• Title/Summary/Keyword: Point Spread Function

Search Result 155, Processing Time 0.037 seconds

Clinical Microscopy: Performance, Maintenance and Laser Safety (임상에서의 현미경: 작동, 유지보수 및 레이저 안전)

  • Lee, Tae Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • A microscope is the fundamental research and diagnostic apparatus for clinical investigation of signaling transduction, morphological changes and physiological tracking of cells and intact tissues from patients in the biomedical laboratory science. Proper use, care and maintenance of microscope with comprehensive understanding in mechanism are fully requested for reliable image data and accurate interpretation for diagnosis in the clinical laboratory. The standard operating procedure (SOP) for light microscopes includes performance procedure, brief information of all mechanical parts of microscopes with systematic troubleshooting mechanism depending on the laboratory capacity. Maintenance program encompasses cleaning objective, ocular lenses and inner optics; replacement and calibration of light source; XY sample stage management; point spread function (PSF) measurement for confocal laser scanning microscope (CLSM); quality control (QC) program in fluorescent microscopy; and systematic troubleshooting. Laser safety is one of the concern for medical technologists engaged in CLSM laboratory. Laser safety guideline based on the laser classification and risk level, and advisory lab wear for CLSM users are also expatiated in this overview. Since acquired image data presents a wide range of information at the moment of acquisition, well-maintained microscopes with proper microscopic maintenance program are impulsive for its interpretation and diagnosis in the clinical laboratory.

Detection Probabilities of the X-ray Point Sources in X-ray Extended Sources

  • Kim, Min-Sun;Kim, Eun-Hyeuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.33.2-33.2
    • /
    • 2010
  • Galaxy clusters are known to be very bright in X-ray and contain a large number of X-ray point sources within the X-ray emission. However, due to the fluctuations of the X-ray emission, it is very difficult to detect faint X-ray sources and to extract accurately the photometric properties of the X-ray point sources in galaxy clusters. In addition, the most X-ray telescopes show spatially varying point spread function (PSF) and suffer from severe vignetting. The Chandra Archival Survey of Galaxy Clusters project is a wide-area ($\sim40deg^2$) survey of serendipitous Chandra X-ray sources in galaxy cluster fields, containing ~58,000 X-ray point sources in ~800 Chandra ACIS observations of ~600 galaxy clusters. This project aim to investigate the density environmental effects on the physical properties of the X-ray point sources, comparing physical properties of the X-ray point sources in galaxy clusters to those in typical fields. To utilize the sensitivity and detection probability of the X-ray point sources in galaxy clusters, we perform extensive Monte-Carlo simulations. In this poster, we compare the detection probability of the X-ray point sources in galaxy clusters to that of typical fields, and discuss quantitatively the difference between them.

  • PDF

초고속 자기 공명 영상 기법 - Echo Planar 영상 및 Spiral Scan 영상

  • 안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.6-12
    • /
    • 1999
  • Echo Planar Imaging (EPI) Spiral Scan 영상을 초고속 자기공명영상 기법으로서 전체 k-space의 데이터를 한번 scan에 다 받을 수 있기 때문에 데이터 측정시간을 100ms 이내로 단축시킬 수 있다. 이러한 초고속 영상 기법은 최근 활발히 연구되고 있는 뇌기능 영상과 관련하여 중요도가 더욱 커지고 있다. EPI는 직각좌표계에서 데이터를 받기 때문에 재구성은 비교적 쉬우나 eddy current를 많이 야기시키는 단점을 가지고 있다. 반면에 Spiral Scan 영상은 먼저 데이터를 원 또는 직각좌표계로 interpolation을 한 후 재구성하여야 하는 단점이 있으나, 상대적으로 eddy current가 작고, 방향과 무관하게 균일한 point spread function을 가지며, 혈류와 관련한 위상이 스스로 rephasing 되어 심장 영상 등에 유리한 장점이 있다.

  • PDF

Study on Modified Triangular Interferometer (변형 삼각간섭계에 대한 고찰)

  • Kim, Soo-Gil;Ko, Myung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.264-265
    • /
    • 2003
  • 3차원 영상정보처리에 이용되는 변형 삼각간섭계는 인코히어런트 광을 이용한 3차원 영상정보의 기록과 복원에 이용되고 있다. 최근에는 3차원 영상의 기록과 재생이외의 분야, 예를 들면 3차원 물체의 결함 검출 및 현미경분야에 대한 활용 연구도 진행되고 있다. 본 연구에서는 이러한 분야에 응용이 되고 있는 변형 삼각간섭계의 개선과 이에 대한 일반적인 전달함수와 PSF(point-spread function)를 제시하였으며, 변형 삼각간섭계에 대한 복소흘로그램 생성과 수치적 복원영상결과도 제시하였다.

  • PDF

A Logistic Regression for Random Noise Removal in Image Deblurring (영상 디블러링에서의 임의 잡음 제거를 위한 로지스틱 회귀)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.10
    • /
    • pp.1671-1677
    • /
    • 2017
  • In this paper, we propose a machine learning method for random noise removal in image deblurring. The proposed method uses a logistic regression to select reliable data to use them, and, at the same time, to exclude data, which seem to be corrupted by random noise, in the deblurring process. The proposed method uses commonly available images as training data. Simulation results show an improved performance of the proposed method, as compared with the median filtering based reliable data selection method.

Multiple objects focusing based on image segmentation using radius of PSF (점확산함수 반지름을 사용한 영상분할 기반 다중객체 자동초점)

  • 김기만;황성현;신정호;백준기
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.7-10
    • /
    • 2003
  • This paper proposes the multiple objects focusing algorithm. Given multiple objects at different distances from a camera, we assume that one object is well-focused and the others are out-of-focused. The proposed auto-focusing algorithm is summarized as follows: (i) detects edges from an input image, (ⅱ) estimates the radius of PSF (Point Spread Function) across the edge, (ⅲ) gather edge points having same radius of PSF, (ⅳ) segments the image into regions with the same radius of PSF, and (ⅴ) restores the each segmented region using the corresponding PSF.

  • PDF

디지털 자동초점 시스템을 위한 초점 불완전 열화 추정과 복원 기법

  • 김상구;백준기
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.139-143
    • /
    • 1997
  • 본 논문에서는 점확산함수(point spread function; PSF)의 추정을 기반으로 한 완전한 자동초점 시스템을 제안한다. 초점이 맞지 않은 영상의 정확한 PSF의 추정을 위해서, 입력 영상을 부영상으로 분할하고, 에지를 가진 부영상들의 계수함수 응답의 평균을 취한다. 초점이 맞지 않은 열화로 발생하는 PSF는 보통 영상이 물체와 배경간에 선형의 경계를 가지고 있다는 가정하에 에지의 방향을 따라 평균되어진 계단함수 응답의 차이를 따라 추정되어진다. 이렇게 예측된 PSF를 사용하여 영상복원 필터는 제한적 최소 제곱의 접근방법을 통해 구현되어진다.

  • PDF

New Approach on Modified Triangular Interferometer (변형 삼각간섭계에 대한 새로운 접근방법)

  • 김수길
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.265-267
    • /
    • 2003
  • 3차원 영상정보처리에 이용되는 변형 삼각간섭계는 인코히어런트 광을 이용한 3차원 영상정보의 기록과 복원에 이용되고 있다. 최근에는 3차원 영상의 기록과 재생이외의 분야, 예를 들면 3차원 물체의 결함검출 및 현미경분야에 대한 활용 연구도 진행되고 있다. 본 연구에서는 이러한 분야에 응용이 되고 있는 변형 삼각간섭계의 시스템개선과 시스템에 대한 전달함수와 PSF(point-spread function)의 일반화를 시도하였으며, 변형 삼각간섭계에 대한 복소홀로그램 생성과 수치적 복원영상결과도 제시하였다.

  • PDF

Blind Deconvolution for Microwave Scanning Imaging Radiometer

  • Park, Hyuk;Kim, Sung-Hyun;Choi, Jun-Ho;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.673-675
    • /
    • 2003
  • The image restoration algorithm for microwave imaging radiometer is proposed. A blind deconvolution method was proposed. A point spread function was identified and three deconvolution schemes were employed, Wiener filtering, Lucy- Richardson deconvolution, and Maximum Likelihood blind deconvolution. The experimental data is illustrated with restored image.

  • PDF

Effect of Phase Error on the Lateral Resolution of Reconstruction Image in Incoherent Triangular Holography (인코히어런트 삼각 홀로그래피에서 위상오차가 횡축방향의 해상도에 미치는 영향에 관한 연구)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.1-6
    • /
    • 2013
  • It is introduced the phase error sources of a incoherent hologram in incoherent triangular holography and derived the reconstruction image of point-source including the phase error in the lateral direction. From the reconstruction image of point-source, we analyzed the effect of phase error on the lateral resolution. When the phase retardation errors and azimuth angle error of a wave plate and a polarizer range from 0 to $2{\pi}/15$, the normalized intensities of reconstructed images are down by about 0.1% and 2.3%, respectively.