Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Dose Distribution of Rectum in the treatment of Uterine Cervical Cancer using Remote Afterloading System (RALS시행시 선원의 거리 이동및 직장선량에 관한 계산치와 측정치의 비교연구)

  • 김성규;신세원;김명세
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.67-74
    • /
    • 1994
  • Dose distribution of point source represents an inverse square law as the distance, Difference of measurement value and calculation value according to moving distance of radiation source show very large error in dose calculation of Brachytherapy. Therefore, in RALS of high dose rate, dose calculation have an important effect in treatment of uterine cervix cancer and recurrent rate. In this paper, authors measured moving distance of radiation source carrying out RALS. And we measured Rectum dose compared with calculationdose.

  • PDF

The Impact of Tissue Inhomogeneity Corrections in the Treatment of Prostate Cancer with Intensity-Modulated Radiation Therapy (전립선암의 세기조절 방사선 치료시 밀도보정의 효과)

  • Han Youngyih;Park Won;Huh Seung Jae
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.149-155
    • /
    • 2004
  • Purpose: To investigate the effects of tissue inhomogeneity corrections on the dose delivered to prostate cancer patients treated with Intensity-Modulated Radiation Therapy (IMRT). Methods and Materials: For five prostate cancer patients, IMRT treatment plans were generated using 6 MV or 10 MV X-rays. In each plan, seven equally spaced ports of photon beams were directed to the isocenter, neglecting the tissue heterogeneity in the body. The dose at the isocenter, mean dose, maximum dose, minimum dose and volume that received more than 95% of the isocenter dose in the planning target volume ( $V_{p>95%}$) were measured. The maximum doses to the rectum and the bladder, and the volumes that received more than 50, 75 and 90% of the prescribed dose were measured. Treatment plans were then recomputed using tissue inhomogeneity correction maintaining the intensity profiles and monitor units of each port. The prescription point dose and other dosimetric parameters were remeasured. Results: The inhomogeneity correction reduced the prescription point dose by an average 4.9 and 4.0% with 6 and 10 MV X-rays, respectively. The average reductions of the $V_{p>95%}$ were 0.8 and 0.9% with the 6 and 10 MV X-rays, respectively. The mean doses in the PTV were reduced by an average of 4.2 and 3.4% with the 6 and 10 MV X-rays, respectively. The irradiated volume parameters in the rectum and bladder were less decreased; less than 2.1 % (1.2%) of the reduction in the rectum (bladder). The average reductions in the mean dose were 1.0 and 0.5% in the rectum and bladder, respectively. Conclusions: Neglect of tissue inhomogeneity in the IMRT treatment of prostate cancer gives rise to a notable overestimation of the dose delivered to the target, whereas the impact of tissue inhomogeneity correction to the surrounding critical organs is less significant.

  • PDF

Dose Computation Modeling for Frustum Typed Ir-192 of Ralstron Source (Ralstron 선원대체형 Ir-192 원추선원의 선량 전산화 모델링)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.19-29
    • /
    • 2001
  • In dose modeling, the shape of actual source and sealed capsule are important parameter to determine the physical dose computation. The author investigated the effect of filter of source self-absorption and sealed capsule to designed the high dose rate Ir-192 source for Ralstron(Japan) unit. The size of source designed to 1.5 mm $\Phi$ x 1.5mm length of actual source sealed with stainless steel which is 3.0mm $\Phi$ x 12.0mm length connected to driving cable. The dose attenuation was derived 66.3 % from 2655 segmented source at reference point of 10mm lateral distance of source. The output dose rate factor in tissue for designed source showed 0.0013511 cGy/mCi-sec in reference point at 1cm lateral distance of source center. The dose distribution at inferior of source showed the 52% of that of source tip region, however, the filtering effect was small as 4% at 45degrees of source axis. The dose attenuation within 20 degrees of source axis at near source-cable connector showed large filtering effect as 40% over, but the small effect was revealed isotropic dose distribution at large angle.

  • PDF

Control of heparinization by activated clotting time during extracorporeal circulation (개심술시 Activated Clotting Time 을 이용한 Heparin 투여 조절에 관한 임상적 고찰)

  • 서충헌
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.281-288
    • /
    • 1983
  • Heparinization is an essential step in extracorporeal circulation for open heart surgery. But wide individual variation to heparin effect sometimes makes it difficult to anticoagulate safely or neutralize appropriately. Because the conventional set protocol of heparinization did not consider this individual variation, a new method of control of heparinization was proposed by Dr. Brian Bull in 1974. We compared the group in which a conventional set protocol was used [Control group] with the other in which a new protocol modified from that of Bull was used [ACT group], on the aspects of the dosages of heparin and protamine administered and postoperative bleeding. Our conventional protocol [Control group] consisted of: 1. Initial heparin was given at dose of 350U/Kg into the right atrium prior to bypass. 2. Additional heparin was given every hour during E.C.C., as much as a half of the Initial dose. 3. 600U of heparin was mixed into every 100ml. of priming solution. 4. The protamine dose was calculated by totalling the units of heparin given to the patient and giving 1 .8mg. of protamine per 100 units of heparin. ACT protocol [ACT group] consisted of: 1. Initial heparinization was same as that of conventional protocol. 2. ACT`s were checked before [A point] and 10 minutes after initial heparinization [B point]. With these 2 points, a dose response curve was drawn. 3. Heparin for the priming solution was same as in control group. 4. Every 30 minutes during E.C.C., ACT`s were checked with Hemochron [International Technidyne Corp.]. ACT between 450 and 600 seconds was regarded as safety zone. If ACT checked at a time was below 450 seconds, heparin dose was calculated on the dose-response curve to lengthen ACT to 480 seconds and was given into the oxygenator. 5. About 10 minutes before the term of E.C.C., ACT was checked to estimate the blood heparin level at the time. Then, protamine dose was calculated at dose of 1.Stag per 100 units of heparin. The calculated dose of protamine was mixed into 50 to lO0ml of 5% Dextrose Water and dripped intravenously during the period of 15 minutes. Compared these two groups mentioned above, results were obtained as follows: 1. Mean value of normal ACT checked with Hemochron on 30 preoperative patients was 124 seconds [range 95-145 sec.]. 2. Doses of heparin and protamine given to the patient were decreased in ACT group as much as 32.2% and 62.2% respectively. 3. Postoperative bleeding and transfusion were also decreased in ACT group in 60.5% and 67.1% respectively. 4. Our modified dose-response curve did not cause any problems in the control of heparinization. 5. Initial heparinization [Heparin 350U/Kg] was sufficient for the most patients until 60 minutes under extracorporeal circulation. 6. We used 1.5mg of protamine to neutralize 100 units of heparin. But smaller dose of protamine may be sufficient for appropriate neutralization.

  • PDF

Bladder And Rectum Dose Define 3D Treatment Planning for Cervix Cancer Brachtherapy Comparison of Dose-Volume Histograms for Organ Contour and Organ Wall Contour (자궁경부암의 고선량률 근접치료시 장기묘사 방법에 따른 직장과 방광의 선량비교 분석)

  • Kim, Jong-Won;Kim, Dae-Hyun;Choi, Joon-Yong;Won, Yeong-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.327-333
    • /
    • 2012
  • Purpose: To analyze the correlation between dose volume histograms(DVH) based on organ outer wall contour and organ wall delineation for bladder and rectum, and to compare the doses to these organs with the absorbed doses at the bladder and rectum. Material and methods: Individual CT based brachytherapy treatment planning was performed in 13 patients with cervical cancer as part of a prospective comparative trial. The external contours and the organ walls were delineated for the bladder and rectum in order to compute the corresponding dose volume histograms. The minimum dose in 0.1 $cm^3$, 1 $cm^3$, 2 $cm^3$, 5 $cm^3$, 10 $cm^3$ volumes receiving the highest dose were compared with the absorbed dose at the rectum and bladder reference point. Results: The bladder and rectal doses derived from organ outer wall contour and computed for volumes of 2 $cm^3$, provided a good estimate for the doses computed for the organ wall contour only. This correspondence was no longer true when large volumes were considered. Conclusion: For clinical applications, when volumes smaller than 5 $cm^2$ are considered, the dose-volume histograms computed from external organ contours for the bladder and rectum can be used instead of dose -volume histograms computed for the organ walls only. External organ contours are indeed easier to obtain. The dose at the ICRU rectum reference point provides a good estimate of the rectal dose computed for volumes smaller than 2 $cm^2$ only for a midline position of the rectum. The ICRU bladder reference point provides a good estimate of the dose computed for the bladder wall only in cases of appropriate balloon position.

A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology - A Point of Tube Voltage and Filtration - (진단방사선 영역에서 피폭선량 감소를 위한 기술적 연구 - 관전압과 부가여과판을 중심으로 -)

  • Ha, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.89-97
    • /
    • 1992
  • X-ray quality is identified numerically by half value layer(H.V.L) and the HVL is affected by the kVp and the amount of filtration in the useful beam. X-ray quality evaluated by H.L.D is influenced by kVp and filtration. Author had several experiments with phantom in diameter of 8 cm normal adult chest, for reduction of radiation dose of the patients in diagnostic radiology and got some results. 1. H.V.L is increased the thicker the filter and the higher the kVp. 2. If the kVp is increased from 60 to 120, the skin dose can be reduced as 34%(Skin dose of 60 kVp with 4 mmAl filter : 100%). 3. If the 4 mmAl filter with 60 kVp is added to x-ray tube, skin dose can be reduced as 23% than no filter. 4. Therefore high kVp and filtration can increase output to input dose ratio and 120 kVp and 4 mmAl filter were most effective for reduction of patient dose in chest radiography.

  • PDF

An innovative idea for developing a new gamma-ray dosimetry system based on optical colorimetry techniques

  • Ioan, Mihail-Razvan
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.519-525
    • /
    • 2018
  • Obtaining knowledge of the absorbed dose up-taken by a certain material when it is exposed to a specific ionizing radiation field is a very important task. Even though there are a plenitude of methods for determining the absorbed dose, each one has its own strong points and also drawbacks. In this article, an innovative idea for the development of a new gamma-ray dosimetry system is proposed. The method described in this article is based on optical colorimetry techniques. A color standard is fixed to the back of a BK-7 glass plate and then placed in a point in space where the absorbed dose needs to be determined. Gamma-ray-induced defects (color centers) in the glass plate start occurring, leading to a degree of saturation of the standard color, which is proportional, on a certain interval, to the absorbed dose. After the exposure, a high-quality digital image of the sample is taken, which is then processed (MATLAB), and its equivalent $I_{RGB}$ intensity value is determined. After a prior corroboration between various well-known absorbed dose values and their corresponding $I_{RGB}$ values, a calibration function is obtained. By using this calibration function, an "unknown" up-taken dose value can be determined.