• 제목/요약/키워드: Polarization test

검색결과 555건 처리시간 0.023초

An Efficient Adaptive Polarimetric Processor with an Embedded CFAR

  • Park, Hyung-Rae;Kwag, Young-Kil;Wang, Hong
    • ETRI Journal
    • /
    • 제25권3호
    • /
    • pp.171-178
    • /
    • 2003
  • To improve the detection performance of surveillance radars with polarization diversity, we developed an adaptive polarimetric processor and compared it with other polarimetric processors. We derived our adaptive polarimetric processor, called the polarization discontinuity detector (PDD), from the generalized likelihood ratio (GLR) test principle for the unspecified target component. We derived closed-form expressions of its probabilities of detection and false alarm, and compared its performance to that of the adaptive polarization canceller (APC) and Kelly's GLR processor. The PDD had a performance similar to Kelly's GLR in Gaussian clutter, and both the PDD and Kelly's GLR, which have embedded constant false alarm rates (CFARs), outperformed the APC, especially when the target polarization state was close to the clutter's polarization state. The important difference is that the PDD is much simpler than Kelly's GLR for hardware/software implementation, because the PDD does not require a costly two-parameter filter bank to cover the unknown target polarization state as Kelly's GLR does.

  • PDF

인발률에 따른 자동차 냉각 배관용 Al 합금의 부식 특성에 관한 연구 (Effect of Drawing Rate on the Corrosion Behavior of Al Alloy Tubes for Automotive Cooling System)

  • 박병준;김정구;안승호;곽동호;손현수
    • 대한금속재료학회지
    • /
    • 제46권8호
    • /
    • pp.489-494
    • /
    • 2008
  • The effect of drawing rate on the electrochemical properties of 3003 Al alloys in 5 wt.% NaCl solution was investigated by electrochemical techniques (potentiodynamic polarization test, potentiostatic polarization test, electrochemical impedance spectroscopy (EIS)) and surface analyses (OM, SEM, EDS). Four kinds of automotive pipe materials were prepared (raw material, drawing rate = 5, 10, 15%). As the drawing rate of Al alloy tube increased, the pitting corrosion resistance increased due to the enrichment of Al oxides on the surface.

Corrosion Evaluation of Epoxy-Coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests

  • Choi, Oan-Chul;Jung, Si-Young;Park, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.3-9
    • /
    • 2006
  • Five slab specimens with predefined cracks are examined to evaluate the corrosion behavior of epoxy-coated bars in chloride contaminated concrete, using linear polarization method. The test specimens were subjected to alternating weekly cycles of ponding in a salt solution and drying for 48 weeks. Test results show that the current density of the specimen of normal steel bars becomes 0.715 ${\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy-coated bars are significantly below 0.1 ${\mu}A/cm^2$ and the bars appears to be in passive condition. The damaged epoxy-coated bars with a corrosion inhibitor of calcium nitrite showed a corrosion rate of 0.110 ${\mu}m/year$ or 56 percents of the corrosion rate of damaged epoxy-coated specimen without such an inhibitor, 0.195 ${\mu}m/year$. However, the corrosion rates of specimens containing the other two corrosion inhibitors, a combination of amines and esters or mixtures of organic alkenyl dicarboxyl acid salts are quite equivalent to the control specimen. The research technique of linear polarization resistance method has proven itself to be useful in measuring corrosion rates of reinforcement in concrete.

전기화학적 분극법에 의한 1.0Cr-0.5Mo강의 경년열화 평가에 관한 연구 (A study on the evaluation for material degradation of 0.0Cr-0.5Mo steel by a electrochemical polarization method)

  • 나의균;김훈;이종기
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.177-189
    • /
    • 1998
  • The contents of this paper include a non-destructive technique for evaluating the degradation of the boiler superheater tube in a fossil power plant through an electrochemical polarization test. Correlation between Ip of polarization parameter and SP-DBTT for the superheater tubes in long-term use was obtained. 1.0Cr-0.5Mo steel was degraded by softening, and the degree of degradation was dependent upon carbides with Cr and Mo elements. Since brittle fracture at low temperature and ductile fracture mode at high temperature were shown, similarity between standard Charpy and small punch tests could be found. In addition, SP-DBTT showing the degree of degradation was higher, as the time-in use of the materials got longer. Electrolyte including picric acid of 1.3 g in distilled water of 100ml at 25.deg. C temperature and sodium tridecylbenzene sulfonate with 1g could be applied to evaluate the degradation of 1.0Cr-0.5Mo steel by means of the electrochemical polarization test. Ip and Ipa values measured through the electrochemical test are the appropriate parameters for representing the degradation of the superheater tube(1.0Cr-0.5Mo steel) for the fossil power plant. It is poassible to evaluate the degradation of materials with different time histories electrochemically, by Ip value only, at field test.

크롬도금의 틈부식 거동에 관한 연구 (A Study on the Crevice Corrosion Behavior of Chromium Plating)

  • 곽남인;임우조
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.324-328
    • /
    • 2003
  • This study was made on the crevice corrosion behavior of chromium plating in fresh water. Under the various crevice, the electrochemical polarization test of chromium plating was carried out. Results are discussed In terms of corrosion potential, polarization resistance, corrosion current density and cathodic control of chromium plating.

흡수식냉동기용 열교환기 세관의 부식에 관한 연구 (The Study of Corrosion of Heat Exchanger Tube for Absorption Refrigeration Machine)

  • 임우조;정기철;윤병두
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.147-152
    • /
    • 2002
  • This paper was studied on corrosion of heat exchanger tube for absorption refrigeration machine. In the 62 % lithium bromide solution at $60^{\circ}C$, polarization test of Cu, Al-brass, 10 % cupro nickel(90-10 % Cu-Ni) and 30 % cupronickel(70-30 % Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for absorption refrigeration machine were considered. The main results are as following: The open circuit potential of Al-brass tube becomes less noble than that of Cu tube, corrosion current density of that becomes lower than Cu tube. The open circuit potential of cupronickel tube is more noble than that of Cu tube, corrosion current density of that is controlled than Cu tube. The passivation critical current of 30 % Cu-Ni tube is lower than that of 10 % Cu-Ni tube, potential of passive region of that is more wide than 10 % Cu-Ni tube.

  • PDF

DIVERSITY DESIGN FOR SENSOR DATA ACQUISITION AT COMS SOC

  • Park, Durk-Jong;Koo, In-Hoi;Ahn, Sang-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.479-481
    • /
    • 2007
  • COMS will transmit its observed data, Sensor Data, through L-Band with linear polarization. To avoid link loss caused by polarization discrepancy between satellite and SOC DATS, the L-Band antenna at SOC DATS should be linearly polarized. However, SOC DATS is supposed to share single antenna with SOC TTC, so the antenna should be circularly polarized. To cope with about 3dB loss, SOC DATS is designed to receive Sensor Data through two orthogonal circular polarizations, RHCP (Right-Hand Circular Polarization) and LHCP (Left-Hand Circular Polarization). Eventually, SOC DATS can obtain 2.6dB of combining gain through diversity combiner in MODEM/BB. This paper presents the verification on the diversity combining of SOC DATS with test configuration and results in depth.

  • PDF

Evaluation of Hydrogen Sulfide Corrosion Inhibitors for Wet Gas Pipeline Steel

  • Huy, Vu Dinh;Thoa, Nguyen Thi Phuong;Phong, Tran Quoc;Hoang, Nguyen Thai
    • Corrosion Science and Technology
    • /
    • 제4권3호
    • /
    • pp.95-99
    • /
    • 2005
  • Wheel test and potentiodynamic polarization methods were used to evaluate the relative effectiveness of some hydrogen sulfide corrosion inhibitors for the wet gas pipeline API 5L grade X 65 steel. Five commercially corrosion inhibitors have been studied in the deoxygenated produced water solutions containing 10 ppm and 100 ppm of hydrogen sulfide. Based on the experiment results the steel corrosion inhibition mechanism in discussed and two most effective corrosion inhibitors are selected.

크롬도금의 부식-마멸에 미치는 산성환경의 영향 (The Effect of Acidic Environments on the Corrosion-Wear of Cr Plating)

  • 곽남인;임우조
    • Tribology and Lubricants
    • /
    • 제19권4호
    • /
    • pp.211-216
    • /
    • 2003
  • This paper was studied on the corrosion and corrosion-wear behavior of chromium (Cr) plating in the acidic environments. In the various pH of acidic solutions, the electrochemical polarization test and wear-corrosion test of Cr plating were carried out. And thus potential, corrosion current density and corrosion-wear loss behaviour of Cr plating are investigated.

전기구리도금에 미치는 Mercapto화합물의 전기화학적 특성 (The Electrochemical Characteristics of Mercapto Compounds on the Copper Electroplating)

  • 손상기;이유용;조병원;이재봉;이태희
    • 전기화학회지
    • /
    • 제4권4호
    • /
    • pp.160-165
    • /
    • 2001
  • 황산원자를 포함하는 mercapto화합물은 도금시 전착속도를 증가시키는 첨가제로 알려져 있는데, 이 중 4가지의 mercapto 화합물을 선정하여 농도를 변화시켜가며 Hull cell test, Haring-Blum cell test, cathodic polarization, EQCM(Electrochemical Quartz Crystal Microbalance)등을 이용하여 도금특성 및 throwing power를 알아보았다. Cathode polarization 및 EQCM을 통한 구리 전착량을 알아본 결과 4가지의 mercapto 화합물 중 3-mercapto-1-propanesulfonic acid가 activator로서 가장 적당하였으며, 그 농도가 20 ppm에서 throwing power를 증가시키고, 농도 및 활성 과전압이 오직 $Cl^-$만 포함되었을 때보다 cathodic scan시 100 mV 만큼 shift되어 증착속도를 증가시킴을 알 수 있었다.