• Title/Summary/Keyword: Point Heating System

Search Result 193, Processing Time 0.028 seconds

Influences of Structural Features on Electrical Properties and Heating Characteristics of Al-Ta Alloy Thin Films (Al-Ta 합금박막의 구조적 인자가 전기적 특성 및 발열 특성에 미치는 영향)

  • Song Daegwon;Lee Jongwon;Park In Yong;Kim Kyujin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.4 s.33
    • /
    • pp.23-27
    • /
    • 2004
  • The $Al_xTa_{1-x} (x=0.0{\~}1.0)$ alloy thin films were deposited by RF-magnetron sputtering system, and the crystal quality, surface morphology, and electrical properties were examined using XRD, AFM, 4-point probe techniques in this study. The thin films were grown according to the alloy compositions first, and the effects of film thickness and mask patterns were investigated afterwards. Also, the heating characteristics were examined by heat controller. The obtained results showed that the high electrical resistivity was obtained for Al content $x=6.63at\%$, and the even higher resistivity was accomplished for the samples with smaller thickness and narrower width. The heating temperature demonstrated the identical trend to the electrical properties, and the highest heating temperature ($400^{\circ}C$) and output power ($12.6W/cm^2$) were obtained for the sample with Al content $x=6.63\%$, film thickness d=500 nm, film width w=1.5 mm.

  • PDF

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season (겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구)

  • Lee, Ki Yong;Kim, Kee Han;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.110-114
    • /
    • 2016
  • Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

A Study on High Frequency Induction Hardening of S45C Specimen by FEA and Experiment (유한요소해석 및 실험에 의한 S45C 시편의 고주파 유도경화에 관한 연구)

  • Park, Kwan-Seok;Choi, Jin-kyu;Lee, Seok-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.1-7
    • /
    • 2018
  • In this study, we proposed a high frequency induction hardening analysis method based on electromagnetic-thermal co-simulation. In the high frequency induction heating analysis, the results of the finite element analysis (FEA) (considering the change of the material property and the cooling factor according to the temperature) and those of the high frequency induction hardening experiment (using the S45C specimen) were compared. The hardness of the S45C specimens was measured using the micro Vickers hardness test to determine the depth of hardening. The measurement results were then compared with the results of FEA. The result of high frequency induction heating analysis showed that the temperature was more than $750^{\circ}C$, which is the A2 transformation point of S45C, while the temperature during quenching was below $200^{\circ}C$. The results showed that the difference of the depth of hardening between the FEA and the experiment is 0.2mm.

A Case Study on Economic Analysis of a Solar Water Heating System and a Ground Source Heat Pump System Applied to a Military Building (군 복지시설의 지열시스템과 태양열시스템 경제성 평가 사례 연구)

  • Lee, Jong-Chan;Park, Young-Ho;Lee, Ghang;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • This study is to analyze the performance of SWH(Solar Water Heating) and GSHP(Ground Source Heat Pump) systems by evaluating their energy efficiency and LCC(Life Cycle Cost) as being applied to the OO hall as a selected building in the Army. The OO hall, used as bathrooms, dining rooms, accommodations and offices, has reinforced concrete structure system with three floors above the ground and one underground, and its total floor area is approximately 2,917$m^2$. Two energy simulations are conducted to predict the yearly cooling and heating energy of the selected building: One is for analysis of an air-conditioning energy consumption using the e-Quest program, and another is for two new-renewable energy facilities as a water heating source using the RETScreen. The installed capacity of two new-renewable energy facilities is determined according to the 5% level of total standard construction cost. As a briefly result, SWH system is more energy-effective than GSHP system. Considering the break-even point, it is expected that SWH can take only 3 years 11 months to pay for itself in savings while the investment of GSHP can be recovered in more than 16 years 6 months.

A Molecular Dynamics Study in a Binary System with Free Surface (자유표면을 가진 이원계의 상전이에 대한 분자동역학 연구)

  • Han, Hye-Won;Jang, Hyeon-Gu
    • Korean Journal of Materials Research
    • /
    • v.10 no.8
    • /
    • pp.581-588
    • /
    • 2000
  • Phase transition of the Lennard-Jonesian binary system with a free surface was studied by employing molecular dynamics simulation. The main focus of this study was to investigate the effect of size misfit and solute concentration on phase transition during heating and quenching. For a binary system with a free surface, the melting point and the critical quenching rate decrease as size misfit and solute concentration increase.

  • PDF

A Neuroanatomical and Neurophsiolgical basic Study on the Mechanism of Acupuncture in central nervous system (침자기전(鍼刺機轉)의 중추신경계(中樞神經系)에서의 신경해부(神經解剖).생리학적(生理學的) 기초연구(基礎硏究))

  • Kim, Jeong-Heon
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.514-550
    • /
    • 1996
  • There are many theory in acupuncture mechanism, so we must know the detail contents. and then we can use the acupuncture as we know. the follow article will be helpful in this part. 1. Spinal cord are role in intermediate part in somatosensorypathway also in acupuncture stumulating tract 2. Acute pain pathway started in laminae I, V of gray colmn, next are the spinothalamic tract(trigeminal spinothalamic tract in above neck part) and then go to the specific thalamic nucleus. but chronic pain in laminae II, III, VI, VII, next are spinoreticular tract(trigeminal spinoreticular tract in the neck part) and finally to the nonspecific thalamic nucleus. 3. Thalamus is very important area in somatosensory stimuation including acupuncture stumulating sensory also as a pain control center. but except this, there are Hypothalamus, Limbic system Cerebral cortex and Cerebellum as intermediator. as we Know hypothalamus is related to the emotional analgesic system with a limbic system. 4. A ${\delta$ fiber has relationship in Acute, sharp and initial pain, contrary this C fiber is related with Chronic, dull and last pain. 5. In Acupuncture mechanism of pain analgesia, there are two theory, one is gate control theory as large fiber another is stimuation produced analgesia as small diameter fier. 6. In DNIC, the stimulation sources are mechanical, thermal, heating, pain and acupuncture stimulation etc. we call these as a Heterotopic Noxious Stimulation. 7. In DNIC, SRD(Subnucleus reticularis dorsalis)is core nucleus in pain imtermediated analgesic mechanism. 8. Takeshige insisted nonacupuncture point dependent analgesic mechanism and acupuncture point dependent analgesic mechanism. and protested that Stimulation acupuncture piing evoke blocking nomacupuncture point analgesic pathway.

  • PDF

Film Boiling Heat Transfer Characteristics in Liquid-Liquid System (액체,액체계의 막비등열전달 특성)

  • 김병주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • Film boiling heat transfer characteristics in liquid-liquid systems are studied experimentally. Liquid gallium as a heating liquid, n-pentane, freon-113, and ethanol are used as boiling liquids. In gallium-n-pentane and gallium-freon-113 systems the minimum film boiling point occurred at higher temperature than those observed in copper-boiling liquid systems. However MFB point occurred almost at the same temperature for the case of ethanol. This difference are due to the effects of contact angle and interfacial agitations in gallium-boiling liquid systems. Film boiling heat transfer rate, for the gallium-boiling liquid systems considered in this work, found to be approximately 10% higher than those in copper-boiling liquid systems, whose main cause is believed to be gallium-boiling liquid interfacial agitations affected by the density ratio between gallium and boiling liquid.

Application of ICP(Iterative Closest Point) Algorithm for Optimized Registration of Object Surface and Unfolding Surface in Ship-Hull Plate Forming (선박 외판 성형에서 목적 형상과 전개 평판의 최적 정합을 위한 ICP(Iterative Closest Point) 알고리즘 적용)

  • Lee, Jang-Hyun;Yoon, Jong-Sung;Ryu, Cheol-Ho;Lee, Hwang-Beom
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.2
    • /
    • pp.129-136
    • /
    • 2009
  • Generally, curved surfaces of ship hull are deformed by flame bending (line heating), multi-press forming, and die-less forming method. The forming methods generate the required in-plane/bending strain or displacement on the flat plate to make the curved surface. Multi-press forming imposes the forced displacements on the flat plate by controlling the position of each pressing points based upon the shape difference between the unfolded flat plate and the curved object shape. The flat plate has been obtained from the unfolding system that is independent of the ship CAD. Apparently, the curved surface and the unfolded-flat surface are expressed by different coordinate systems. Therefore, one of the issues is to find a registration of the unfolded surface and the curved shape for the purpose of minimum amount of forming works by comparing the two surfaces. This paper presents an efficient algorithm to get an optimized registration of two different surfaces in the multi-press forming of ship hull plate forming. The algorithm is based upon the ICP (Iterative Closest Point) algorithm. The algorithm consists of two iterative procedures including a transformation matrix and the closest points to minimize the distance between the unfolded surface and curved surfaces. Thereby the algorithm allows the minimized forming works in ship-hull forming.

Drying Characteristics of Large Western Redcedar Timber During Radio Frequency/Vacuum Drying (웨스턴 레드시더 큰 정각재(正角材)의 고주파 진공 건조 특성)

  • Jung, Hee-Suk;Avramidis, Stavros;Cai, Liping
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.1-8
    • /
    • 1998
  • Western redcedar timber, 26 by 26cm in cross section and by 200cm long, was dried in a laboratory radio-frequency/vacuum kiln under 65torr of ambient pressure and a fixed frequency of 6.78MHz for the potential rapidly dry large timber. All process data were collected and saved in a computer through a data acquisition system. The temperature in the middle of timber was higher than temperature at the quarter point of timber length and thickness. Temperature gradients developed in the longitudinal and transverse direction of timber. The pressure in the middle of timber was higher than pressure at the quarter point of timber length. The pressure in the middle of timber was lower in the early stage of drying, and higher in the latter stage of drying than pressure at the quarter point of timber thickness. Power density was very highest during heating period and then gradually decreased. The drying curve was approximately linear and the total drying time was 27 hours from an initial moisture content(MC) of 48.6 percent to a final Me of 19.2 percent with only a few mild internal checks in the middle location of timber.

  • PDF

Design of Low-Melting Metal Fuse Elements of Current Sensing Type Protection Device for Large Capacity Secondary Battery Protection System (대용량 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 저융점 금속 가용체 설계)

  • Kim, Eun Min;Kang, Chang yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.427-432
    • /
    • 2018
  • High-capacity secondary batteries can cause explosion hazards owing to microcurrent variations or current surges that occur in short circuits. Consequently, complete safety cannot be achieved with general protection that is limited to a mere current fuse. Hence, in the case of secondary batteries, it is necessary for the protector to limit the inrush current in a short circuit, and to detect the current during microcurrent variations. To serve this purpose, a fuse can be employed for the secondary battery protection circuit with current detection. This study aims at designing a protection device that can stably operate in the hazardous circumstances associated with high-capacity secondary batteries. To achieve the said objective, a detecting fuse was designed from an alloy of low melting point elements for securing stability in abnormal current states. Experimental results show that the operating I-T and V-T characteristic constraints can be satisfied by employing the proposed current detecting self-contained low melting point fuse, and through the resistance of the heating resistor. These results thus verify that the proposed protection device can prevent the hazards of short circuit current surges and microcurrent variations of secondary batteries.