• Title/Summary/Keyword: Point electrode

Search Result 371, Processing Time 0.036 seconds

Influence of the C.T.I of phenolic resin (페놀수지의 C.T.I에 미치는 영향)

  • 이보호;박동화;정인성
    • Electrical & Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.70-77
    • /
    • 1988
  • This paper describes the influence of the electrode materials, moisture content, electrolyte density, temperature, surface state, ion absorbent on the C.T.I of phenolic resin by the I.E,C, 112 method. C.T.I are increased for electrode materials with low hydrogen overvoltage and high soluble point. Increusing moisture content of samples increased by logarithmical on the droplet number to tracking breakdown. Increasing electrolyte temperature region above 70-80(.deg.C) decreased hydrogen over-voltage, following the density changes are decreased by C.T.I=1/aD$^{2}$-bD+C.

  • PDF

Comparison of Electrical Tree Initiation According to Flow Pattern in EHV Power Cable Insulation (초고압 전력 케이블 절연층의 Flow Pattern 방향각에 따른 전기 트리 개시 특성 비교)

  • Lee, Seung-Yoo;Kim, Young-Ho;Cho, Dae-Hee;Lee, In-Ho;Park, Wan-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1532-1534
    • /
    • 1999
  • Electrical treeing phenomenon, regarded as pre-breakdown which accelerates aging process leading an insulation to the complete breakdown, is with no doubt extremely fatal to the performance of the insulation. Investigated in this paper is electrical treeing representing local dielectric failure according to flow pattern, the flow history of liquid polyethylene formed during the extrusion process. Experiments of electrical tree initiation by means of ramp tests were conducted using newly developed electrode system with point-to-point structure. Constant voltage tests were also carried out with the electrode system to estimate the life time of the insulation. Results were analyzed using statistical method such as Weibull distribution.

  • PDF

Reduction characteristics of NOx on point-plane electrode (침대평판전극에서의 NOx 제거특성)

  • Kim, G.H.;Kim, Jong-Dal;Kim, Jung-Dal;Kim, C.W.;Lee, D.C.;Koh, H.S.;Pak, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1317-1319
    • /
    • 1995
  • In this paper, we studied reduction characteristics of NOx gas produced from diesel engine combustion using by point-plane electrode. Here, input voltage forms were types of three [DC, AC, DC Positive pulse] and NOx gas of 1700ppm was composed of NO 1665ppm, $NO_2$ 35ppm on balance of $N_2$. We investigated NOx reduction characteristics as various of parameters, are gas flow rate, input voltage form and, humidity. From the results of study, reduction characteristics of NOx exhibited good when gas flow rate was small, input voltage was DC and much humidity were contained to NOx gas.

  • PDF

Micro Electrochemical Machining Characteristics and Shape Memory Effect in Ni-Ti SMA (Ni-Ti SMA의 미세 전해가공특성과 형상기억효과)

  • 김동환;박규열
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.43-49
    • /
    • 2003
  • In this study, micro electrochemical machining method was introduced for accomplishment the fabrication technology of functional parts and smart structures using the Ni-Ti shape memory alloy. From the experimental result, the micro part which has very fine surface could be achieved by use of micro electrochemical process with point electrode method. Concretely, the optimal performance of micro electrochemical process in Ni-Ti SMA was obtained at the condition of approximately 100% of current efficiency and high frequency pulse current. That is, much finer surface integrity and shape memory effect can be obtained at the same condition mentioned above.

The High Voltage Research of X-ray Detector Based on Amorphous Selenium (a-Se 기반의 X선 검출기에서의 고전장 간섭 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Cho, Sung-Ho;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.853-856
    • /
    • 2002
  • Present. direct method x-ray conversion detector is studied by abroad medical instrument and country with amorphous Selenium. And we search the method for large area x-ray detector. Amorphous-Selenium based photoreceptor is widely used on the X-ray conversion materials. But amorphous-selenium based x-ray conversion detector is broken by high voltage and leakage defect point. In this paper, We investigated top-electrode distance rate to improve defect point and high voltage broken. The result to appoint to made large area x-ray conversion detector with base data.

  • PDF

A Study of Skin Resistance of Jeong-Acupuncture Points Using the Compound Electrode (복합전극을 이용한 정혈의 최대피부저항특성에 관한 연구)

  • 최진욱;최귀원;박영배
    • The Journal of Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.100-109
    • /
    • 2003
  • Objectives : The purpose of this study is to 1. measure the skin resistance of jeong-acupuncture points using compound electrode, and 2. develop a database of skin resistance based on age and gender. Methods : The skin resistance of jeong-acupuncture points on the hands and feet of 191 healthy volunteers was measured using a specially designed compound electrode. A constant current of $5{\mu\textrm{A}}$ was applied to the measurement points and the skin resistance was obtained using amplifier, A/D converter and Acknowledge software program, Results : 1. ANOVA statistical analysis showed no significant differences between jeong-acupuncture points on hands and feet. 2. Paired samples t-test showed no significant differences between Yin-Yang meridian points, 3. When the data were sorted by gender, factor analysis showed statistically significant differences between male and female groups in all measured points except for left foot. 4. Based on the factor analysis, a significant relationship between the skin resistance and age was found in feet. However, no such relationship was found in hands. Conclusions : There are differences in skin resistance according to sex and age, Further clinical research is necessary using compound electrode method.

  • PDF

An Experimental Study on the Implementation and Stabilization of Atmospheric Pressure Glow Discharge (대기압 글로우 방전의 구현 및 안정화에 대한 실험적 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.42-46
    • /
    • 2008
  • Ionizers are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, ultraviolet and glow discharge. Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. In this paper, we did an experimental study to trace the mechanism and stabilization of atmospheric pressure glow discharge using the several size and shape of electrodes. As an experimental result, to sustain conditions of atmospheric pressure glow discharge is that discharge voltage is 360V, discharge current is 12mA, apply frequency is 1kHz between electrodes when positive electrode is molybdenum(Mo) and negative electrode is copper(Cu). We confirmed that the mechanism and stabilization of atmospheric glow discharge is deeply concerned with the shape and material of electrode for discharge. Especially, glow discharge in atmospheric pressure was well generated and sustained according with the physical properties used electrode materials, example melting point, thermal conductivity, and etc.

Ozone Generation Characteristics by Surface-Silent Discharge According to the Length of Coaxial Electrode (동축형 전극길이 변화시의 연면무성방전에 의한 오존발생특성(I))

  • Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su;Lee, Hyeong-Ho;Lee, Sang-Geun;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.791-797
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. In this paper the concentration, yield and generation quantity of the ozone by the Surface-Silent Discharge According to the Length of Coaxial Electrode is described. The electrodes composed of 3 electrodes-2 gaps are coaxial type and the ozone generation tube were designed and fabricated from the point of view of the energy efficiency, stability and easy control. To investigate the ozone generation dependency on electrode length, a few discharge tubes with different lengths were fabricated. The experimental equipments were provided with cooling system and dehumidifier for the many testing conditions. The main results show that the concentration, yield and generation quantity of ozone are improved by decreasing gas temperatures and increasing electrode lengths.

  • PDF

A Study on the Properties and Methods of Electrode System for Tapping of Melts (출탕유도전극을 이용한 용융물의 출탕방법 및 특성에 대한 연구)

  • Moon, Young-Pyo;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.499-503
    • /
    • 2016
  • For safety and economy reasons, hazardous waste including radioactive waste is desired to be converted into stable waste forms with a maximum volume reduction. High temperature melting technology using a plasma torch system can effectively treat even the non-flammable waste as desired. By far, one of the most difficult process for melting the non-flammable waste is a tapping of melts because the melting point of a residual slag in the tapping hole is high and because the viscosity of the melt increases sharply when tapping out. In case of a stationary furnace with a slant tapping port on the side of furnace, a certain amount of melts is left in the tapping hole after tapping out. Because of this, at every end of a melting cycle, the tapping hole needs to be opened by tapping device. The developed tapping device of melts based on both a guide electrode and auxiliary electrode is adequate for the application to discharge of melts except that the consumption of the guide electrode is somewhat faster than expected. Melt is collected in the water cooled vessel.

A Study of the Characteristics on the Vacuum Interrupter with Axial Magnetic Field Type using 3 Dimension Finite Element Analysis (3차원 유한요소해석을 이용한 종자게형 진공 인터럽터의 특성고찰)

  • 하덕용;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.460-467
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density on the vacuum interrupter with axial magnetic field type using 3 dimension finite element analysis. An axial magnetic field parallel to the current flow in the arc column can improve the current breaking capacity of vacuum interrupter by affecting the arc mode. The axial magnetic flux density on the contact electrode surface is analyzed by inputting external current as a function of the transient time for sine half wave. And it also is analyzed within the gap distance of the contact electrode. The peak value of current but is decreased with the descending current on the contact electrode surface and within the gap distance of the contact electrode. The residual magnetic field is generated on the contact electrode surface and within the gap distance in the instant of zero current, which is due to the influence of eddy currents. The phase shift due to eddy currents, defined as time difference between the maximum value of current and axial magnetic field, is about 1ms in the center point of gap distance.