• 제목/요약/키워드: Point of inflection

검색결과 213건 처리시간 0.031초

Rheological Measurement of Fiber Spinnability of PVA Solution Dopes in DMSO

  • Chae, Dong-Wook
    • 한국염색가공학회지
    • /
    • 제22권3호
    • /
    • pp.187-193
    • /
    • 2010
  • The effects of molecular weight (MW) and concentration on the rheological properties of poly(vinyl alcohol) (PVA) solutions in dimethyl sulfoxide (DMSO) were investigated at $30^{\circ}C$. Ubbelohde viscometer and rotational rheometer were employed for dilute and concentrated regime, respectively. In the dilute regime, the Mark-Houwink exponent ($\alpha$) of the solutions determined from three different MWs proved 0.73. The critical concentration (C*), in which the entanglement and overlap of polymer molecules began to take place, decreased with increasing the MW of PVA. Huggins constant ($K_H$) values ranged from 0.33 to 0.45 over the MW examined. In the log-log plot of $\eta_{sp}$ versus [$\eta$]C, the PVA with higher degree of polymerization (DP) gave a greater slope exhibiting the inflection point in the vicinity of C*. In the dynamic viscosity ($\eta'$) curve, the PVA solutions of DP 1700 presented Newtonian fluid behavior over most of the frequency range examined. However, the lower Newtonian flow region reduced with increasing the DP. As the PVA concentration increased, $\eta'$ was increased and the onset shear rate for pseudoplasticity was decreased. In the Cole-Cole plot, PVA solutions showed almost a single master curve in a slope of ca. 1.65 regardless of the DP. However, the increase of the concentration from 8 to 12 wt% for PVA solutions of DP 5000 decreased the slope from 1.73 to 1.57. In the tan $\delta$ curve, the onset frequency for sol-gel transition was shifted from 154 to 92 rad/s with increasing the DP from 3300 to 5000 and from 192 to 46 rad/s with increasing the concentration from 8 to 12 wt%. In addition, longer relaxation time ($\lambda$) was observed with increasing the DP and concentration.

하천형 호수인 팔당호의 인 수지 (Phosphorus Budget of a River Reservoir, Paldang)

  • 공동수
    • 한국물환경학회지
    • /
    • 제34권3호
    • /
    • pp.270-284
    • /
    • 2018
  • Paldang is a river reservoir located in the Midwest of Korea, with a water volume of $244{\cdot}10^6m^3$ and a water surface area of $36.5km^2$. It has eutrophied since the construction of a dam at the end of 1973, and the phosphorus concentration has decreased since 2001. Average hydraulic residence time of the Paldang reservoir is about 10 days during the spring season and 5.6 days as an annual level. The hydraulics and water quality of the reservoir can differ greatly, both temporally and spatially. For the spring period (March to May) in 2001 ~ 2017, the reservoir mean total phosphorus concentration calculated from the budget model based on a plug-flow system (PF) and a continuous stirred-tank reaction system (CSTR) was 13 % higher and 10 % lower than the observed concentration, respectively. A composite flow system (CF) was devised by assuming that the transition zone was plug flow, and that the lacustrine zone was completely mixed. The mean concentration calculated from the model based on CF was not skewed from the observed concentration, and showed just 6 % error. The retention coefficient of the phosphorus derived from the CF was 0.30, which was less than those of the natural lakes abroad or river reservoirs in Korea. The apparent settling velocity of total phosphorus was estimated to be $93m\;yr^{-1}$, which was 6 ~ 9 times higher than those of foreign natural lakes. Assuming CF, the critical load line for the total phosphorus concentration showed a hyperbolic relation to the hydraulic load in the Paldang reservoir. This is different from the previously known straight critical load line. The trophic state of the Paldang reservoir has recently been estimated to be mesotrophic based on the critical-load curve of the phosphorus budget model developed in this study. Although there is no theoretical error in the newly developed budget model, it is necessary to verify the validity of the portion below the inflection point of the critical-load curve afterwards.

자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가 (Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss)

  • 이세연;박상호;김우석;이지광;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.

CG산업에서 Simulation 표현의 기술적 활용에 대한 연구 - 불의 표현 활용사례를 중심으로 - (A Study on Simulation Effect Technique of C.G : Focusing on the Fire Simulation Effect)

  • 김용관
    • 만화애니메이션 연구
    • /
    • 통권17호
    • /
    • pp.188-204
    • /
    • 2009
  • 본 연구는 3차원 컴퓨터 그래픽 제작 산업분야에서 최근 가장 경쟁력 있는 분야로 대두되고 있는 연구/개발(R&D) 분야에서 "불의 표현을 중심으로 국내 관련업체들의 기술적 한계를 제시하고 해외 및 국내 애니메이션 제작에서 성공한 기술적 R&D의 과정과 그 결과를 통해 이러한 기술적 한계를 어떻게 극복해야 하는지에 대한 해답을 제시함으로써 과도기를 거쳐 제2의 도약기를 준비하는 국내 컴퓨터 그래픽 애니메이션 산업의 부흥에 도움이 되고자하는 목적으로 연구를 진행하고 있다. 흔히 CT와 IT의 상호 보완적인 특징을 활용한다면 이러한 문제 해결을 넘어 기술적 우위를 확보할 수 있다. 우리는 특히 컴퓨터 그래픽 제작 과정 중 물, 불, 바람, 구름 등의 Simulation System분야와 수십만 캐릭터의 집단행동 또는 단체행동 System 활용도를 중심으로 연구를 진행하였다. 그 중에서 본 논문은 불의 표현에 중점을 두고 실제 작업에 활용된 데이터를 기준으로 그 해답을 제시하였으며 기존의 국내에서 사용하던 전통적 활용방법과 각 연구단체에서 활발하게 진행 중인 프로젝트를 소개하고 본 연구의 적용과정과 결과를 소개함으로써 현업 종사자들에게 향 후 R&D 분야의 나아갈 방향을 제시하고자한다. 창조적인 부재에 너무 집착한 나머지 기술적인 연구 개발부분에의 소홀함이 향 후 미국이나 일본과의 더 큰 기술적 문제로 대두될 수 있음을 명심하고 지금부터라도 과감하고 결단력 있는 기술력의 연구 개발이 필요한 시점이다.

  • PDF

Experimental and numerical investigation of closure time during artificial ground freezing with vertical flow

  • Jin, Hyunwoo;Go, Gyu-Hyun;Ryu, Byung Hyun;Lee, Jangguen
    • Geomechanics and Engineering
    • /
    • 제27권5호
    • /
    • pp.433-445
    • /
    • 2021
  • Artificial ground freezing (AGF) is a commonly used geotechnical support technique that can be applied in any soil type and has low environmental impact. Experimental and numerical investigations have been conducted to optimize AGF for application in diverse scenarios. Precise simulation of groundwater flow is crucial to improving the reliability these investigations' results. Previous experimental research has mostly considered horizontal seepage flow, which does not allow accurate calculation of the groundwater flow velocity due to spatial variation of the piezometric head. This study adopted vertical seepage flow-which can maintain a constant cross-sectional area-to eliminate the limitations of using horizontal seepage flow. The closure time is a measure of the time taken for an impermeable layer to begin to form, this being the time for a frozen soil-ice wall to start forming adjacent to the freeze pipes; this is of great importance to applied AGF. This study reports verification of the reliability of our experimental apparatus and measurement system using only water, because temperature data could be measured while freezing was observed visually. Subsequent experimental AFG tests with saturated sandy soil were also performed. From the experimental results, a method of estimating closure time is proposed using the inflection point in the thermal conductivity difference between pore water and pore ice. It is expected that this estimation method will be highly applicable in the field. A further parametric study assessed factors influencing the closure time using a two-dimensional coupled thermo-hydraulic numerical analysis model that can simulate the AGF of saturated sandy soil considering groundwater flow. It shows that the closure time is affected by factors such as hydraulic gradient, unfrozen permeability, particle thermal conductivity, and freezing temperature. Among these factors, changes in the unfrozen permeability and particle thermal conductivity have less effect on the formation of frozen soil-ice walls when the freezing temperature is sufficiently low.

벽면 근처에 놓인 정방형주의 수직 분할판에 의한 유동 제어 (The Flow Control by a Vertical Splitter Plate for a Square Prism near a Wall)

  • 노기덕;조지룡;오세경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.94-100
    • /
    • 2012
  • 본 연구는 벽면 근처에 놓인 정방형주의 모서리에 수직 분할판을 부착하여 유체력 제어 효과를 양항력 측정실험 및 PIV에 의한 가시화 실험으로 조사한 것이다. 분할판의 폭은 정방형주 폭의 10% 로 했다. 실험변수로서는 수직 분할판의 부착 위치 및 벽면과 사각주 사이의 간격으로 하였다. 정방형주 중심에서 후류방향으로 3.0B(B: 정방형주 한 변 길이) 떨어진 곳에서 와도의 변화가 가장 명확했다. 수직 분할판의 위치 및 유무와 관계없이 간격비 0.4~0.6에서 평균양력계수 및 Strouhal 수의 변곡점이 나타났다. 정방형주 윗면의 뒷 모서리에 수직 분할판을 설치한 경우 항력이 감소하였으며 각 간격비 평균 5.0%의 항력 저감 효과를 얻었다. 정방형주 윗면 박리영역의 크기는 앞쪽 모서리에 수직 분할판을 설치한 경우가 가장 컸고, 원형의 정방형주, 뒷쪽 모서리에 수직 분할판을 설치한 순서로 작았으며, 평균항력계수는 이 박리영역의 크기에 비례했다.

급속 OUR 모니터링을 이용한 Microbial Respiration (MR) 영향인자 평가 (Factors Affecting Microbial Respiration (MR) by Rapid Oxygen Uptake Rate (OUR) Monitoring)

  • 박세용;모경;김연권;김문일
    • 대한환경공학회지
    • /
    • 제33권9호
    • /
    • pp.630-635
    • /
    • 2011
  • 본 연구는 급속 OUR (Oxygen Uptake Rate)방법의 영향인자 평가로서 최적의 미생물 활성도에 미치는 영향인자를 평가하는 실험을 진행하였으며, 실폐수를 이용하여 OUR변화에 따른 SCOD의 변화를 비교 평가하였다. 그 결과 최적의 F/M비는 0.03~0.05이었고, pH는 6.0~8.5, 온도는 $20{\sim}30^{\circ}C$에서 OUR 값이 가장 높았으며, 질산화에 대한 산소소모는 미비했다. OUR 변화에 따른 SCOD (Soluble COD)의 변화는 OUR 변곡점 시간 전후로 SCOD의 분해속도에 차이가 있음을 알 수 있었다. 본 연구의 실험방법을 이용하여 하수처리장의 유입수 실시간 예측을 통해 최적의 운영을 할 수 있을 것이라 기대한다.

골조-전단벽 구조에서 상부 전단벽 미배치의 구조효과 (Structural Effect on Curtailment of Upper Shear Wall in Frame-Shear Wall Structure)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.18-25
    • /
    • 2016
  • 본 연구는 MIDAS-Gen을 사용하여 골조-전단벽 구조에서 상부 전단벽의 미배치에 대한 구조적인 효과를 검토하였다. 본 연구에서는 해석 변수로 상부 전단벽의 미배치 층수, 상하 기둥 단면 치수의 변화, 상하 전단벽 두께 치수의 변화를 설정하였다. 골조-전단벽 구조에서 상부 전단벽의 미배치에 대한 구조적인 효과를 검토하기 위하여 전단벽의 미배치에 따른 전단력/전도모멘트 분포, 전단벽의 변곡점, 수평강성에 대하여 비교분석하였다. 본 연구의 결과는 골조-전단벽 구조에서 상부 전단벽의 미배치가 수평강성과 같은 구조성능에 미치는 영향을 정량적으로 제시하였다. 더욱이 본 연구의 결과는 합리적인 골조-전단벽 구조를 위한 구조설계 자료를 제공하는데 도움이 된다고 확인하였다.

병렬전단벽의 강도와 강성이 커플링보의 설계내력에 미치는 영향 (Design Strength of Coupled Shear Wall System according to Variation of Strength and Stiffness of Coupled Shear Wall)

  • 윤태호;김진상
    • 한국산학기술학회논문지
    • /
    • 제17권10호
    • /
    • pp.743-750
    • /
    • 2016
  • 본 연구에서는 초고층건물의 횡력저항 구조형식으로 널리 사용되는 병렬전단벽-커플링보 구조시스템에서 전단벽의 강도, 강성이 커플링보의 설계 강도에 미치는 영향을 분석하였다. 커플링보에 발생하는 설계내력은 코어벽체의 두께와 콘크리트의 강도가 변하더라도 층별 설계내력은 유사한 경향을 보이고 있으며, 벽체 콘크리트 강도와 두께에 따라 커플링보에 발생하는 외력은 다소 감소하는 경향이 있다. 커플링보의 설계내력은 6개 모델 전부 40층 건물에서, 10층에서 15층의 범위에서 가장 높게 발생하고 있음을 알 수 있다. 즉, 병렬전단벽의 휨변형 변곡점이 형성되는 건물높이의 0.25H~0.375H 위치에서 최대 부재력이 발생한다. 벽체두께가 증가 할수록 코어내부의 커플링보의 발생 외력은 점차 증가하는 것으로 확인되었다. 또한 벽체 두께가 두꺼워질수록 벽체의 콘크리트 강도 증가에 따른 커플링보의 부재력 변화는 적게 나타나는데, 이는 벽체 두께가 두꺼우므로 콘크리트 강도변화의 영향이 적게 미치는 것으로 분석된다. 병렬전단벽의 두께증가는 콘크리트의 강도증가보다 강성변화에 큰 영향을 미치고, 이에 따라 커플링보의 부재력 변화에도 더 큰 영향을 미치는 것으로 분석된다.

단일형 현장타설말뚝의 소성힌지를 고려한 최적설계법 제안 (Analysis of Plastic Hinge of Pile-Bent Structure with Varying Pile Diameters)

  • 안상용;정상섬;김재영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.349-356
    • /
    • 2010
  • In this study, a new design method of pile bent structure considering plastic hinge was proposed on the basis of the beam-column model. Based on the analysis results, it is found that the positioning of plastic hinge on the pile bent structure was influenced by nonlinear behavior of material and p-$\Delta$ effect. Moreover, concrete cracking began to occur at the joint section between the pile and column in case of pile bent structure with different cross-sections. The plastic hinge can be developed on the pile bent structure when large displacement was occurred, and pile bent structures can be maintained well only if it is developed on the column part. Therefore, in this study, the optimized cross-section ratio between column and pile was analyzed to induce the plastic hinge at the joint section between the pile and column. Based on this, the optimized diameter ratio of pile and column can be obtained below the inflection point of the bi-linear curve depending on the relations between column-pile diameter ratio($D_c/D_p$) and normalized lateral cracking load ratio($F/F_{Dc=Dp}$). And through this study, it is founded that in-depth limit($L_{As}$=0.4%) normalized by the pile length($L_P$) are proportionally decreased as the pile length($L_P/D_P$) increases up to $L_P/D_P$=17.5, and beyond that in-depth limit converges to a constant value. Finally, it is found that the proposed limit depth by taking into account the minimum concrete-steel ratio would be more economical design of the pile bent structure.

  • PDF