• 제목/요약/키워드: Point defect

Search Result 494, Processing Time 0.029 seconds

The Cu-CMP's features regarding the additional volume of oxidizer to W-Slurry (W-slurry의 산화제 첨가량에 따른 Cu-CMP특성)

  • Lee, Woo-Sun;Choi, Gwon-Woo;Seo, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.370-373
    • /
    • 2003
  • As the integrated circuit device shrinks to the smaller dimension, the chemical mechanical polishing (CMP) process was required for the global planarization of inter-metal dielectric(IMD) layer with free-defect. However, as the IMD layer gets thinner, micro-scratches are becoming as major defects. Chemical-Mechanical Planarization(CMP) of conductors is a key process in Damascene patterning of advanced interconnect structure. The effect of alternative commerical slurries pads, and post-CMP cleaning alternatives are discuess, with removal rate, scratch dentisty, surface roughness, dishing, erosion and particulate density used as performance metrics. Electroplated copper depostion is a mature process from a historical point of view, but a very young process from a CMP persperspective. While copper electrodepostion has been used and stuidied for dacades, its application to Cu damascene wafer processing is only now ganing complete accptance in the semiconductor industry. The polishing mechanism of Cu CMP process has been reported as the repeated process of passive layer formation by oxidizer and abrasion action by slurry abrasives. however it is important to understand the effect of oxidizer on copper pasivation layer in order to obtain higher removal rate and non-uniformity during Cu-CMP process. In this paper, we investigated the effects of oxidizer on Cu-CMP process regarding the additional volume of oxidizer.

  • PDF

Transjugular occlusion of patent ductus arteriosus using an Amplatz canine ductal occluder in a Cocker spaniel dog

  • Choi, Ran;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • A 5-year-old female Cocker spaniel dog (body weight 7.0 kg) was presented with primary complaints of exercise intolerance and loud precordial thrill which was noticed since she was a puppy. Physical examination revealed a grade V/VI continuous murmur over the maximal point of the left basal area, bounding femoral pulse, but no differential cyanosis. Tall R waves were detected in electrocardiogram, suggesting left ventricular enlargement. Diagnostic imaging studies showed enlarged left ventricle, bulged descending aorta (dAo), markedly dilated right pulmonary artery, and continuous shunt flow between the dAo and main pulmonary artery. Based on these findings, the dog was diagnosed as left to right shunted patent ductus arteriosus (PDA). The patent ductus arteriosus was treated by lodging a PDA duct occluder via the transvenous approach. Clinical signs were markedly improved after the ductal occlusion, the shunt flow was mildly persistent. The case presented is the first case of PDA occluded by the PDA duct occluder via the transvenous approach in a small breed of dog. Although the residual shunt flow was mildly persisted, the dog was clinically normal without detectable murmurs.

Revascularization of Popliteal Artery Injury in Trauma Around Knee Joint (슬관절주위 외상에 의한 슬와동맥 손상의 재혈관화)

  • Han, Soo-Hong;Shin, Dong-Eun;Dan, Jin-Myung;Kim, Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • Popliteal artery injury in blunt trauma of knee joint is not common but poses high rate of amputation due to anatomical characteristics or delayed diagnosis and treatment. The aim of the present study is to review the authors' experiences with this condition and identify factors contributing to disability. We reviewed 7 cases of popliteal artery injury in trauma around knee. Injury mechanism, type of vessel damage, associated injuries, mangled extremity severity scores (MESS), ischemic time and additional treatments were analyzed. Tibial fracture, distal femoral fracture and serious soft tissue defect were combined. Mean MESS was 9.9 point and mean time of revascularization was 7.1 hours. Transfemoral amputation was performed in 2 cases due to vascular insufficiency and devastating infection, and 4 patients were able to walk without any support at the last follow up. Age, the severity of soft tissue injury, ischemic time and MESS are thought to be related to prognosis, and young patients with short ischemic time show best results, but authors experienced one exceptional case. We have to consider multiple factors related to the prognosis in popliteal artery injury with fractures around knee, and careful decision is needed regarding to early amputation.

  • PDF

Dynamic Parameters Identification of an Air Spring for Vibration Isolation of a Complex Testing System of COG Bonding Process (COG 본딩공정 고속복합 검사 시스템의 방진용 에어 스프링의 동적 파라미터 규명 연구)

  • Lee, Ju-Hong;Kim, Pil-Kee;Seok, Jong-Won;Oh, Byung-Joon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.13-20
    • /
    • 2010
  • Due to the recent quantum leaps forward in bio-, nano-, and information-technologies, the precisionization and miniaturization of mechanical and electrical components are in high demand. The allowable margin for vibration limits for such equipments is becoming stricter. In order to meet this demand, understandings on the characteristics of vibration isolation systems are highly required. Among the components comprising the vibration isolation system, air spring has become a focal point. In order to develop a complex defect tester for COG bonding of display panels, a vibration isolation system composed of air springs for mounting is considered in this study. The dynamic characteristics of the air spring are investigated, which is the most essential ingredient for reducing the vibration problem of the tester to the lowest level. Uncoupled dynamic parameters of the air spring are identified through MTS experiments, followed by suggestion of a model-based approach to obtain the remaining coupled dynamic parameters. Finally, the dynamic behaviors of the air spring are estimated and discussed.

Optical Properties of $CdAl_2S_4 : Co_{2+}$ Single Crystal ($CdAl_2S_4 : Co_{2+}$ 단결정의 광학적 특성)

  • Kim, Hyung-Gon;Kim, Nam-Oh;Son, Kyeong-Choon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.382-387
    • /
    • 2000
  • The $CdAl_2S_4 and CdAl_2S_4 : Co^{2+}$ single crystals were grown by the chemical transport reaction method using iodine as a transport agent. The $CdAl_2S_4 and CdAl_2S_4 : Co^{2+}$single crystals were crystallized into a defect chalcopyrite structure. The optical energy gap of the $CdAl_2S_4 and CdAl_2S_4 : Co^{2+}$ single crystals was found to be 3.377 eV and 2.924 eV, respectively, at 300 K. Blue emission with peaks in 456nm~466nm at 280K was observed in the $CdAl_2S_4$ single crystal. Optical absorption and emission peaks due to impurities in the $CdAl_2S_4 Co^{2+}$ single crystal were observed and described as originating from the electron transition between energy levels of the $Co^{2+} ion sited at the Td symmetry point.

  • PDF

The Design of an Extended Complex Event Model based on Event Correlation using Aspect Oriented Programming

  • Kum, Deuk-Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.10
    • /
    • pp.109-119
    • /
    • 2017
  • In recent through development of IOT owing to that mass stream data is being generated in variety of application complex event processing technology is being watched with keen interest as a technology to analyze this kind of real-time continuous data. However, the existing study related with complex event processing only comes to an end at simple event processing based on low-level event or comes to an end at service defect discovery with providing limited operator and so on. Accordingly, there would be limitation to provide useful analysis information. In this paper in consideration of complex event along with aspect-oriented programming an extended complex event model is provided, which is possible to provide more valuable and useful information. Specifically, we extend the model to support hierarchical event structures and let the model recognize point-cuts of aspect-oriented programming as events. We provide the event operators designed to specify the events on instances and handle temporal relations of the instances. It is presented that syntax and semantics of constructs in our event processing language including various and progressive event operators, complex event pattern, etc. In addition, an event context mechanism is proposed to analyze more delicate events. Finally, through application studies application possibility of this study would be shown and merits of this event model would be present through comparison with other event model.

Development of a Reliable Real-time 3D Reconstruction System for Tiny Defects on Steel Surfaces (금속 표면 미세 결함에 대한 신뢰성 있는 실시간 3차원 형상 추출 시스템 개발)

  • Jang, Yu Jin;Lee, Joo Seob
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1061-1066
    • /
    • 2013
  • In the steel industry, the detection of tiny defects including its 3D characteristics on steel surfaces is very important from the point of view of quality control. A multi-spectral photometric stereo method is an attractive scheme because the shape of the defect can be obtained based on the images which are acquired at the same time by using a multi-channel camera. Moreover, the calculation time required for this scheme can be greatly reduced for real-time application with the aid of a GPU (Graphic Processing Unit). Although a more reliable shape reconstruction of defects can be possible when the numbers of available images are increased, it is not an easy task to construct a camera system which has more than 3 channels in the visible light range. In this paper, a new 6-channel camera system, which can distinguish the vertical/horizontal linearly polarized lights of RGB light sources, was developed by adopting two 3-CCD cameras and two polarized lenses based on the fact that the polarized light is preserved on the steel surface. The photometric stereo scheme with 6 images was accelerated by using a GPU, and the performance of the proposed system was validated through experiments.

A Propagation Prediction Model for Planning a Cell in the PCS System (PCS 시스템 셀설계를 위한 전파예측 모델)

  • 김송민
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.103-112
    • /
    • 1998
  • This paper proposes a propagation prediction model which can calculate a propagation path loss easily at option point in case of the propagation processing by repeat reflection when we analysis a propagation route, it makes the calculation speed which is the defect of a geometrical of image method and a ray-launching method improve and we develop and apply the algorithms which can do an angle of incidence, an angle of reflection with a propagation direct path, a reflection path and a maximum reflection number arithmetic process synchronously. Finally we choose as a sample which is the real road condition where is around SK telecoms chunnam branch office in wolgok-dong, kwangsan-ku, kwangju and simulate proposition model then we demonstrate the relative superiority with comparing the results.

  • PDF

Treatment Using a Single-Lobed Rotation Flap in Diabetic Forefoot Ulceration: Five Case Reports (단일엽 회전 피판술을 이용한 당뇨병성 전족부 궤양의 치료: 5예 보고)

  • Kim, Jun-Beom;Lee, Bong-Ju;Kim, Cheol-U;Jung, Deukhee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.208-211
    • /
    • 2019
  • Diabetic foot ulcers can progress to the point where amputation is needed, and so these ulcers require active treatment. Skin grafts or flaps can be performed for coverage of this type of ulcer. Local flap surgery is relatively easy to perform and good results have been previously reported. We performed single-lobed rotation flap on 5 cases of forefoot ulcer around the site of weight bearing. The location of the foot ulcers was the medial part of the first metatarsophalangeal joint in all the patients. The mean size of the defect was 4.70 ㎠. Managing of ulcers, controlling of diabetes and infection, and improving of peripheral blood flow were performed before surgery. In two cases, infection progressed to the articular cartilage and so metatarsophalangeal joint fusions were performed simultaneously. All the cases were completely transplanted. There was no recurrence of the ulcers, and all the patients were able to walk.

A SOUND SPECTROGRAPHICAL STUDY ON THE KOREAN VOWELS AND CONSONANTS PRONOUNCED BY OPENBITE PATIENTS - Frequency Analysis - (SOUND SPECTROGRAPH를 이용한 개교환자의 한국어 자${\cdot}$모음의 발성에 관한 연구 - 주파수 분석을 중심으로 -)

  • Kim, Ki-Dal;Yang, Won Sik
    • The korean journal of orthodontics
    • /
    • v.15 no.1
    • /
    • pp.55-66
    • /
    • 1985
  • The study was undertaken to ascertain the speech defect of patients with malocclusion, especially of openbite patients, by means of the spectral analysis method. The experimental group was composed of ten female openbite patients and their mean age was 13.8 yrs. The control group was also composed of ten female girls and their mean age was 13.7 yrs. As for the speech material, eight Korean monophthrongs and two Korean fricatives and two affricatives were used. Speeches were recorded and then analyzed by a Kay 7800 digital sonagraph. Formant frequency level or range was used as a phonemic parameter. The results were as follows: 1. Among Vowels /a:/ : $F_1,\;F_3\;and\;F_1/F_2$ showed abnormality. /o:/ and $/w:/:F_2,\;F_2-F_1\;and\;F_1/F_2$ showed abnormality. 2. Among Consonants /S/ and /h/ : The upper and lower borders of the frequency range showed abnormality. (equation omitted) : The lower border of the frequency range showed abnormality. $/C^{h}/$ : The upper and lower borders of the frequency range and concentration point showed abnormality.

  • PDF