• Title/Summary/Keyword: Poisonous

Search Result 216, Processing Time 0.02 seconds

Study on the Chemical Management - 2. Comparison of Classification and Health Index of Chemicals Regulated by the Ministry of Environment and the Ministry of the Employment and Labor (화학물질 관리 연구-2. 환경부와 고용노동부의 관리 화학물질의 구분, 노출기준 및 독성 지표 등의 특성 비교)

  • Kim, Sunju;Yoon, Chungsik;Ham, Seunghon;Park, Jihoon;Kim, Songha;Kim, Yuna;Lee, Jieun;Lee, Sangah;Park, Donguk;Lee, Kwonseob;Ha, Kwonchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.58-71
    • /
    • 2015
  • Objectives: The aims of this study were to investigate the classification system of chemical substances in the Occupational Safety and Health Act(OSHA) and Chemical Substances Control Act(CSCA) and to compare several health indices (i.e., Time Weighted Average (TWA), Lethal Dose ($LD_{50}$), and Lethal Concentration ($LC_{50}$) of chemical substances by categories in each law. Methods: The chemicals regulated by each law were classified by the specific categories provided in the respective law; seven categories for OSHA (chemicals with OELs, chemicals prohibited from manufacturing, etc., chemicals requiring approval, chemicals kept below permissible limits, chemicals requiring workplace monitoring, chemicals requiring special management, and chemicals requiring special heath diagnosis) and five categories from the CSCA(poisonous substances, permitted substances, restricted substances, prohibited substances, and substances requiring preparation for accidents). Information on physicochemical properties, health indices including CMR characteristics, $LD_{50}$ and $LD_{50}$ were searched from the homepages of the Korean Occupational and Safety Agency and the National Institute of Environmental Research, etc. Statistical analysis was conducted for comparison between TWA and health index for each category. Results: The number of chemicals based on CAS numbers was different from the numbers of series of chemicals listed in each law because of repeat listings due to different names (e.g., glycol monoethylether vs. 2-ethoxy ethanol) and grouping of different chemicals under the same serial number(i.e., five different benzidine-related chemicals were categorized under one serial number(06-4-13) as prohibited substances under the CSCA). A total of 722 chemicals and 995 chemicals were listed at the OSHA and its sub-regulations and CSCA and its sub-regulations, respectively. Among these, 36.8% based on OSHA chemicals and 26.7% based on CSCA chemicals were regulated simultaneously through both laws. The correlation coefficients between TWA and $LC_{50}$ and between TWA and $LD_{50}$, were 0.641 and 0.506, respectively. The geometric mean values of TWA calculated by each category in both laws have no tendency according to category. The patterns of cumulative graph for TWA, $LD_{50}$, $LC_{50}$ were similar to the chemicals regulated by OHSA and CCSA, but their median values were lower for CCSA regulated chemicals than OSHA regulated chemicals. The GM of carcinogenic chemicals under the OSHA was significantly lower than non-CMR chemicals($2.21mg/m^3$ vs $5.69mg/m^3$, p=0.006), while there was no significant difference in CSCA chemicals($0.85mg/m^3$ vs $1.04mg/m^3$, p=0.448). $LC_{50}$ showed no significant difference between carcinogens, mutagens, reproductive toxic chemicals and non-CMR chemicals in both laws' regulated chemicals, while there was a difference between carcinogens and non-CMR chemicals in $LD_{50}$ of the CSCA. Conclusions: This study found that there was no specific tendency or significant difference in health indicessuch TWA, $LD_{50}$ and $LC_{50}$ in subcategories of chemicals as classified by the Ministry of Labor and Employment and the Ministry of Environment. Considering the background and the purpose of each law, collaboration for harmonization in chemical categorizing and regulation is necessary.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

A Survey on the Workplace Environment and Personal Protective Equipment of Poultry Farmers (양계 농업인의 작업장 환경 및 개인보호구 착용 실태조사)

  • Kim, Insoo;Kim, Kyung-Ran;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Sungwoo
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.454-468
    • /
    • 2014
  • Objectives: This study was conducted to investigate the actual condition of the farm work environment and personal protective equipment as part of the effort to improve livestock work for the safety and health of poultry farmers and provide basic data for establishing plans to improve and develop personal protective equipment. Methods: For this purpose, a questionnaire survey on general information about stables, the poultry work environment, accidents, the wearing of work clothes and personal protective equipment, and the level of awareness related to personal protective equipment was conducted among 148 poultry farmers. Results: As a result, it was found that poultry workplace environment was exposed to such risks as fine dusts; organic dusts; poisonous gases; odorous substances; chicken excrement; contact with chickens, bacteria or viruses; and accidents related to machine operation. Thirteen percent of respondents suffered severe respiratory diseases, and the most frequently injured sites due to accidents were the hands (25.7%), knees (23.8%), arms (17.3%), and head (10.9%). The most frequent type of accident was collisions between the body and obstacles or machinery during movement (36.4%), followed by erroneous machine operation such as feeders and electric shocks (8.5%). Regarding the wearing of work clothes and personal protective equipment, 51.7% of the respondents wore worn-out clothing or everyday clothes, whereas only 32.0% wore work clothes. The percentage of farmers who wore proper protective equipment for the work environment during poultry work was 48.4%. The most frequently used type of protective equipment was boots (38.9%), followed by mask (36.7%), gloves (36.3%), appropriate work clothes (22.6%), quarantine clothes (17.6%), helmets (13.4%), and goggles (12.6%). The rate of wearing goggles was low because they were considered inconvenient and lowered work efficiency. Furthermore, they purchased everyday products available on the market for their personal protective equipment which were not appropriate for maintaining safety in an actual harmful environment and its consequent risks. As a result of the survey of the awareness level related to personal protective equipment, their levels of awareness of accidents and attitude proved to be average or higher, but the practice of wearing protective equipment and the level of knowledge and management of personal protective equipment were lower. Conclusion: This survey found that the wearing status of personal protective equipment among poultry farmers was insufficient even though they were exposed to risks. Most respondents were aware of the necessity of wearing personal protective equipment and of the potential for accidents, but they did not wear proper protective equipment. Their wearing rate was low due to a lack of knowledge about protective equipment, as well as the inconvenience of wearing it. Therefore there is a need to improve and develop specialized personal protective equipment for respiration, hands, and eyes, as well as work clothes that can protect farmers from major harmful matter that is generated in the poultry workplace. Based on the results of this investigation, we will conduct further studies on the required performance and design directions of personal protective equipment while collecting more objective data through field-oriented assessments.

The Structural Characteristics of the Active Ingredients in Several 'Hot and Warm' Herbal Medicine (한약(韓藥)의 온열성약(溫熱性藥)의 성분(成分)과 화학적(化學的) 특성(特性)에 관(關)한 연구(硏究))

  • Shin, Joon-Shik;Ahn, Duk-Kyun;Park, Ho-Koon
    • The Journal of Korean Medicine
    • /
    • v.20 no.1 s.37
    • /
    • pp.1-10
    • /
    • 1999
  • 한약(韓藥)의 효능(效能)은 약성(藥性)에 의해 분류(分類)되고 질병(疾病)을 치료(治療)하며 예방(豫防)하는 작용(作用)을 한다. 그러나 약성(藥性) 이론(理論)의 문헌(文獻)과 임상연구(臨床硏究)는 비교적 많지만 상대적으로 실험연구(實驗硏究)는 일부분에 불과하여 효능(效能)을 입증(立證)하는데 어려움이 많다. 이에 저자(著者)는 온열성약(溫熱性藥)들이 지니고 있는 유효(有效) 성분(成分)들을 조사(調査)하고 이 온열성약(溫熱性藥)에 함유(含有)되어 있는 유효(有效) 성분(成分)들의 구조적(構造的)인 특성(特性)과 화학적(化學的)인 공통점(共通點)을 찾아 온열성약(溫熱性藥)의 분류(分類)에 대한 일반적(一般的)인 기준(基準)을 제시(提示)하고자 하였다. 그 결과 각각의 열성약(熱性藥)과 온성약(溫性藥)들이 함유(含有)하고 있는 유효(有效) 성분(成分)간의 구조적(構造的)인 공통점(共通點)을 찾아내었으며 구조적(構造的)인 공통점(共通點)으로부터 다음과 같은 결론(結論)을 얻었다. 1. 열성약(熱性藥) 중에서 강(强)한 독성(毒性)을 나타내는 부자(附子)와 초오(草烏)의 효능을 나타내는 유효 성분(成分)들은 C19-diterpenoid alkaloid과 C20-diterpenoid alkaloid 계열의 구조(構造)를 지닌 화합물들로 구성(構成)되어 있다. 이 디테르펜 알카로이드(diterpene alkaloid)들의 경우 고리의 구조(構造)가 aconitane(1), hetisan(16)과 7,20-cycloveatchane(17)의 기본골격(基本骨格)을 지니고 있으며, 이 두 가지 기본구조(基本構造)의 공통점(共通點)은 A 고리에 질소를 포함한 2-azabicyclo-[3.3.1]-nonanyl의 부분구조를 갖고 있으며, 이 부분 구조는 자연계에 존재하는 tropane alkaloid들의 기본구조(基本構造)와 유사하다. Tropane alkaloid들은 중추신경계에 작용하는 약물들로 알려져 있으며, tropane alkaloid는 일반적으로 anatoxin a(171)와 같이 강(强)한 독성(毒性)을 나타내며, 부자(附子)와 초오(草烏)가 지니고 있는 강한 독성(毒性)은 바로 2-azabicyclo-[3.3.1]-nonanyl 구조(構造)에 기인하는 것으로 추정할 수 있다. 2. 육계(肉桂)에 주성분으로 함유(含有)되어 있는 cinncassiol(47) 화합물(化合物)들은 분자 내에 bicyclo-[4.3.0]-nonanyl과 bicyclo-[3.3.0]-octanyl의 기본 혹은 부분 구조를 지니고 있다. 3. Cinncassiol(47) 화합물(化合物)들은 강(强)한 항균력(抗菌力)을 보이고 있는데, cinncassiol(47) 화합물들이 지니고 있는 구조적인 특성인 bicyclo-[4.3.0]-nonanyl과 bicyclo-[3.3.0]-octanyl의 기본 혹은 부분 고리구조는 sesquiterpenoid 화합물(化合物)들과 diterpenoid 화합물(化合物)들 중에서 많이 발견되며, 이러한 구조(構造)를 지니고 있는 sesquiterpenoid 화합물(化合物)과 diterpenoid 화합물(化合物)들도 좋은 항균력(抗菌力)을 보이고 있다. 이러한 공통(共通)된 구조상(構造上)의 유사점(類似點)이 항균력(抗菌力)을 나타내는 지표로서 활용 가능성이 기대된다. 4. 온성약(溫性藥)의 경우, 백지(白芷)의 coumarin(39) 화합물(化合物)들과 furocoumarin(61) 화합물(化合物)들, 건량(乾量)의 gingerol(87), shogaol(93), gingerdiol(95) 등과 capsaicin(102), 마황(麻黃)의 ephedrine(124) 계렬(系列) 화합물(化合物)들, 세신(細辛)의 methyleugenol(136)과 asaricin(137)의 구조(構造)에서 발견(發見)할 수 있는 공통적(共通的)인 요소는 phenolic 또는 methoxyphenyl의 공통구조를 지니고 있다. 온성약(溫性藥)의 유효성분들은 공통적으로 phenolic aromatic 화합물(化合物)을 함유(含有)하고 있다. 따라서, 열성약(熱性藥)과 온성약(溫性藥)은 주성분(主成分)들의 분포(分布)가 각기 다르며, 독성(毒性)을 나타내는 열성약(熱性藥)은 2-azabicyclo-[3.3.1]-nonanyl 구조(構造)를 지니고 있고, 육계(肉桂)와 같은 항균력(抗菌力)을 지니는 약물(藥物)은 bicyclo-[3.3.0]-octanyl 또는 bicyclo-[4.3.0]-nonanyl의 구조(構造)를 지닌다. 백지(白芷), 마황(麻黃), 세신(細辛) 등에서 볼 수 있듯이 온성약(溫性藥)은 benzene 구조(構造)를 함유(含有)하는 phenolic aromatic 화합물(化合物)들이 주종을 이룬다.

  • PDF

A Study on the Legislative Conception of Terror of the Advanced European Nations (유럽 선진국의 법제적 테러 개념에 관한 고찰)

  • Kwon, Jeong-Hun;Kim, Tae-Hwan
    • Korean Security Journal
    • /
    • no.15
    • /
    • pp.29-50
    • /
    • 2008
  • Many countries throughout the world have enacted laws on terrorism in the light of the changes that time has brought to them, geographical features, cultural values, and environmental elements. Especially some advanced European nations prescribe the definition of terrorism, the purpose of terrorism, the behavior of terrorism, and the types of crimes related to terrorism and so on for the following reason that it is more vital for the authorities concerned to investigate and punish terrorists after the rise of terrorism. In this regard, this paper analyzes legislative countermoves against terrorists of advanced countries such as France, Germany, and England and through this sheds light on the need of future anti-terrorism bills. The legislative basic guidelines directly to manipulate future terrors based on theories derived from this study could be summarized as follows. In the first place, providing laws on direct investigative power and harsher punishment to those involved in terrorism is a prerequisite for social security and thus the presidential directive of the state anti-terrorism action guidelines just deals with administrative measures without any effective response to terrorism. Hence it is urgent to make anti-terrorism bill concerning investigation and punishment of terrorists. In the second place, it is associated with the objectives of terror. The expression "all sorts of" stated in Korean law is so quite unclear that it can not fulfill the required conditions for naming it "crime". Comprehending provisoes of the crime that meets the purpose of the terrorists is necessary in order to investigate and inflict punishment on them. Therefore, it is advisable to establish specific and precise principles such as political, social, ideological, and religious purpose of terrorists in the bill. In the third place, to meet the flow of times of technicalization, informatization, such provisoes as destruction of electronic data system, crimes related to nuclear materials, purchases of weapons by terrorists, tax administration for prohibition of sale, and arson should be considered in terror bill. In the fourth place, nonselective attack toward unspecified individuals has become a serious issue in our society. Terrorists leave poisonous foods or beverages to crowded place or dump toxic chemicals into river intentionally. Therefore more strict regulations must be included in terror bill to prevent possible terrorist attacks.

  • PDF

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.