• 제목/요약/키워드: Pollutant loads

검색결과 361건 처리시간 0.032초

논문 - HSPF를 이용한 새만금 유역의 오염부하 특성 (Characteristics of Pollutant Loads in Saemangeum Watershed Using HSPF)

  • 정지연;신유리;최정훈;최인규;윤춘경;손영권
    • 한국관개배수논문집
    • /
    • 제18권2호
    • /
    • pp.54-65
    • /
    • 2011
  • This study was performed to analyze the influence of pollutant loads characteristics on the point and non-point sources in Saemangeum watershed area using Hydrological Simulation Program, Fortran (HSPF). The simulation items were flow, BOD, T-N, and T-P(2007~2010). The pollutant loads trend reflects the precipitation. Specifically, the point source loads were almost constant, but the non-point source loads were influenced in the precipitation. It was found that the effect of non-point source is larger than point source. The water quality had a clear trend by the season. However, pollutant loads did not show distinct seasonal changes. The reason is that the pollutant concentration is diluted by the increased flow at summer season. Therefore, it is important to control the non-point source in order to manage water quality in the region. For the management of Saemangeum lake, it is need to control of supplied pollutant loads from Saemangeum watershed.

  • PDF

합리적인 유역단위 오염부하량 산정방법 연구 (Calculation of Pollutant Load for Prediction of Pollutant Loads to Watershed)

  • 장재호;윤춘경;정광욱;김형철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.534-539
    • /
    • 2005
  • The purpose of this study is the introduction of pollutant loads's estimation into Saemangeum watershed area with M.E.'s guidebook for TMDL and GIS tool. To estimate reliable pollutants loads, it is necessary to think about characteristic of removal, discharge and runoff as time series. In this study, it was calculated for generation loads which be came from pollutant source, discharge loads which be reduced in the treatment facilities and delivery loads which be considered the self purification parameter and delivery distance. To assess the delivery distance handily, it was particularly estimated using Arc-GIS. It was met with good results that delivery loads of BOD, T-N and T-P was reflected to seasonal precipitation. Lastly to verify the estimated pollutant loads, HSPF developed by USEPA was applied to it. It was showed a relativity of observed to simulated data for flow, Temperature, DO, BOD, $NO_3^--N$ TN and TP. Consequantly, this delivery loads can make full use of model input data for prediction of pollutant loads.

  • PDF

발생부하원단위와 수치표고모형을 이용한 하천유역 오염부하량 산정 (Calculation of Pollutant Loadings from Stream Watershed Using Digital Elevation Model and Pollutant Load Unit Factors)

  • 양홍모;김혁
    • 한국조경학회지
    • /
    • 제29권1호
    • /
    • pp.22-31
    • /
    • 2001
  • The purpose of this study is to compare calculated pollutant loadings using pollutant load unit factors and vector type coverage, and expected mean concentration(EMC) and raster type of digital elevation model(DEM). This study is also focusing on comparison of the advantages and the disadvantages of the two methods, and seeking for a method of calculation of pollutant loadings using DEM. Estimation of pollutant inputs using pollutant load unit factors has limitations in identifying seasonal variations of pollutant loadings. Seasonal changes of runoffs should be considered in the calculation of pollutant loadings from catchments into reservoirs. Evaluation of pollutant inputs using runoff-coefficient and EMC can overcome these drawbacks. Proper EMC and runoff-coefficient values for the Koeup stream catchments of the Koheung estuarine lake were drawn from review of related papers. Arc/Info was employed to establish database of spatial and attribute data of point and non-point pollutant sources and characteristics of the catchments. ArcView was used to calculate point and non-point pollutant loadings. Pollutant loads estimated with either unit factors-coverages, i.e., pollutant load unit factors and vector coverages f point sources and land use, or EMC and digital elevation mode(DEM) were compared with stream monitoring loads. We have found that some differences were shown between monitoring results and estimated loads by Unit Factors-Coverage and EMC-DEM. Monthly variations of pollutant loads evaluated with EMC-DEM were similar to those with monitoring result. The method using EMC-DEM can calculate accumulated flows and pollutant loads and can be utilized to identify stream networks. A future research on correcting the difference between vector type stream using flow direction grid and digitalizing vector type should be conducted in order to obtain more exact calculation of pollutant loadings.

  • PDF

하천유역에서의 기저유출 분석을 통한 총질소 하천오염부하량 연구 (A Study of Total Nitrogen Pollutant Load through Baseflow Analysis at the Watershed)

  • 최윤호;금동혁;류지철;정영훈;김용석;전지홍;김기성;임경재
    • 한국물환경학회지
    • /
    • 제31권1호
    • /
    • pp.55-66
    • /
    • 2015
  • It has been well known that it is not easy to quantify pollutant loads driven by non-point source pollution due to various factors affecting generation and transport mechanism of it. Especially pollutant loads through baseflow have been investigated by limited number of researchers. Thus in this study, the Web-based WAPLE (WHAT-Pollutant Load Estimation) system was developed and applied at study watersheds to quantify baseflow contribution of pollutant. In YbB watershed, baseflow contribution with WWTP discharge is responsible for 49.5% of total pollutant loads at the watershed. Among these, pollutant loads through baseflow (excluding any WWTP discharge) is responsible for 61.7% of it. In GbA watershed, it was found that 58.4% is contributed by baseflow with WWTP discharge 2.9% and 97.1% is by baseflow. For NbB watershed (without WWTP discharge), 52.3% of pollutant load is transported through baseflow. As shown in this study, it was found that over 50.0% of TN (Total Nitrogen) pollutant loads are contributed by non-direct runoff. Thus pollutant loads contributed by baseflow and WWTP discharge as well as direct runoff contribution should be quantified to develop and implement watershed-specific Best Management Practices during dry period.

점토질 롬 밭과 논의 비점오염원 부하량 평가 (Evaluation of NPS Pollutant Loads from Clayey Loam Fields)

  • 최중대;권순국;권기석
    • 한국농공학회논문집
    • /
    • 제46권2호
    • /
    • pp.107-114
    • /
    • 2004
  • NPS pollutant loads from sandy clayey and clayey loam runoff plots were measured. Runoff plots were 2$\times$10 m in size and 8~10% in slope and paddy area was 4,620 $m^2$. Soybean, corn, tobacco and control (natural weed) were cultured. Precipitation during the growing season of June to October, 2002 was 869.5 mm. Runoff and water quality were measured more than 10 times during the measurements depending on the growing stage. Pollutants loads were estimated by using respective concentration and runoff volume. Runoff occurred when daily rainfall exceeded about 30 mm. The largest runoff was observed from the paddy but pollutant loads were larger from upland crops than those from paddy. SS loads from paddy and upland were 1.4 ton/ha/yr and 3.1~4.3 ton/ha/yr, respectively. COD loads 30 kg/ha/yr and 66~90 kg/ha/yr, T-N loads 13 kg/ha/yr and 14~23 kg/ha/yr, T-P loads 1 kg/ha/yr와 4 kg/ha/yr, nitrate nitrogen loads 1 kg/ha/yr and 4~8 kg/ha/yr, and phosphate phosphorus loads 0 kg/ha/yr and 4~6 kg/ha/yr, respectively. It was concluded that NPS pollutant loads from upland crop culture have greater impact on the quality of the receiving water body than those from paddy culture.

Tank모델에 의한 영일만 유입오염부하량의 계절변동 예측 (Seasonal Variation Estimation of Inflow Pollutant Loads of Yeong-il Bay by using Tank Model)

  • 이인철
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제6권3호
    • /
    • pp.63-71
    • /
    • 2003
  • 형산강 유역의 일별 하천유량과 오염부하량을 산정하기 위한 유역유출모형(강우-유출모형)인 Tank 모델을 구축하여 영일만으로 유입하는 오염부하량의 계절별 변동특성에 대해 검토하였다. 산정된 영일만으로 유입되는 형산강의 연평균 하천유량은 878.34×10/sup 6/㎥/year로 형산강 유역면적내 연평균 총강우량의 약 73%로 나타났다. 영일만내 유입되는 연평균 오염부하량은 각각 15.11 ton-COD/year, 23.24 ton-SS/year, 10.65 ton-TN/year, 0.54 ton-Tp/year로 산정되었다 또한 계절별 변동특성으로 하천유량이 증가하는 하계 6~7월과 춘계 10월에 유입오염부하량도 증가하는 경향을 보였다. 영일만내로 유입하는 주된 오염부하원은 형산강 하구인근에 위치한 포항시와 포항공단인 것으로 밝혀졌다. 따라서 영일만의 효율적인 수질관리를 위해서는 오염부하원으로부터의 오염부하량 저감대책수립이 요구된다.

  • PDF

Evaluation of Pollutant loads at Inflow Streams under Ara Waterway Basin

  • 한상윤;정종태
    • 도시과학
    • /
    • 제10권1호
    • /
    • pp.39-48
    • /
    • 2021
  • In this study, to evaluate the characteristics of the pollution in the major inflow tributaries and major environmental facilities in the watershed of Ara waterway, An inflow flow rate measurement and water quality analysis were conducted during dry and rainy seasons. In addition, the flow rate measurement, water quality analysis, and pollutant load at each monitoring point were compared and evaluated. Influx of BOD5, T-P and T-N into the tributaries of the ARA waterway watershed, excluding the Gulpo river watershed, during dry season were only 0.007%, 0.005% and 0.004% respectively of the incoming loads in the entire ARA waterway basin. In addition, it was confirmed that the discharge pollutant loads during rainfall event was about 440 times more for BOD5, about 545 times on T-P, and about 23 times on T-N in comparison to the pollutant loads during the dry days. When the Gulhyeon rubber dam was deflated, the discharged pollutant load during a rainfall was higher than the estimated load at the G7 monitoring point because the deposited pollutants from the upstream riverbed flowed down. Therefore, during a rainy season, it is necessary to manage the influx of high-load water pollutants from the overflow and deflation of the Gulhyun rubber dam as well as to find a strategy to reduce the pollutant loads in the Gulpo river watershed.

L-THIA 2012 유출 및 수질 자동 보정 모듈을 이용한 유출/비점부하량 산정 및 비점오염 부하량 포텐셜 등급화 (Evaluation of Runoff and Pollutant Loads using L-THIA 2012 Runoff and Pollutant Auto-calibration Module and Ranking of Pollutant Loads Potential)

  • 장춘화;금동혁;하준수;김경순;강동한;김극태;신동석;임경재
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.184-195
    • /
    • 2013
  • Urbanization from agricultural/forest areas has been causing increased runoff and pollutant loads from it. Thus, numerous models have been developed to estimate NPS loading from urban area and Long-Term Hydrologic Impact Analysis (L-THIA) model has been used to evaluate effects of landuse changes on runoff and pollutant loads. However, the L-THIA model could not consider rainfall intensity in runoff evaluation. Therefore, the L-THIA model, capable of simulating runoff using 10-minute rainfall data, was applied to the study areas for evaluation of estimated runoff and NPS. The estimated Nash-Sutcliffe coefficient (NSE) values were over 0.6 for runoff, BOD, TN, and TP for most sites and watershed. The calibrated model was further extended to other counties for pollutant load potential evaluation. Pollutant load potential maps were developed and target areas were identified. As shown in this study, the L-THIA 2012 can be used for evaluation runoff and pollutant loads with limited data sets and its estimation could be used in identifying pollutant load hot spot areas for implementation of site-specific Best Management Practices.

최적화기법을 이용한 황구지천유역의 오염부하량 할당 (Waste Load Allocation of Hwanggujicheon Watershed Using Optimization Technique)

  • 조재현;정욱진;이종호
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.728-737
    • /
    • 2005
  • Water quality of the Hwanggujicheon is poor because of the rapid housing and development in the large area of the basin. Establishment of water quality management strategy, based on the pollution sources survey and pollutant loads estimation, has to be established for the preservation of the stream water quality of the region. In this study, waste load allocation model to achieve the water quality goal of the stream and the optimization of pollutant load reduction, was developed. Nonpoint pollutant loads calculated by runoff model in the previous study are utilized for pollutant loads estimation of the drainage areas in this study. From the application result of the allocation model, water quality goals of the Hwanggujicheon that can be achieved as a matter of fact are BOD 8 mg/L. To achieve these goals, 23% of effluent BOD loads have to be reduced in the basin.

Characteristics of Pollutant Loads and Water Quality in Kwangyang Bay, Korea

  • Lee Dae-In;Park Chung-Kil;Cho Hyeon-Seo
    • Fisheries and Aquatic Sciences
    • /
    • 제6권3호
    • /
    • pp.149-154
    • /
    • 2003
  • The characteristics of pollutant loads from the various sources and seawater quality in Kwangyang Bay were evaluated. Total flow rate was estimated to be $10,868,066.8 m^3/day$ with a flow rate of R2l (the Seomjin River) as the highest one. Total COD, TN and TP loads of the input rivers and the ditches were about 27,591.8, 25,029.6 and 586.4 kg/day, respectively. Wastewater discharging loads was the greatest contributors to pollutant loads in the inner part of Kwangyang Bay. COD values in the inner part of the bay was over 3.0 mg/L, which exceeded the seawater quality criteria III of Korea. The average values of DIN and DIP were 8.62 ${\mu}gN/L\;and\;1.26\;{\mu}gP/L$, respectively. The limiting factor for algal growth was DIN. In he total discharging loads of the watershed from unit loading estimations, BOD, TN and TP were 9,132.3, 2,727.2 and 304.2 kg/day, respectively. In addition, municipal sewage by the population as pollution sources and the city of Kwangyang as administrative district had the highest loads. For a appropriate water quality recovery of Kwangyang Bay, it is suggested that it is essential to estimate reduction rate of total pollutant loads by water quality modeling.