• 제목/요약/키워드: Point light source

검색결과 148건 처리시간 0.037초

경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

COMMOM MODE COMPENSATION IN FIBER OPTIC INTERFEROMETRIC SENSOR WITH LESS COHERENT LIGHT

  • Park, Kyung-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1108-1111
    • /
    • 1990
  • Sorce noise effect in 1.5 Mach-Zehnder (MZ) interferometer is analyzed. It is shown numerically that with fine adjustments to the feedback gain and initial phase biases, the operating point of the interferometer to achives common mode compensation can be made to lie in a region where the measurand sensitivity is greater than it would be in a conventional Mach-Zehnder interferometer even if the source is less coherent.

  • PDF

User Experience를 고려한 자동차 전조등 설계 방안 (The Design Procedure of Automobile Headlamp Considering User Experience)

  • 김정룡;윤상영;민승남;이호상
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.575-584
    • /
    • 2010
  • The aim of study is to suggest the design procedure of automobile headlamp by considering driver's experience in regard of the visibility and glare during nighttime driving. The characteristics of driver were investigated in terms of the drivers' cognitive ability and reaction time, headlamp specification and visibility, light source and glare. And, the degree of visual discomfort was categorized and recognized as a tool to represent the subjective user experience. The UX point of view was stated when the existing results were seemingly lacking of it. The visual comfort and safety of elderly drivers were also discussed by reviewing the studies of ageing regarding the visibility and driving responses. Finally, this study suggested how to reduce the negative effect of nighttime driving due to the height of headlamp, angle of lighting, color spectrum, discomfort glare, source of light by using the UX perspective and methodology.

Mie 산란광법 및 Shadowgraph법을 이용한 다성분 혼합연료의 증발특성연구 (A Study on Evaporative Characteristics of Multi-component Mixed Fuels Using Mie Scattered Light and Shadowgraph Images)

  • 윤준규;명광재;차경옥
    • 대한기계학회논문집B
    • /
    • 제30권7호
    • /
    • pp.682-691
    • /
    • 2006
  • This study was conducted to assess the effect of mixed fuel composition and mass fraction on spray inner structure in evaporating transient spray under the various ambient conditions. Spray structure and spatial distribution of liquid phase concentration are investigated using a thin laser sheet illumination technique on the multi-component mixed fuels. A pulsed Ar+ laser was used as a light source. The experiments were conducted in a constant volume vessel with optical access. Fuel was injected into the vessel with electronically controlled common rail injector. Used fuel contain $i-octane(C_8H_{18}),\;n-dodecane(C_{12}H_{26})$ and $n-hexadecane(C_{16}H_{34})$ that are selected as low-, middle- and high-boiling point fuel, respectively. Experimental conditions are 25Mpa, 42MPa, 72MPa and 112MPa in injection pressure, $5kg/m^3,\;15kg/m^3\;and\;20kg/m^3$ in ambient gas density, 400K, 500K, 600K and 700K in ambient gas temperature, 300K and 368K in fuel temperature, and different fuel mass fraction. Experimental results indicate that the more high-boiling point component, the longer the liquid phase it were closely related to fuel physical properties, but injection pressure had no effect on. And there was a high correlation between the liquid phase length and boiling temperature at 75% distillation point.

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

휘도비 측정을 통한 유도등의 경년변화 연구 (A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance)

  • 정종진
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.181-185
    • /
    • 2019
  • 본 연구에서는 유도등의 광원과 경년변화에 따른 휘도성능을 분석하기 위하여 사무실, 상가, 병원, 공장 등에 설치된 유도등을 발취하여 CCFL, LED광원별 경년변화에 따른 휘도성능을 분석하였다. 이는 유도등과 같은 전기적 특성을 갖는 소방제품은 설치된 곳의 주위온도나 습도, 먼지 등이 그 성능에 변화를 줄 수 있기 때문에 설치장소별로 발취하여 그 특성을 분석하였다. 실험결과, CCFL유도등은 대형, 중형, 소형 모두 '휘도비 2'정도의 값을 나타내었다. 기술기준 규정값이 '휘도비 9이하'인 점을 감안할 때 매우 양호한 값을 나타냈으며, 경년변화에 의한 휘도비 변화도 거의 없음을 확인할 수 있었다. LED유도등은 '휘도비 5'정도의 값을 나타냈으며, 이는 표시면의 빛이 균일하지 못함을 뜻한다. 또한 경년변화에 의한 휘도비 변화는 거의 없으나, 휘도비의 값은 LED유도등보다 크게 나타났다. 이는 시각적인 측면에서는 만족스럽지 못한 결과이다. 이를 개선하기 위해서는 LED광원의 빛 분산이 필요하며 휘도비 관련 규정을 강화할 필요가 있다.

다색 광원에 대한 가우시안 진폭을 갖는 광학계의 결상 특성 (The Image-forming Property of Optical System having Gaussian Amplitude for Polychromatic Source)

  • 박성종;박혜정
    • 한국안광학회지
    • /
    • 제4권2호
    • /
    • pp.33-38
    • /
    • 1999
  • 다색 광원에 대한 가우시안 진폭을 갖는 광학계의 결상 특성을 조사하기 위하여 다색 광원에 대한 결상 광학계의 색도(chromaticity) 변화와 조도(illuminance) 분포를 계산하였다. 본 논문에서 고려된 다색 광원은 색온도 2,856K인 텅스텐 백열 램프(incandescent-tungsten lamp)를 나타내는 A광원, 대낮의 평균 햇빛(daylight)을 나타내는 C광원, 대낮의 평균 햇빛의 파장영역을 자외선 영역까지 확대하여 보강한 $D_{65}$광원이다. 다색 광원들의 종류에 따라 기하학적 상점에서의 색도 값이 다르게 나타났으며, 기존의 균일한 진폭을 갖는 광학계에 비해 색도 변화가 매우 작게 나타났다. 조도 분포는 다색 광원의 종류에 따라 거의 변화가 없었으며, 초점 심도는 기존의 균일한 진폭을 갖는 광학계에 비해 크게 나타났다. 이러한 결과로부터 결상 광학계에 입사하는 광의 진폭 형태를 균일한 진폭에서 가우시안 형태로 변조시켜줌으로써 초점 심도는 크게, 색도 변화는 작게 할 수 있다.

  • PDF

거친 표면 형상측정을 위한 점광원 절대간섭계의 오차해석과 시스템 변수의 보 (Multiple-Point-Diffraction Interferometer : Error Analysis and Calibration)

  • 김병창;김승우
    • 한국광학회지
    • /
    • 제16권4호
    • /
    • pp.361-365
    • /
    • 2005
  • 표면거칠기가 큰 가공면의 표면형상을 비접촉 고속 측정 하기 위해 고안된 점광원 절대간섭계는 점광원의 위치가 시스템 변수로 정의된다. 시스템 오차인 점광원의 위치 오차가 측정 결과에 미치는 영향을 분석하며, 이를 보정하기 위해 CCD 카메라를 이용한 보정법을 제안한다. 제안된 방법을 검증하기 위해 기준면을 측정하여 측정 정밀도의 향상을 확인하며, 이를 거친 표면형상의 특징을 가진 칩모듈 측정에 적용하였다. 측정 결과 기존의 촉침식 측정기와 $50mm{\time}50mm$의 영역에서 $9.8{\mu}m$의 측정 차이를 보임을 확인하였다.

비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성 (Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor)

  • 전화봉;윤정원;김성홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

사출성형 특성을 고려한 2인치 도광판의 광효율 향상에 관한 연구 (A Study on the Improvement of Optical Efficiency for The 2 inch LGP Considering Injection Molding Characteristics)

  • 도영수;황철진;윤경환
    • 소성∙가공
    • /
    • 제17권5호
    • /
    • pp.322-327
    • /
    • 2008
  • LGP is a key component of LCD back light unit because it determines brightness and sharpness of the display image. Usually, it has optical patterns fabricated on the bottom surface. These optical patterns convert point or line sources placed in the side of LGP to plane source at the top surface by changing the propagating direction of the incident light. In the present paper the LiGA-reflow method was applied to fabricate the LGP mold. Furthermore, the optical simulation considering the replication ratio of pattern height was applied to the pattern design. The optical simulation through systematic correction scheme was adopted to find the optimum distribution of pattern density. Finally, the stamper fabricated by this method was installed in the mold and LGP was produced by injection molding. As a result of luminance measurement for the final product, the average luminance and luminance uniformity was measured 3,180 nit and 84%, respectively. Consequently, the mold fabrication method using the LiGA-reflow and optical simulation(CAE) can save the expense and time compared with the existing fabrication methods(laser ablation and chemical etching).