• Title/Summary/Keyword: Polarized current

Search Result 137, Processing Time 0.03 seconds

Development of Magnetized Ferromagnetic Stainless Steel Acupuncture Needle (강자성(强磁性) 스테인리스강(鋼) 자화침(磁化鍼)의 개발)

  • Hong, Do Hyun
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.21-30
    • /
    • 2014
  • Objectives : Manufacturing and manipulation techniques of acupuncture can be interpreted as an induced electromagnetic viewpoint, as proposed in previous study. Considering from this point of view, the magnetization of needles should be essential to enhance the electromagnetic effects during the behavior of the acupuncture needling. Methods : The current disposable needles are made of non-magnetic stainless steels, so ferromagnetic materials were searched as suitable substitutes. Meanwhile, at the practical view, stainless steels are very available for the several superior properties like as corrosion resistance, strength, etc., magnetic stainless steels were first investigated. Some types of them still preserved the ferromagnetic properties of iron, so trial needles were made with them. And then magnetization of them were followed. Results : Among the hundreds types of stainless steels, martensitic or ferritic ones are ferromagnetic. The needles made with these ferromagnetic wires were magnetized, and polarized by magnetizer, and their magnetic properties were improved. Moreover, in addition to the superiority of the magnetism, the electrical and thermal conductivities of them were even better than those of the current austenitic stainless steels. Conclusions : Through the developmental study based on the electromagnetic viewpoint, the magnetized and polarized acupuncture needles were completed. This means that these needles having improved magnetism can be used to improve the electromagnetic needling effects, and moreover, their superiorities in the electrical and thermal conductivities can also give another benefits in treatments of electrical or warm needling.

Polarization Ellipticity of Micro-photoluminescence in a Single GaAs/AlGaAs Quantum Ring

  • Kim, Minju;Jang, Juyeong;Lee, Seunghwan;Song, Jindong;Kyhm, Kwangseuk
    • Current Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.72-76
    • /
    • 2021
  • The polarized micro-photoluminescence spectrum was analyzed to investigate the anisotropic localized states in a single GaAs quantum ring. An energy difference of ~0.1 meV was observed from the perpendicularly polarized spectrum measured by a pair of linear analyzers. Spectral dependence of the polarized emission was also characterized in terms of rotation and ellipticity angles using four Stokes parameters. While the rotation angle indicates the symmetric axis of an anisotropic quantum ring with a small variation (± 2°), the ellipticity angle varies from 7.4° down to -2.5°. We conclude that optical anisotropy and birefringence are induced by the crescent-like lateral shape of localized states.

Polarization Distortion and Compensation of Circularly Polarized Emission from Chiral Metasurfaces

  • Yeonsoo Lim;In Cheol Seo;Young Chul Jun
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.147-156
    • /
    • 2023
  • Circularly polarized (CP) emission can be achieved by integrating emissive materials into chiral metasurfaces. Such CP light sources in integrated device platforms are desirable for important potential applications. However, the exact characterization of the polarization state in CP emission may include some errors because of the unwanted polarization distortion caused by optical components (e.g., beam splitter) in the optical setup. Here, we consider CP emission measurements from chiral metasurfaces and characterize the polarization distortion caused by the beam splitter. We first detail the procedures for the Stokes parameters and Mueller matrix measurements. Then, we directly measure the Mueller matrix of the beam splitter and retrieve the original polarization state of CP emission from our metasurface sample. Using the measured Mueller matrix of the beam splitter, we specifically identify what contributes to polarization distortion in CP emission. Our work may provide useful guidelines for the characterization and compensation of polarization distortion in general Stokes parameter measurements.

Multi-spectral Mueller Matrix Imaging for Wheat Stripe Rust

  • Yang Feng;Tianyu He;Wenyi Ren;Dan Wu;Rui Zhang;Yingge Xie
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.192-200
    • /
    • 2024
  • Wheat stripe rust, caused by Puccinia striiformis, has reduced winter wheat yield globally for ages. In this work, multi-spectral Mueller matrix imaging with 37 measurements using the method of double rotatable quarter-wave plates was used to investigate wheat stripe rust. Individual Mueller matrix measurements were performed on incident monochromatic light with nine bands in the range of 430 to 690 nm. As a result, it was found that the infected area absorbed linearly polarized light and was sensitive to circularly polarized light in the spectral domain. Both linear depolarization and linear diattenuation images distinguished between wheat stripe rust and healthy tissue. The responsiveness of stripe rust to polarized light reveals the potential of using polarization imaging to detect plant diseases. This further suggests that the multi-spectral Mueller matrix imaging system provides us with an alternative approach to agricultural disease detection.

Electrical Characteristics of Step-down Piezoelectric Transformer (강압용 압전변압기의 전기적 특성)

  • 신훈범;유영한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.389-392
    • /
    • 2001
  • In this paper, we have explained electrical characteristics of a step-down Rosen type piezoelectric transformer for AC-adapter. When the electric voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, then output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformer were measured under the various conditions of loads and frequencies. We measured resonant frequency from impedance curve. It was shown from experiments that output voltage has increased and resonant frequency has changed according to various resistor loads. Output current has changed inversely proportional to resistances.

  • PDF

Effect of spin-polarized current injection on pair tunneling properties of $Bi_2$$Sr_2$Ca$Cu_2$$O_{8+x}$ intrinsic Josephson junctions

  • Shin, Ho-Seop;Lee, Hu-Jong;Do Bang;Nguyen Khac Mac
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.5-8
    • /
    • 2003
  • We studied the effect of spin injection on tunneling conduction properties of intrinsic Josephson junctions formed in $Bi_2$$Sr_2$$CaCu_2$$O_{ 8+x}$ single crystals. properties of an identical stack (10${\times}$5.0${\times}$0.030 $\mu\textrm{m}^3$) of intrinsic Josephson junctions were compared for the bias current injected through Au and Co electrodes. The suppression of the superconducting gap in the $_2$ double layers and the interlayer Josephson critical current was manifested in the tunneling current-voltage characteristics of the stacks. This effect appears to be caused by the pair breaking associated with spin-polarized carriers injected from the Co electrode into the $Bi_2$$Sr_2$$_2$O$CaCu_{ 8+x}$ single crystal. This study may provide valuable information on clarifying the mechanism of high- $T_{c}$ superconductivity.y.y.

  • PDF

Polarization Phase-shifting Technique for the Determination of a Transparent Thin Film's Thickness Using a Modified Sagnac Interferometer

  • Kaewon, Rapeepan;Pawong, Chutchai;Chitaree, Ratchapak;Bhatranand, Apichai
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.474-481
    • /
    • 2018
  • We propose a polarization phase-shifting technique to investigate the thickness of $Ta_2O_5$ thin films deposited on BK7 substrates, using a modified Sagnac interferometer. Incident light is split by a polarizing beam splitter into two orthogonal linearly polarized beams traveling in opposite directions, and a quarter-wave plate is inserted into the common path to create an unbalanced phase condition. The linearly polarized light beams are transformed into two circularly polarized beams by transmission through a quarter-wave plate placed at the output of the interferometer. The proposed setup, therefore, yields rotating polarized light that can be used to extract a relative phase via the self-reference system. A thin-film sample inserted into the cyclic path modifies the output signal, in terms of the phase retardation. This technique utilizes three phase-shifted intensities to evaluate the phase retardation via simple signal processing, without manual adjustment of the output polarizer, which subsequently allows the thin film's thickness to be determined. Experimental results show that the thicknesses obtained from the proposed setup are in good agreement with those acquired by a field-emission scanning electron microscope and a spectroscopic ellipsometer. Thus, the proposed interferometric arrangement can be utilized reliably for non-contact thickness measurements of transparent thin films and characterization of optical devices.

Electrical Charateristics of Step-down Piezoelectric Transformer

  • Shin Hoonbum;Ahn HyungKeun;Han Deuk-Young
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.47-51
    • /
    • 2001
  • In this paper, we have explained electrical characteristics of a step-down Rosen type piezoelectric transformer for AC-adapter. When the electric voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, then output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. From the piezoelectric direct and converse effects, symbolic expressions between the electric inputs and outputs of the step-down piezoelectric transformer have derived with an equivalent circuit model. With the symbolic expressions, load and frequency characteristics have discussed through simulation. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformers were measured under the various conditions of loads and frequencies. First we measured resonant frequency from impedance curve and got equivalent impedance value of the piezoelectric transformer from admittance plot. It was shown from experiments that output voltage has increased and resonant frequency has changed according to various resistor loads. Output current has decreased inversely proportional to changing of loads. Moreover, the measured values of output voltage and current are well agreed with the simulated values of the proposed equivalent circuit model.

  • PDF

The Fast Convergent Solution of E-Polarized Reflection Coefficient by a Perfect Conductor Strip Grating (완전도체 스트립 회절격자에 의한 E-분극 반사계수의 급속한 수염해)

  • Uei-Joong Yoon
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 1995
  • The E-polarized scattering problems by a perfect conductor strip grating are analyzed by the method of moments. For an E-polarization the induced surface current density is expected to blow up at the strip both edges. Then the induced surface current density on the strip is expanded in a series of multiplication of Ultraspherical ploynomials with zeroth order and functions with appropriate edge boundary condition. The numerical results for current density and reflection cofficient are compared with other functions, it is shown that numerical results better improves the convergence of the moment method soulutions with general incident angles than the existing several other functions. The sharp variation points in the magnitude of geometric-optical reflection coefficient can be moved by varying the incident angle, strip width, and strip spacing.

  • PDF