Gas Removal Characteristics of Air Clean System Applying a Magnetic Field (자계가 인가된 공기청정장치의 가스 제거 특성)

  • Shin, Soo-Youn;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.921-925
    • /
    • 2007
  • Gas removal characteristics of an air clean system, consisted of a filter and a nonthermal discharge plasma reactor with a magnetic field, have been investigated with emphasis on the enhancing gas removal efficiency of the applied magnetic field. It is found that the magnetic field influenced significantly to the corona discharge characteristics, decreasing the corona onset voltage and increasing the corona current. As a result, the proposed air clean system with the magnetic field showed the higher removal efficiency of the gas (e.g., trimethlyamine) than that of without the magnetic field. This would be because the magnetic field applied to the discharge plasma reactor of the air clean system can elevate the corona characteristics, and activate the generation of ozone, thus the removal efficiency of the gas was concurrently enhanced. This reveals that the proposed air clean system with the magnetic field could be used as an effective means of removal an indoor pollutant gas.

Effect of Contaminant Source Location on Indoor Air Quality

  • Lee, Hee-Kwan;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.1-7
    • /
    • 1998
  • This paper presents an experimental study for understanding the indoor air quality in a room. A model room, which had a ceiling-mounted supply and a sidewall-mounted exhaust, was used to examine the effect of air exchange rate (AER) and contaminant source location (CSL) as a function of the elapsed time. A tracer gas method, using carbon monoxide tracer, gas analyzers, and a data acquisition system, was applied to study the ventilation air distribution and the tracer removal efficiency, so-called pollutant removal efficiency, in the model room. The experiment was composed of two parts; firstly the AER was varied to examine its effect on the ventilation air distribution and the ventilation effectiveness and secondly both AER and CSL were considered to determine their effect on the pollutant removal efficiency. It was found that the ventilation effectiveness in the model was proportional to AER but not linearly. It was also found that changing the CSL can improve the pollutant removal efficiency. In some cases, the efficiency improvement by increasing AER was achieved by simply changing CSL.

  • PDF

Estimation of the Pollutant Removal Efficiency in a Buffer Strip Using a SWAT Model

  • Lee, Eun-Jeong;Choi, Kyoung-Sik;Kim, Tae-Geun
    • Environmental Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.61-67
    • /
    • 2011
  • The water quality from nonpoint source run off results from different land use types has been studied. The construction of a buffer strip is one method of nonpoint source pollutant control. The Soil and Water Assessment Tool (SWAT) model has been applied to estimate the pollutant removal through the buffer strip. When the non-business land has been changed into grass to form a buffer-strip, the change of land use effects the results of the model according to measures of the water quality. The data from a water level station within the watershed in the years 2006 and 2007 was used for calibration and validation of the model. Under the rainfall conditions in 2007, the removal rates of SS, BOD, TN, TP were 11.5%, 9.5%, 1.2%, and 4.5%, respectively. During the rainy days, the removal rates at the buffer strip were 92.3% of SS, 91.2% of BOD, 82.4% of TN, and 83.5% of TP. The pollutants from nonpoint sources were effectively removed by over 80% as they passed through the buffer strips. Rainfall resulted in soil erosion, which led to an increase in the SS concentration, therefore, the construction of buffer strips protected the streams from SS inflows. Since TN concentrations are affected by the inflows of ground water and the N concentration of the rainfall, the removal rate of TN was relatively lower than for the other pollutants.

The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model (실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

Evaluation of urban pollutant washoff characteristics and treatment efficiency of a small constructed wetland

  • Reyes, Nash Jett DG.;Geronimo, Franz Kevin F.;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.412-412
    • /
    • 2019
  • Nature-based solutions (NBS) offer a wide variety of techniques that promote cost-efficient stormwater management practices. In particular, low impact development facilities utilize NBS principles to restore the ecosystem services in a highly-urbanized area. Despite the advancements in these technologies, several considerations should still be addressed to ensure optimum functionality and attainment of desired pollutant removal efficiency a LID facility. This study evaluated the mass flushing characteristics of pollutants in an urban catchment and the efficiency of a small constructed wetland (SCW) in treating urban stormwater runoff. 21 rainfall events from 2010 to 2018 were monitored to determine and quantify stormwater pollutants. The highest pollutant washoff was observed on rainfall depths ranging from 0.1mm to 10mm, whereas events with greater rainfall depths exhibited lower pollutant concentrations due to dilution effect. However, the SCW manifested lower pollutant-removal performance on rainfall depths exceeding 10mm due to the exceedance of the facility's design rainfall. This study is beneficial in assessing the dynamics of pollutant washoff and efficiency of LID facilities subjected under various external factors.

  • PDF

Distribution and Nutrient Removal Capacity of Aquatic Plants in Relation to Pollutant Load from the Watershed of Youngsan River (영산강 유역으로부터 유입되는 오염부하량에 따른 수생식물의 분포, 질산환원효소 활성 및 그 정화능)

  • Ihm, Byung-Sun;Ha-song Kim;Jeom-Sook Lee;KyeHong Suh
    • The Korean Journal of Ecology
    • /
    • v.19 no.5
    • /
    • pp.487-496
    • /
    • 1996
  • This study was conducted to investigate pollutant loading, were quality and plant distribution of 8 streams which are tributaries of the Youngsan River. The nitrate reductase activity (NRA) and nutrient removall capacity of the most frequently occurring aquatic plants on streamside were also determined. As a result, the pollutant loading appeared to be correlated with the area of watershed, while the water quality was related to the land use pattern of each steam. The aquatic plants were distributed differently among the streams; Hydrilla verticillata - Potamogeton crispus, Numphoides peltata - Hydrocharis dubia and Polygonum thunbergii - Phragmites japonica were dominant at the Orye Chon, Jungan Chon, Whangryong River and Jiseok Chon, while potamogeton crispus - Lemma paucicostata, Zizania latifolia - Phragmites communis were dominant at the Youngam Chon and Munpyeong Chon. Persicaria hydropiper and Echinochloa crus-galli var. oryzicola were dominant at Kwangju Chon which was polluted with domestic wastewater. >From the measurement of leaf NRA for dominant species, the highest value of NRA was shown by the Polygonum thunbergii, followed by Oenanthe javanica > Phragmites communis > Zizania latifolia > Lemma paucicostata. The highest nitrogen and phosphorus removal capacity was found in Phragmites communis.

  • PDF

Analysis of Effects of Space Charge in Removal efficiency of Pollutant using Dielectric Barrier Discharges (유전체장벽방전효과를 이용한 공해물질 제거 효율에 미치는 공간전하의 영향 분석)

  • Nam, S.H.;Jeon, S.I.;Lee, D.Y.;Lee, J.H.;Han, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1441-1443
    • /
    • 1998
  • In this work, the effects of space charge was analyzed in removal efficiency of pollutant using dielectric barrier discharges. In order to investigate effects of space charge, two dielectrics(XLPE and TR-XLPE) was chosen which are different in space charge distribution. The simultaneously measurement of space charge and discharge current was carried out in XLPE and TR-XLPE with air gap by Pulsed-Electro-Acoustic Method in ac. Also, the removal efficiency is measured by classical ozone generator(von Siemens 1875). From the experimental results, we knew that the space charge distribution affects the discharge patterns. The more space charge is in surface, the quickly discharge initiates and the magnitude of discharge is increased when polarity changes. And these affect the removal efficiency of pollutant.

  • PDF

Effect of Road Sweeping on the Abatement of Runoff Pollution Loads from in the Highway (고속도로 노면 청소에 따른 강우시 유출오염부하 저감 효과 분석)

  • Kang, Heeman;Lee, Doojin;Yoon, Hunsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.851-860
    • /
    • 2012
  • In this study, to evaluate the abatement of runoff pollution loads by the road sweeping(cleaning), various investigations are implemented at the sample area of the highway. As the results of evaluating the removal efficiency of pollutants along road cleaning, TSS showed about 78 % of the removal efficiency and COD showed 49 % of removal efficiency through the operation of cleaning vehicle of vacuum suction method. In case of TN and TP, they showed the relatively-lower removal efficiency by 30~35 %. TSS removal efficiency along the number of cleaning appeared about 60 % in case of one time of cleaning and the additional removal effect did not appear though the number of cleaning increased to two times. With running speed of cleaning vehicle, TSS removal ratio is lessened from 60 % to 20 % when cleaning vehicle speed up to 20 km/hr from 6 km/hr. It seems that the reasons why the removal efficiencies are inversely proportional to its speed are related to the lower vacuum efficiencies and the disturbed particles on the road. In the pollutant build-up analysis, it is showed that it takes more time to the critical pollutant build-up in the shoulder than the center of the road. It is also showed that the proper cleaning cycle is recommended as 4~6 dry weather days without rainfall events.

Estimation of Nonpoint Pollutant Removal Capacity in the Buffer Strip with AnnAGNPS Model (AnnAGNPS 모형을 이용한 수변구역의 비점오염물질 제거능 산정)

  • Park, Yun Hee;Kim, Tae Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.5
    • /
    • pp.22-31
    • /
    • 2006
  • AnnAGNPS model would be applied to simulate the pollutant removal capacity with the buffer strip in the Deachung reservoir watershed. In 2002, 2,270 tons of TN and 221 tons of TP were discharged from the nonpoint source pollutants in this watershed. During the rainy season, from June to September, 66.4% of TN and 71.9% of TP resulted from nonpoint source loads. AnnAGNPS model was also used to simulate the nutrients removal capacity from the buffer strip under the condition that the present landuse would be changed to forest. As the result of simulation, the removal rates of nutrients from the buffer strip of Daecheong reservoir watershed are 406 tons of TN, 39 tons of TP, which means reduction rates are TN 17.9%, TP 17.8%, respectively.

Pollutant Removal Efficiency in Oxidation Pond with Filamentous Algae Mat (사상성 조류매트 산화지의 수질정화효율)

  • Choi, Sun-Hwa;Jang, Jeong-Ryeol;Ahn, Yeul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.655-660
    • /
    • 2005
  • This study was carried out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat(FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow. The removal efficiencies of COD, SS, T-N and T-P in Oxidation Pond with Filamentous Algae Mat were -2.5%, 84.7%, 63.9% and 89.2%, respectively. The removal efficiencies of T-N and T-P which are nutrients index were high. Results of this study would help us to determine the possibility of using the water treatment on the contaminated small rural streams.

  • PDF