• Title/Summary/Keyword: Pollutant removal efficiency

Search Result 208, Processing Time 0.025 seconds

A comparative study for adsorption of carbolic acid by synthetic resins

  • Uslu, Hasan;Bamufleh, Hisham S.
    • Membrane and Water Treatment
    • /
    • v.6 no.6
    • /
    • pp.439-449
    • /
    • 2015
  • Carbolic Acid which is called phenol is one of the important starting and/or intermediate materials in various industrial processes. However, its excessive release into environment poses a threat to living organisms, as it is a highly carcinogens and hazardous pollutant even at the very low concentration. Thus removal of phenol from polluted environments is very crucial for sustainable remediation process. We developed a low cost adsorption method for separating phenol from a model aqueous solution. The phenol adsorption was studied using two adsorbents i.e., Amber lite XAD-16 and Amber lite XAD-7 HP with a constant amount of resin 0.1 g at varying aqueous phenol concentrations ($50-200mgL^{-1}$) at room temperature. We compared the efficacy of two phenol adsorbents for removing higher phenol concentrations from the media. We investigated equilibrium and kinetics studies of phenol adsorption employing Freundlich, Temkin and Langmuir isotherms. Amberlite XAD-16 performed better than Amberlite XAD-7 HP in terms of phenol removal efficiency that amounted to 95.52%. Pseudo second order model was highly fitted for both of the adsorption systems. The coefficient of determination ($R^2$) with Langmuir isotherm was found to be 0.98 for Amberlite XAD-7 HP. However, Freundlich isotherm showed $R^2$ value of 0.95 for Amberlite XAD-16, indicating that both isotherms could be described for the isotherms on XAD-7 HP and Amberlite XAD-16, respectively.

An overview of functionalised carbon nanomaterial for organic pollutant removal

  • Jun, Lau Yien;Mubarak, N.M.;Yee, Min Juey;Yon, Lau Sie;Bing, Chua Han;Khalid, Mohammad;Abdullah, E.C.
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.175-186
    • /
    • 2018
  • Carbon nanomaterials (CNMs), particularly carbon nanotube and graphene-based materials, are rapidly emerging as one of the most effective adsorbents for wastewater treatment. CNMs hold great potential as new generation adsorbents due to their high surface to volume ratio, as well as extraordinary chemical, mechanical and thermal stabilities. However, implementation of pristine CNMs in real world applications are still hindered due to their poor solubility in most solvents. Hence, surface modification of CNMs is essential for wastewater treatment application in order to improve its solubility, chemical stability, fouling resistance and efficiency. Numerous studies have reported the applications of functionalized CNMs as very promising adsorbents for treating organic and inorganic wastewater pollutants. In this paper, the removal of organic dye and phenol contaminants from wastewater using various type of functionalized CNMs are highlighted and summarized. Challenges and future opportunities for application of these CNMs as adsorbents in sustainable wastewater treatment are also addressed in this paper.

A Study on Low Emission Pulverized Coal Combustion in the 2 Staged Coaxial Cyclone Combustor (2단 동축형 Cyclone 연소기를 이용한 저공해 미분탄 연소특성 연구)

  • Choi, Sang-Il;Park, Chu-Sik;Kim, Sung-One;Kim, Ho-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.67-83
    • /
    • 1999
  • The objective of this study is development of low emission pulverized coal combustor for reducing pollutant emission generated from coal combustion. Low emission combustion technology for reducing NOx and fly ash was investigated by using 2 stage coaxial cyclone combustor. Staged combustion was employed for NOx reduction and high temperature slagging combustion was also studied for fly ash removal in the combustor. The result of this study shows that the low emission combustion system can reduce the amount of atmospheric pollutions with improved boiler efficiency and performance.

  • PDF

Toluene Monooxygenase의 Peroxide shuntting에 의한 TCE와 PCE 분해 특성

  • 류두현;김형수;최용욱;김용미;이경애;유재수;조현
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.277-280
    • /
    • 2004
  • TCE and PCE, suspected carcinogens, are the most common groundwater pollutant from extensive use as a solvent and degreaser. Escherichia coli TGI pBSKAN TOM Green and E. coli TGI pBSKAN ToMO, which were used DNA shuffling technique, produce Toluene-o-monooxygenase(TOM) and toluene-o-xylene- monooxygenase(ToMO). These cells and enzymes are degrading TCE and PCE, TOM and ToMO are needed to cofactor, such as NADH, NADPH and other cofactors. Used TCE and PCE degrading microorganisms experiment the contaminated material removal efficiency. A shunting test used NAD and Hydrogen peroxide.

  • PDF

Characteristics of water quality at Han stream retention ponds in Jeju City (제주시 한천 저류지의 수질 특성)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.207-214
    • /
    • 2013
  • To evaluate characteristics of water quality in Jeju, a study was implemented for Han stream and retention ponds. Inflow water quality of retention ponds was heavily dependent on precedent rainfall, and no pesticide was detected due to the little artificial pollution sources. A smooth settling efficiency curve was noticed because heavy particles were already settled down in front of the retention pond. There were weak relationships between retention time and water quality, and this can be attributable to high concentration of pollutants influx at peak inflow. In addition, as Han stream retention pond has a role of groundwater recharge, inflow control based on water quality as well as quantity is needed to maximize pollutant removal at the retention ponds.

Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control (우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과)

  • Lim, Bong-Su;Park, Youn-Hae;Kim, Tae-Eung
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.

A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant (비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구)

  • Youn, Jae-Seo;Kim, Sang-Min;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.506-512
    • /
    • 2018
  • The fine dust generated in the home and restaurant business occupies a low ratio of about 4% of the total fine dust emissions. However, at the foodservice business, the rate of change of the pollutant concentration is very high, so that the temporary fine dust concentration can be measured up to 60 times. The pollutants generated from non-industrial combustion plants consist of particulate fine dust and gaseous organic compounds. To remove these pollutants, cleaning dust collection system, which is an effective system for simultaneous removal of gaseous and particulate matter, is applied. This is a method of increasing the probability of diffusion capture of the Brownian motion by pressurized liquid injection method using the atomizing nozzle. The dust removal efficiency of the fine dust collecting system was analyzed by nozzle spraying air pressure condition and angle using the manufactured fine dust removing system. As a result, it was confirmed that the efficiency of removal of fine dust and gaseous organic compounds was more than 90%. The developed system is expected to be highly usable in the future because it can remove particulate dust from the existing plant hood system without any installation cost.

Biofilm Processes for Volume Decrease in Recirculating Water Treatment Systems for Aquaculture

  • Kim Jeong-Sook;Yoon Gil-Ha;Ghim See-Jun;Kang Lim-Seok;Lee Byung-Hun
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.2
    • /
    • pp.242-249
    • /
    • 1998
  • The engineering aspect of water treatment processes in the recirculating aquaculture system was studied. To recycle the water in the aquaculture system, a wastewater treatment process was required to maintain high water quality for the growth and health of the cultured fish. In this study, three different biofilm processes were used to reduce the concentration of organic matters and ammonia from the recirculating water - two phase fluidized bed, three phase fluidized bed, and trickling filter. The objectives of this research were to evaluate the optimum treatment conditions of the biofilm processes for the recirculating aquaculture system, and thereby reduce the volume of biofilm processes, which are commonly used for the recycle water treatment processes for aquaculture. The result of this study showed that the removal efficiency of organic matters by trickling filter was found to be lower than that of the fluidized bed. In the trickling filter system, anthracite showed better organic removal efficiency than crushed stone as a media. In the two phase fluidized bed, the maximum removal efficiency of either organics or ammonia was obtained when both the packing rate of media was maintained to $40\%$ of total reactor depth excepting sediment zone and the bed expansion rate was maintained to $100\%$. When 100 tilapia (Oreochromis niloticus) of each average 200g was reared, the pollutant production rate was 0.07g $NH_4\;^+-N/kg$ fish/day and 0.06g P04-3-P/kg fish/day, and sludge production rate was 0.39 g SS/kg fish/day. In the two phase and three phase fluidized bed, the volume of water treatment tank could be calculated from an empirical equation by using the relationship between the influent COD to $NH_4\;^+-N$ ratio (C/N, -), media concentration (Cm, g/L), influent ammonia nitrogen concentration (Ni, mg/L), effluent ammonia nitrogen concentration (Ne, mg/L), bed expansion rate $(E,\;\%)$, and influent flowrate $(Q,\;m^3/hr)$. The empirical equation from this study is $$V_2\;=\;10^{3.1279}\;C/N^{3.5461}\;C_m\;^{-3.7473}\;N_i\;^{4.6477}\;E^{0.0326}\;N_e\;^{-0..8849}\;Q\;(Two\;Phase\;FB) V_3\;=\;10^{11.7507}\;C/N^{-1.2330}\;C_m\;^{-6.5715}\;N_i\;^{1.5091}\;N_e\;^{-1.8489}\;Q (Three\;Phase\;FB)$$

  • PDF

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.