• Title/Summary/Keyword: Polarization Observation

Search Result 110, Processing Time 0.024 seconds

Ricean Bias Correction in Linear Polarization Observation

  • Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.267-271
    • /
    • 2011
  • I developed an enhanced correction method for Ricean bias which occurs in linear polarization measurement. Two known methods for Ricean bias correction are reviewed. In low signal-to-noise area, the method based on the mode of the equation gives better representation of the fractional polarization. But a caution should be given that the accurate estimation of noise level, i.e. ${\sigma}$ of the polarized flux, is important. The maximum likelihood method is better choice for high signal-to-noise area. I suggest a hybrid method which uses the mode of the equation at the low signal-to-noise area and takes the maximum likelihood method at the high signal-to-noise area. A modified correction coefficient for the mode solution is proposed. The impact on the depolarization measure analysis is discussed.

Anodic Polarization Characteristics in Ti-20%Zr(-5%Cr) Alloys for Dental Castings (치과주조용 Ti-20%Zr(-5%Cr)합금의 양극분극특성)

  • Jung, Jong-Hyun;Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • Ti-20%Zr(-5%Cr) alloys not containing harmful Al and V were newly designed in order to reveal their possibility for dental casting and melted in an arc melting and casting furnace under Ar atmosphere. The corrosion resistance was studied by anodic polarization test. From the observation of anodic polarization behavior, it was found that the corrosion resistance was markedly increased by the addition of Cr. The corrosion resistance of Ti-20%Zr-5%Cr alloy was superior to that in Ti-6%Al-4%V alloy but almost similar to that in CP Ti using in market place today.

  • PDF

A Broadband W-band Orthomode Transducer for KVN Polarization Observations

  • Chung, Moon-Hee;Je, Do-Heung;Kim, Seung-Rae
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.345-353
    • /
    • 2013
  • A W-band Orthomode Transducer (OMT) has been developed for Korean VLBI Network (KVN) polarization observation. The OMT design was based on E-plane split-block technique using septum structure. 3-dimensional electromagnetic simulation was fully employed to optimize the performance of the OMT. Measurements of the fabricated OMT show that the return losses for the vertically and horizontally polarized modes are better than -20 dB across 80 ~ 108 GHz and the insertion losses for the both modes are less than 0.47 dB. The cross-polarization level of the OMT is less than -30 dB. The bandwidth of the developed OMT is estimated as around 30%.

Study of Magnetohydrodynamic Turbulence Using Multi-frequency Synchrotron Polarization Observations

  • Lee, Hyeseung;Cho, Jungyeon;Lazarian, Alex
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.44.2-44.2
    • /
    • 2019
  • Turbulent motions perturb magnetic field lines and produce magnetic fluctuations. The perturbations leave imprints of turbulence statistics on magnetic field. Observation of synchrotron radiation is one of the easiest ways to study turbulent magnetic field. First, we obtained the spatial spectrum of synchrotron polarization so that shows how the spectrum is affected by Faraday rotation and how to recover the statistics of underlying turbulence magnetic field. Since polarized synchrotron intensity arising from magnetized turbulence are anisotropic along the direction of mean magnetic field. Secondly, we studied quadrupole ratio to quantitatively describe the degree of anisotropy introduced by magnetic field at multi-wavelengths. This work demonstrated that the spectrum and quadrupole ratio of synchrotron polarization can be very informative tools to get detailed information about the statistical properties of MHD turbulence from radio observations of diffuse synchrotron polarization.

  • PDF

Detection of AGN outflows in micro-arcsec scales

  • Oh, Junghwan;Trippe, Sascha;Krichbaum, Thomas;Sohn, Bong Won;Bremer, Michael
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.43.1-43.1
    • /
    • 2013
  • We report the preliminary results of our GMVA(Global mm VLBI Array) observation at the frequency of 86 GHz. Observation were made in the dual polarization mode (LCP and RCP), to produce the polarimetric maps with the maximum angular resolution which the array is capable of. We aim to link the source-integrated AGN polarization properties with the polarized spatial source structure, by mapping the polarized "fine structure" of the target AGN. We selected 2 targets, 0954+658 and 0716+714, which (1) have been observed multiple times by the PdBI polarimetric monitoring program; (2) have sufficient integrated fluxes ($S_{90GHz}$ > 1 Jy) ; (3) are close enough to resolve the source structure < 1 pc with given angular resolution ; and (4) are located at high northern declination for good UV coverages. As preliminary results, we present LL and RR polarized images of each target with the maximum angular resolution of ${\sim}60{\mu}as$. Extended structures, probably the jet outflows, are discovered in both sources.

  • PDF

Deep polarization observations of a ram pressure stripped galaxy, NGC 4522

  • Choi, Woorak;Chung, Aeree;Kim, Chang-goo;Lee, Bumhyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2020
  • We present high-resolution, high-sensitivity continuum data of NGC 4522 observed at 3 cm (X-band) and 10 cm (S-band) in full polarization mode using the JVLA. This observation has 2 - 4 times better spatial resolution and 2 - 5 times better sensitivity compared to previous continuum observations. NGC 4522 is a Virgo spiral galaxy undergoing active ram pressure stripping. This galaxy is particularly well known for the CO emission detected outside its stellar disk, some of which coincides with the extraplanar HI gas and Halpha patches. The major goal of our JVLA observation is to leverage our understanding of the influence of the ram pressure on the general ISM field and multi-phase medium. By combining our new deep radio continuum data and previous observations, we will investigate how the B-field properties can be affected by the ram pressure, and what roles the B-field plays in the stripping process of the multi-phased ISM and in the star formation activity when the ram pressure is present.

  • PDF

Toward Next Generation Solar Coronagraph: Diagnostic Coronagraph Experiment

  • Cho, Kyung-Suk;Yang, Heesu;Lee, Jaeok;Bong, Suchan;Choi, Seonghwan;Kim, Jihun;Park, JongYup;Park, YoungDeuk;Kim, Yeon-Han
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.42.2-42.2
    • /
    • 2019
  • Korea Astronomy and Space Science Institute (KASI) has been developing a next-generation coronagraph (NGC) in cooperation with NASA to measure the coronal electron density, temperature, and speed using four different filters around 400 nm. To demonstrate technology for the measurement through the 2017 total solar eclipse across the USA, KASI organized an expedition team to demonstrate the coronagraph measurement scheme and the instrumental technology. The observation site was in Jackson Hole, Wyoming, USA. We built an eclipse observation system, so-called Diagnostic Coronal Experiment (DICE), which is composed of two identical telescopes to improve a signal to noise ratio. The observation was conducted with 4 wavelengths and 3 linear polarization directions according to the planned schedule in a limited total eclipse time of about 140 seconds.Polarization information of corona from the data was successfully obtained but we failed to get the coronal electron temperature and speed information due to a low signal-to-noise ratio of the optical system. In this study, we report the development of DICE and observation results. TSE observation and analysis by using our own developed instrument gave an important lesson that a coronagraph should be carefully designed to archive the scientific purpose. This experience through TSE observation will be very useful for a success of NASA-KASI joint missions called the Balloon-borne Investigation of the Temperature and Speed of Electrons in the Corona (BITSE) and COronal Diagnostic EXperiment (CODEX).

  • PDF

Detecting the Signature of the First Stars through Planck CMB Polarization Observation

  • Ahn, Kyungjin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.76.2-76.2
    • /
    • 2012
  • We present the first simulations of cosmic reionization that include the first stars and their radiative feedback that limited their formation, in a volume large enough to capture the spatial variations that affected the process and its observability. We show hat these first stars made reionization begin much earlier than without, and was reatly extended, which boosts the intergalactic electron-scattering optical depth and the large-angle polarization fluctuations of the cosmic microwave background (CMB) significantly. Although within current WMAP uncertainties, this will enable Planck see he signature of the first stars at high redshift, currently undetectable by other probes.

  • PDF

TOWARD A NEXT GENERATION SOLAR CORONAGRAPH: DIAGNOSTIC CORONAGRAPH EXPERIMENT

  • Cho, Kyung-Suk;Yang, Heesu;Lee, Jae-Ok;Bong, Su-Chan;Kim, Jihun;Choi, Seonghwan;Park, Jongyeob;Cho, Kyuhyoun;Baek, Ji-Hye;Kim, Yeon-Han;Park, Young-Deuk
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.4
    • /
    • pp.87-98
    • /
    • 2020
  • The Korea Astronomy and Space Science Institute (KASI) has been developing a next-generation coronagraph (NGC) in cooperation with NASA to measure the coronal electron density, temperature, and speed simultaneously, using four different optical filters around 400 nm. KASI organized an expedition to demonstrate the coronagraph measurement scheme and the instrumental technology during the 2017 total solar eclipse (TSE) across the USA. The observation site was in Jackson Hole, Wyoming, USA. We built an eclipse observation system, the Diagnostic Coronal Experiment (DICE), composed of two identical telescopes to improve the signal-to-noise ratio. The observation was conducted at four wavelengths and three linear polarization directions in the limited total eclipse time of about 140 seconds. We successfully obtained polarization data for the corona but we were not able to obtain information on the coronal electron temperature and speed due to the low signal-to-noise ratio of the optical system and strong emission from prominences located at the western limb. In this study, we report the development of DICE and the observation results from the eclipse expedition. TSE observation and analysis with our self-developed instrument showed that a coronagraph needs to be designed carefully to achieve its scientific purpose. We gained valuable experience for future follow-up NASA-KASI joint missions: the Balloon-borne Investigation of the Temperature and Speed of Electrons in the Corona (BITSE) and the COronal Diagnostic EXperiment (CODEX).