• Title/Summary/Keyword: Point Heating System

Search Result 193, Processing Time 0.024 seconds

A Quality Assurance Study for the Application of Cook/chill System in School Foodservice Operation (I) - Broiled Spanish Mackerel - (학교급식에 Cook/chill system 적용을 위한 품질보증연구(I) - 삼치구이 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.278-293
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point-based standardized recipe applicable to cook/chilled Broiled Spanish Mackerel in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. HACCP for the production of menu items was identified in simulation study. At each critical control point, time-temperature profile was recorded and microbiological analysis was done. Also chemical analyses and sensory evaluation were conducted for 5 days of chilled storage. The results of time-temperature measurement of Broiled Spanish Mackerel by each production phase showed satisfactory condition that met the standards. Broiled Spanish Mackerel showed excellent microbiological quality from raw ingredient phase ($TPC:2.58{\pm}0.12\;Log\;CFU/g$) to holding phase ($TPC:2.70{\pm}0.42\;Log\;CFU/g$). Coliform (0.84 Log MPN/g) and fecal coliform (0.84 Log MPN/g) were detected from marinating phase ($TPC:3.82{\pm}0.52\;Log\;CFU/g$). After heating, only few mesophiles were detected ($TPC:1.83{\pm}0.49\;Log\;CFU/g$). No psychrophiles, coliforms and fecal coliforms were detected. In the phases after rapid chilling, during chilled storage and after reheating and distribution, almost none of the above microbes were detected. Salmonella and Listeria monocytogenes were not detected in all production phases. The pH immediately after cooking was 6.65 and then increased significantly to 6.81 on the third day of chilled storage (p<0.001). Acid value did not show significant changes while total volatile based nitrogen (TVBN) dramatitically increased during storage periods (p<0.01). In the result of sensory evaluation, general acceptability points had been rated high in the first day of storage, and then, the points were decreased significantly on the third day (p<0.05). General acceptability points ranged from 8.86 to 10.68. Accordingly, Broiled Spanish Mackerel is highly recommendable cook/chill system. Considering the DHSS standards for storage, the ideal shelf-life recommended for Broiled Spanish Mackerel is within 4 days excluding cooking day. For Broiled Spanish Mackerel, critical control points were purchasing and receiving of frozen Spanish Mackerel, heating, chilling, chilled storage, reheating and distribution.

  • PDF

A Study on the Boiling Heat Transfer of R-113 in a Concentric Annular Tube (환상이중원관에서 R-113의 비등열전달에 관한 연구)

  • Kim, M.H.;Kim, C.H.;Oh, C.;Yoon, S.H.;Kim, K.K.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.12-23
    • /
    • 1994
  • The two-phase flow is observed in power plants, chemical process plants, and refrigeration systems etc., and it is very important to solve the heat transfer mechanism of a boiler, an automic reactor, a condenser and various types of evaporators. Recently, the problem of two phase heat transfer is braught up in many regions with development of energy saving technique. In flow boiling system it is necessary to store data in each condition because the heat transfer characteristics of flow boiling region vary by the change of flow pattern and the magnetude of heat flux to tube length, and be subtly affected by the flow and heating condition. So basic study for knowing flow pattern in heat transfer region and the relation between heat transfer characteristic and flow condition is desired to accumulate data in wide variety of liquid and flow system in the study of heat transfer of two phase flow. In this study R-113 was selected as working fluid whose properties were programmed by least square method, and experiment was conducted in the region of mass flow $1.628{\times}10^6$~$4.884{\times}10^6$/kg/$m^2$hr with inlet subcooling 10~3$0^{\circ}C$, sustaining test section inlet pressure to 1.5kg$_f$/$cm^2$abs.

  • PDF

Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort (차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Baek, Je-Hyun;Kim, Kyung-Chun;Ji, Ho-Seong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers (배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석)

  • An, Jung-Sik;Choi, Sun-Ho;Bang, Jeong-Ju;Jung, Joong-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

Numerical Investigation on the Urea Melting Characteristics with Coolant and Electric Heaters (냉각수 및 전기 가열 방식에 따른 요소수 해동 특성에 관한 수치해석 연구)

  • Lee, Seung Yeop;Kim, Man Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • A Urea-SCR(Selective Catalytic Reactor) system, which converts nitrogen oxides into nitrogen and water in the presence of a reducing agent, creates a major exhaust gas aftertreatment system for NOx reduction among other compounds. With regard to vehicle applications, a urea solution was chosen based on its eutectic composition of a 32.5wt% urea-water solution. An important advantage of this eutectic composition is that its melting point of $-11.7^{\circ}C$ is sufficiently low to avoid solidification in cold environments. However, the storage tanks must be heated separately in case of low ambient temperature levels to ensure a sufficient amount of liquid is available during scheduled start ups. In this study, therefore, a numerical investigation of three-dimensional unsteady heating problems analyzed to understand the melting processes and heat transfer characteristics including liquid volume fraction, temperature distributions, and temperature profiles. The investigations were performed using Fluent 6.3 commercial software that modeled coolant and electric heater models based on a urea solution. It is shown that the melting performance with the electric heater is higher than a coolant heater and is more efficient.

Performance of steel beams at elevated temperatures under the effect of axial restraints

  • Liu, T.C.H.;Davies, J.M.
    • Steel and Composite Structures
    • /
    • v.1 no.4
    • /
    • pp.427-440
    • /
    • 2001
  • The growing use of unprotected or partially protected steelwork in buildings has caused a lively debate regarding the safety of this form of construction. A good deal of recent research has indicated that steel members have a substantial inherent ability to resist fire so that additional fire protection can be either reduced or eliminated completely. A performance based philosophy also extends the study into the effect of structural continuity and the performance of the whole structural totality. As part of the structural system, thermal expansion during the heating phase or contraction during the cooling phase in most beams is likely to be restrained by adjacent parts of the whole system or sub-frame assembly due to compartmentation. This has not been properly addressed before. This paper describes an experimental programme in which unprotected steel beams were tested under load while it is restrained between two columns and additional horizontal restraints with particular concern on the effect of catenary action in the beams when subjected to large deflection at very high temperature. This paper also presents a three-dimensional mathematical modelling, based on the finite element method, of the series of fire tests on the part-frame. The complete analysis starts with an evaluation of temperature distribution in the structure at various time levels. It is followed by a detail 3-D finite element analysis on its structural response as a result of the changing temperature distribution. The principal part of the analysis makes use of an existing finite element package FEAST. The effect of columns being fire-protected and the beam being axially restrained has been modelled adequately in terms of their thermal and structural responses. The consequence of the beam being restrained is that the axial force in the restrained beam starts as a compression, which increases gradually up to a point when the material has deteriorated to such a level that the beam deflects excessively. The axial compression force drops rapidly and changes into a tension force leading to a catenary action, which slows down the beam deflection from running away. Design engineers will be benefited with the consideration of the catenary action.

Hazard Analysis, Determination of Critical Control Points, and Establishment of Critical Limits for Seasoned Laver (조미김의 제조공정별 위해요소분석, 중요관리점 결정 및 한계기준 개발)

  • Kang, Min Jeong;Lee, Hak Tae;Kim, Jung Yun
    • Culinary science and hospitality research
    • /
    • v.21 no.2
    • /
    • pp.1-10
    • /
    • 2015
  • The purpose of this study was to establish the critical limit of CCP (Critical Control Point) of a HACCP (Hazard Analysis Critical Control Point) system used in the production of seasoned laver products. The hazard analysis examined microbial evaluations and developed a HACCP management plan for the heating process. The results were determined to be capable of reducing the biological element of CCP via the secondary roasting process. This study examined general bacteria and pathogenic microorganisms such as Escherichia coli, Staphylococcus aureus, Salmonella spp., Listeria monocytogenes, Vibrio parahaemolyticus, and Bacillus cereus at temperatures ranging from $170^{\circ}C$ to $230^{\circ}C$ and for 3.0 to 5.5 seconds at a time. Before the secondary roasting process, pathogenic microorganisms were all negative, although the presence of general bacteria was still detected. General bacteria was reduced to $1.0{\times}10CFU/g$ after the temperature was set at $230^{\circ}C$ for a period of 5.5 seconds. In conclusion, it suggested that a HACCP plan was necessary for management standard and systematic approach in the establishment of critical limit, problem resolution, verification method, education, and records management through a secondary roasting process.

Changes in Rural Health and Environmental Factors (2001-2010) A Comparison between Agricultural and Nonagricultural Groups (농촌 환경ㆍ건강 지표의 변화 추이(2001~2010년) -농촌 거주 농업종사자와 비농업종사자의 비교-)

  • Rhie, Seung Gyo;Hwang, Jeong-Im;Won, Hyang Rye
    • The Korean Journal of Community Living Science
    • /
    • v.25 no.1
    • /
    • pp.99-111
    • /
    • 2014
  • To verify welfare needs, rural health and environmental factors were compared between agricultural and nonagricultural groups over the past 10 years. Based on a survey of rural life by the Rural Development Administration, whose sample included agricultural (72.8%) and nonagricultural (27.2%) groups, all factors were analyzed using SAS ( 9.3). For rural home heating, the use of oil boilers (77.2%-78.0%) decreased (53.0%-53.7%) over the same period, whereas that of electric boilers increased (21.9% and 13.5% for agricultural and nonagricultural groups, respectively). The joint water- supply increased, and the use of flush toilets (52.4% to 84.5% in the agricultural group and 64.6% to 81.4% in the nonagricultural group) and hot-water bathing was higher in the agricultural group (79% to 92.6%) than in the nonagricultural group (72.2% to 87.6%) at the p<0.001 level. Incineration accounted for the largest portion of household waste until 2006, when it was replaced by other treatment methods such as the pay-per-treatment option (44.4% and 68.3% in the agricultural and nonagricultural groups, respectively) (p<0.001). Garbage disposal in 2001 was mainly burial or animal feed, but separate collection increased in 2010 (42.2% and 64.3% in the agricultural and nonagricultural groups, respectively) (p<0.001). The self-perception of health was lower in the agricultural group than in the nonagricultural group (2.96 to 2.74 on a five-point scale in the agricultural group and 3.07 to 2.98 in the nonagricultural group). Drinking decreased less in the agricultural group (criteria: one point once a week,; 1.48 to 1.20) than in the nonagricultural group (1.13 to 0.80) at p<0.001, and a similar pattern was found for smoking (p<0.001). Health screening decreased in the last 10 years (scoring based one point/1-2 times per year,: 0.94 to 0.64 in the agricultural group and 1.08 to 0.69 in the nonagricultural group;p<0.01). These results indicate that various health and environmental factors were less favorable to farmers except for bathing in comparison to nonagricultural living in the same area. This suggests that people in agriculture are less likely to live and work in favorable environments than those outside the sector and thus indicates a need for more attention to the national health welfare system for farmers for systematic realization.

Heat Transfer Characteristics of Water Jet Impinging on Oblique Surface (경사면(傾斜面)에 충돌(衝突) 하는 수분류(水噴流)의 열전달(熱傳達) 특성(特性)에 관(關)한 연구(硏究))

  • Choi, Guk-Gwang;Na, Gi-Dae;Kim, Yeun-Young;Jeon, Sung-Taek;Lee, Jong-Su
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 1993
  • The purpose of this research is to investigate the characteristics of heat transfer in the downward axisymmetric free water jet system impinged on a flat oblique plate which has the uniform heat flux. Experimental conditions considered were Reynolds number, distance between nozzle and Bat plate, inclination angle of heater surface and nozzle exit velocity. Local Nusselt number was subjected to the influence of Re number, Pr number, oblique angle of heating surface and local position of flat plate. In the wall region of downward surface, The secondary peak point of heat transfer appeared at the local point of X/D=-8 from the stagnation point. The stagnation heat transfer rate of this experimental study augments 2.4 times than that of laminar theorical solution. The stagnation nusselt number is function of Reynolds number, nozzle-plate spacing Prandtl number and oblique angle of impinging plate.

  • PDF

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s