and water quality(WQ) concentration. The compared WQ data are the ten-year-mean WQ concentration and monthly WQ concentration in 1999. The results show that the watershed runoff is underestimated in summer season, although the seasonal trends are relatively well estimated. The WQ concentrations were also relatively well estimated except Iksancheon. The computed concentration was much lower than the observed concentration in Iksancheon because of the effect of polluted sediment. Thus, the effects of polluted sediment on water column need further study through measuring and analysing the degree of the sediment contamination.

Characteristics of HFIX Insulated Wire Sheaths Contaminated by Pollutants (오염물질에 따른 HFIX 절연전선 피복의 특성 변화에 관한 연구)

  • Choi, Su-Gil;Nam, Yeong-Jae;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.8-17
    • /
    • 2020
  • In this study, the characteristics of HFIX insulated wire sheaths contaminated by pollutants were examined. KS C IEC 60811-1-3 standard was followed in performing the water-resistance wire tests. Pollutants were selected, and the specimens were exposed to the pollutants for a maximum duration of four weeks. The maximum tensile load and the elongation rate were measured each week. As the period of pollution exposure increased, the maximum tensile load of the specimens decreased by 6.22% and 6.52% at room temperature and high temperature, respectively, and 19.94% for specimens coated with a rust-proof lubricant. The elongation rate also decreased rapidly, such that the reductions in the properties of the sheath were significant. From the analysis of the surfaces using a scanning microscope, as the contamination period increased, structural changes such as perforation, split, and melting occurred, and the mechanical properties of the specimens decreased. Therefore, it is necessary to develop and follow an inspection cycle and periodically carry out repairs to prevent the deterioration of insulated wires.

A Study on the Annual Increase of Air Pollutant Emissions in Korea (대기오염물질(大氣汚染物質) 배출량(排出量)의 연도별추세(年度別趨勢)에 관(關)한 연구(硏究))

  • Cho, Moon-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 1976
  • In order to provide bases for the control of air pollutants in Korea, the author figured out the trend on the annual increase of air pollutants emitted in the process of combustions, and estimated the amounts of air pollutants of the future years from 1975 to 1981. 1) In 1973 the consumption rate of coal was 1.2 times of that of fuel oil. The consumption rate of them would be same in 1975 and 1977. However, the rate of fuel oil would exceed that of coal in 1979. Incontrast with the rate in 1979. The one of coal would be increased faster and faster to show reverse trend of consumption in 1981. 2) The estimated amounts of air pollutant emissions in the years of 1973, 1975, 1977, 1979 ana 1981 were 1,561,800, 1,921,700, 2,253,300, 2,769,000, and 3,145,700 tons respectively. These indicated that the amount of air pollutants in 1981 would be about 2 times of that in 1973. 3) The amounts of sulfur oxides emissions in 1981 would be 2.3 times of that in 1973, nitrogen oxides 2.2 times, carbon monoxide 1.7 times, particulate 2.0 times and hydrocarbon 2.0 times. 4) The estimated amounts of air pollutant emissions per unit area($km^2$) in the years of 1965, 1971, 1975 and 1980 were 5.2, 14.5, 19.5 and 28.7 tons respectively. These indicated that the amount of air pollutant emissions per unit area would increase 5.5 times in 1980 comparing the one in 1965.

  • PDF

Removal of Pollutants using Amphiphilic Polymer Nanoparticles in Micellar-Enhanced Utrafiltration (한외여과공정에서 양쪽성 고분자 나노파티클을 이용한 오염물 제거)

  • Shim Jin-Kie;Noh Sang-Il;Lee Sang-Bong;Cho Kye-Min;Lee Young-Moo
    • Membrane Journal
    • /
    • v.16 no.1
    • /
    • pp.59-67
    • /
    • 2006
  • Biodegradable amphiphilic polymer was synthesized for removing hydrophobic pollutants(phenol, 4-nitrophenol, benzene, and toluene) and metal ions ($Cs^{+},\;Mg^{2+},\;Cu^{2+},\;Ni^{2+}$, and $Cr^{3}$). The methoxy poly(ethylene glycol)s with different molecular weights (1,100 and 5,000) were used as a hydrophilic segment. The rejection ratio improved in the relatively high molecular weight of MPEG. The rejection ratio of biodegradable nanoparticles without pollutants was over 98%. In removal of hydrophobic pollutants, the rejection ratio increased with the hydrophobic properties. The electron valence affects the rejection ratio of metal ions, indicating rejection ratio was ordered as $3^{+}>2^{+}>1^{+}$.