A Study of the Development of the Temporary Transformer System for the Replacement of Bum-out Pole Transformer (소손 주상변압기 교체를 위한 임시송전시스템 개발에 관한 연구)

  • Lee, Jung-Kyun;Yun, Young-Mo;Jeun, Si-Sik;Lee, Jae-Heon;Jeong, Dong-Ju;Park, Yong-Beom;Kim, Jeom-Sik;Jo, Seong-Mun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.43-46
    • /
    • 2009
  • This paper describes a development of the temporary transformer system and method. The failure causes are genrally divided into problems in manufacturing, mounting and operating. To replace the bum-out pole transformers developed various facilities, power cable clamp, the control panel of self-sensing device and voltage connection box etc. That is more effective to establish the emergency transmission systems for the non interruption replacement of distribution transformers.

  • PDF

Enhancement of Rubber Gasket Material for Pole Transformer (주상변압기 밀봉재질 개선을 위한 수명시험 방법)

  • Song, Dong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1770-1775
    • /
    • 2010
  • An acceleration life test for rubber gasket of pole transformer was performed. The Arrhenius method was applied as an accelerated degradation test. The failure mode was considered as an elongation, and the failure mechanism is counted as a heat. It is found that both the current material(NBR: Nitrile Butadiene Rubber) and recommended alternative material(HNBR: Hydrogenated Nitrile Butadiene Rubber) have the same Weibull distribution as a life characteristic. For life expectation 95% reliability level of characteristic life is used at using temperature. The test results for NBR and HNBR are 7.7 years and 28.0 years on $50^{\circ}C$ of using temperature, respectively.

Analysis of Aging Characteristics in Oil Immerged Pole Transformer (과부하 및 경년 변압기 절연유 열화 특성 분석 연구)

  • Lee, Byung-Sung;Song, Il-Keun;Lee, Jae-Bong;Park, Dong-Bea;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.203-207
    • /
    • 2002
  • In order to evaluate the aging of mineral oil immersed distribution transformers, it gathered some insulation oil in over loaded and long time(exceed their service life, 13yrs.) aged transformers in the field, we measured moisture content, acid number, dielectric strength of the oil as defined in KS C 2101 standard. And also, it had been measured dielectric constant, specific resistant, $tan{\delta}$ on aged transformer oil at from $10^{\circ}C$ to $130^{\circ}C$. These results are compared with a new mineral oil. From this study, it can be considered that the analysis of mineral oil may be suitable for evaluation of life expectancy in distribution transformers

  • PDF

The Temperature Distribution and Thermal Stress Analysis of Pole Mold transformer (주상용 몰드변압기의 온도분포와 열응력 해석)

  • 조한구;이운용;한세원;김석수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.297-301
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The one body molding model (Model 1) and air duct model (Model 2) are designed and their temperature distribution are analysed. The temperature rise value is about 105.5 deg in the model 1 and 65.28 de in the model 2. The temperature change of secondary winding is more than primary winding according to load ratio. The concentration part of Von Mises Stress occurs at interface between glass fiber and epoxy.

  • PDF

The Development of Distribution Transformer Remote Monitoring System using CATV Cable (CATV회선을 이용한 배전용 변압기 부하의 원격감시시스템 개발)

  • Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.939-942
    • /
    • 1998
  • This paper presents the process on the construction for the remote distribution pole transformer monitoring system. Especially, this system uses CATV cable as communication media which is located in KEPCO's main distribution line. It has four major components such as sensor for measuring secondary voltage and currents of distribution transformer, RF modem for data modulating/de-modulating, communication media for sending/receiving of data, and pc server for monitoring the results of sensing or computing information. This paper also describes the configuration of these each component's configuration and its functions.

  • PDF

Development of Diagnosis Device for Pole and Pad Transformer using Wireless Data Communication (무선 데이터 통신을 이용한 주상 및 지상 변압기 진단 장치 개발)

  • 윤용한;민경래;최도혁;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.85-92
    • /
    • 2000
  • This paper has developed the system that can monitor the distribution transformers(pole and pad) using simplified deterioration detecting sensor in oil and wireless data communication. This system is made up by deterioration detecting sensor, oil level measuring system, deterioration measuring system and communication unit. To prove the usefulness of the system, the paper compared and analyzed the system with the existed system, and after studying the correlation of the both, the result proved goodness of the new system. The proposed monitoring system, when it is used on the pole and pad transformer, would make the reliable diagnoses possible with less rate.

  • PDF

The Study of the Design Tests for Current Capability according to ANSI (ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

Dielectric Characteristic Analysis of Thermally Aged Insulating Oil for Transformers (열적열화된 변압기용 절연유의 유전특성 분석)

  • Jung, J.W.;Lee, B.S.;Song, I.K.;Park, J.S.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1594-1596
    • /
    • 2001
  • The purpose of this paper is to provide the fundamental data which can be used for the design of pole transformers. For the purpose, electrical characteristics of aged mineral oil and silicone oil were analyzed by comparing with the results of virgin ones. For the experiment, an oil bath which can keep constant temperature was constructed to thermally deteriorate the specimens. And transformer materials were put together in the bath according to the their ratio in weight in the pole transformer. And the parameters such as relative permittivety, tan$\delta$ and specific resistance were measured. As a results, the permittivity of silicone oil was higher than that of mineral oil, and its decreasing rate with temperature was also higher. In addition, it was found that tan$\delta$ and specific resistance of virgin and aged oil began to differ at similar temperature.

  • PDF

A Study on Suggestion of Insulating Oil Ageing Degree in Pole-Transformer by Absorbance (흡광도법에 의한 주상변압기 절연유의 열화판정기준 설정에 관한 연구)

  • Lee, Dong-Zoon;Jung, Jong-Uk;Kim, Kyung-Hwa;Kwak, Hee-Ro;Yun, Yong-Ja
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1851-1853
    • /
    • 1996
  • In this paper the criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Ageing of insulating oil caused the change in absorbances of oil os well os the deterioration of electrical properties of oil. By comparing the electrical properties such as $tan{\delta}$ and breakdown voltage with the UV-Visible absorbances of oil, criteria for absorbance values determining oil condition were established. This UV-Visible spectrophotometric method might be applied in ageing analysis of oil and be expected to replace the current method.

  • PDF