• 제목/요약/키워드: Point Heating System

검색결과 193건 처리시간 0.022초

온돌에 대한 역사적 고찰 (A Historical Study of Ondol)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제17권2호
    • /
    • pp.49-56
    • /
    • 1979
  • In Korean housing designs reflect uniqueness as a result of the influence of regional and atmospheric factors. In this regard, the early use of the hot floor (ondol) system is of special significance. This system is still in use today, not only for house-heating purposes in the homes of commoners, but also for cooking in the kitchen. The present study represents an investigation of the ondol structure since its earliest known usage. Methodology involves a documentary examination of the system. In point of time, this begins with the system's earliest usage and proceeds chronnologically down to the end of the Yi Dynasty. Research indicates that something very much like the ondol system appeared in the early tribal society of Mahan and its usage continued in the state of Koguryo (during the Three Kingdoms Period) in the homes of the poor. This unique system which had its origin in cold northern areas was utilized on a much broader basis during the Koryo Dynasty. Coming down to the Yi Dynasty it found acceptance and application in all parts of the peninsula. Variations in major component parts of the structure, such as the fuel hole, the flue, the draft , and the chimney, normally reflect regional dissimilarities. It is perhaps most significant that here-in contrast to other devices we have a system that serves concurrently for both heating and cooking purposes.

  • PDF

직렬 열교환기의 열전달에 관한 연구 (A Study on the Heat Transfer of In-line Heat Exchanger)

  • 최순열;김민수
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.48-53
    • /
    • 2008
  • Heat exchangers are commonly used in practice in a wide range of application, from heating and air-conditioning system in a household, to chemical processing and power production in a large plant. Heat transfer in a heat exchanger usually involves convection in each fluid and conduction through the wall separating the two fluids. The heat transfer characteristics of tube banks of in-line arrangements of four circular cylinders in a cross flow are compared for a range of tube locations and Reynolds numbers. The in-line pitch ratio was set up in the range of $1.5\leq L/d\leq4.0$, where L is the center to center distance and d the circular cylinder diameter, and in the Reynolds number of $13,000\leq Re\leq50,000$. The local and mean Nusselt numbers were estimated, and then. Subsequently, the heat transfer characteristics of four circular cylinders were found to exhibit a strong dependency upon the cylinder spacing and separation point of their upstream cylinders.

  • PDF

폐용제 회수용 이중관형 열교환기 특성 해석 (Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery)

  • 구재현;이재근
    • 자원리싸이클링
    • /
    • 제9권3호
    • /
    • pp.13-21
    • /
    • 2000
  • 본 연구는 폐용제를 가열, 증발 및 음축과정을 거쳐 용제를 회수하는 시스템의 열교환기 해석에 관한 것으로, 고온 열매체유로 가열되는 이중관형 열교환기를 사용하여 용제 증발과정의 열전달 특성을 분석하고 용제유량과 가열온도에 따라 물, 벤젠 및 알칼벤젠의 증발을 위해 요구되는 전열면적을 분석하였다. 폐용제 회수장치는 용제 공급펌프 이중관형 열교환기, 진공 스프레이 챕버 및 응축기동으로 구성되며, 이중관형 열교환기는 용제액을 열적 포화온도를 가열시키는 구간과 포화된 용제액을 증발시키는 구간으로 구성된다. 관 내 용제의 증발을 위한 전열면적을 열평형 모델링에 의해 예측하였고, 이중관형 열교화기의 관 내 온도분포 측정을 통해 이론값과 비교 분석하였다. 용제유량 0.1~0.51l/mm 및 가열온도 130~$260^{\circ}C$의 범위에서 용제유향 증가 및 가열온도 감속에 따라 단위전열면적당 열전달양이 감소하기 때문에 용제 증발을 위한 전열면적은 증가하였다. 관 내 용제 증발을 위한 전열면적의 이론적 분석결과는 측정값과 일치하였으며, 이중관형 열교환기를 사용한 폐용제의 증발과정을 통해 용제를 회수하는 기술에 적용이 가능하다.

  • PDF

열펌프와 잠열축열을 이용한 온실 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Energy Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump and Latent Heat Storage)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제26권6호
    • /
    • pp.553-562
    • /
    • 2001
  • The greenhouse heating system with heat pump and latent heat storage was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air, soil surface and cover film in the greenhouse were developed and its validity was justified by actual data. From the analysis of experimentally measured and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the greenhouse with a heat pump and a latent heat storage system were very much close to the experimental values at the error range of 1.0$\^{C}$. 2. The expected values of soil surface temperature fur the geenhouse with a heat pump and a latent heat storage system were very much close to the experimental values at the error range of 1.0$\^{C}$. 3. The expected values of thermal energy flow fur the greenhouse with a heat pump and a latent heat storage system were very much close to the experimental values at the error range of 167.2kJ/m$^2$h. 4. Heat lass value of day time was found to be larger than that of night time as much as 1.11 time. 5. At day time. the inside air temperature was shown to be higher than the set point of 7.0$\^{C}$. At night time, the inside air temperature was controlled in order to maintain higher temperatures than the set point.

  • PDF

유리 파단면의 화재감식에 관한 실험적 연구 (An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass)

  • 문용수;공하성
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

정혈 지열감도 측정법의 객관화 -기기 개발 및 시험 측정 결과 보고- (Instrumentation of Thermo-sensitivity Test of Well Points, a Pilot Report)

  • 이병훈;이상훈;김기왕
    • Journal of Acupuncture Research
    • /
    • 제28권2호
    • /
    • pp.133-141
    • /
    • 2011
  • Objectives : Although the thermo-sensitivity test in Well points in 12 Meridians(井穴知熱感度測定法) has been used for several decades, it is still performed by a manual way, and lack in objectivity consequently. To make it more objective, accurate and convenient test, we have developed a novel system to test thermo-sensitivity in Well points. Methods : To enhance the blindness of the test, we made a shielded system which give heat to some fingers of subjects in random way. To perform the test in quantitative manner, we developed a fully automated, computer-controlled system composed of heating bulbs and response button array. Results : The developed system showed linearity in heating the finger phantom. It also gave acceptable but interesting features in pilot tests with several young adult subjects. Conclusions : By the developed system, we could improve objectivity and convenience of the thermo-sensitivity test in Well points.

PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석 (Energy Economic Analysis of Standard Rural House Model with PV System)

  • 이찬규;김우태
    • 한국산학기술학회논문지
    • /
    • 제14권4호
    • /
    • pp.1540-1547
    • /
    • 2013
  • 국가 에너지 소비의 25%를 차지하는 건물에너지의 저감과 귀농인구의 증가에 따른 저에너지 친환경 주택모델의 수요 충족을 위해 EnergyPlus를 사용하여 PV 시스템이 적용된 농어촌 주택 표준모델의 건물에너지요구량을 기반으로 경제성 분석을 하였다. 2가지 타입의 PV 시스템이 적용되었고 발전된 전력을 건물의 냉방기기와 전기기기, 그리고 난방기기에 사용하였다. 계산에 사용된 주택의 연간 건물에너지요구량은 난방이 냉방에 비해 7배 크게 나타났다. Case1과 Case2로 나누어 PV 시스템의 경제성분석을 실시한 결과, Case1은 냉난방 및 전기기기에 발전된 전력을 사용하고 판매하는 것이, Case2는 냉방과 전기기기에만 전력을 사용하고 전량 판매하는 것이 경제적으로 유리한 것으로 판단된다. 하지만, 향후 전력 판매가격과 가스가격이 변동되면 결과는 달라질 수 있다. 초기투자비용은 Case1이 약 13년, Case2는 약 11년이 지나면 회수되는 것으로 나타났다. Case2가 초기설치비용이 비싸지만 회수기간이 지나면 Case1보다 약 3배 더 많은 이익을 얻을 수 있어 수명연한인 25년 이상 사용 시 경제성 측면에서 유리할 것으로 판단된다.

유도가열용 고주파 공진형 인버터를 이용한 과열증기 발생장치 개발에 관한 연구 (A Study on the Development of Superheater Using High-Frequency Resonant Inverter for Induction Heating)

  • 신대철;권혁민;김기환;김용주
    • 전력전자학회논문지
    • /
    • 제9권2호
    • /
    • pp.119-125
    • /
    • 2004
  • 본 논문에서는 간접 유도가열 되는 보일러 시스템과 주파수 범위가 20〔KHz〕에서 50〔KHz〕사이에서 작동되는 전압형 직렬공진 고주파인버터를 이용하여 열 기체를 발생시키는 전압형 공진형 인버터에 관하여 설명하였다. 얇은 스텐레스 판재가 서로 스폿 용접되어 연결되어있고 기포성 적층형 충진발열체로 특수하게 설계된 유도 가열기는 외부에 워크 코일로 감겨져 있는 불소수지계의 절연용기 안에 삽입되어있다. 이 워크 코일은 공진형인버터와 연결되어 있으며 유도가열기를 통해 흐르는 관 유체를 1단가열부에서 저압의 포화증기를 2단가열부에서 열방사성 증발유체를 생성하는 본 시스템의 성능 및 효용성을 실용적인 측면에서 논의하고 평가한다.

선박연료유의 정제처리 및 첨가제 혼합에 따른 물리.화학적 특성 변화에 관한 연구 (A Study on the Variation of Physical & chemical Properties with Refining treatment and Additive mixture for Marine Fuel Oil)

  • 한원희;남정길;이돈출;박정대;강대선
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.291-297
    • /
    • 2006
  • 최근 국제 유가의 상승으로 인한 선박 운용비를 절감하기 위하여 중소형 선박에서도 저질연료유의 사용이 검토되고 있는 추세이다. 이 연구에서는 현재 중소형 선박에서 연료유로 사용중인 경유와 중유 MF380 을 혼합하여 소형선박에 사용이 가능하도록 제조한 혼합연료유인 MF30 연료유에 대하여 그 물리 화학적 특성을 분석하고 정제처리 및 연료유첨가제 효과에 대해 알아보았다. 연구 결과 두가지 전처리 방식인 원심식청정기와 가열 및 균질 방식 (M.C.H) 의 효과는 다소 미약하였지만, 유동점과 인화점은 다소 낮아졌다. 연료유첨가제로 인한 개질 효과는 뚜렷이 나타나지 않았다.

  • PDF

선박연료유의 정제처리 및 첨가제 혼합에 따른 물리.화학적 특성 변화에 관한 연구 (A Study on the Variation of Physical & Chemical Properties with Refining Treatment and Additive Mixture for Marine Fuel Oil)

  • 한원희;남정길;이돈출
    • 해양환경안전학회지
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2007
  • 최근 국제 유가의 상승으로 인한 선박 운용비를 절감하기 위하여 중소형 선박에서도 저질연료유의 사용이 검토되고 있는 추세이다. 이 연구에서는 현재 중소형 선박에서 연료유로 사용중인 경유와 중유MF380을 혼합하여 소형선박에 사용이 가능하도록 제조한 혼합연료유인 MF30 연료유에 대하여 그 물리 화학적 특성을 분석하고 정제처리 및 연료유첨가제 효과에 대해 알아보았다. 연구결과 두 가지 전처리 방식인 원심식청정기와 가열 및 균질 방식(M.C.H)의 효과는 다소 미약하였지만, 유동점과 인화점은 다소 낮아졌다. 연료유첨가제로 인한 개질 효과는 뚜렷이 나타나지 않았다.

  • PDF