• Title/Summary/Keyword: Point Heating System

Search Result 193, Processing Time 0.026 seconds

Abnormal Winter Melting of the Arctic Sea Ice Cap Observed by the Spaceborne Passive Microwave Sensors

  • Lee, Seongsuk;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.305-311
    • /
    • 2016
  • The spatial size and variation of Arctic sea ice play an important role in Earth's climate system. These are affected by conditions in the polar atmosphere and Arctic sea temperatures. The Arctic sea ice concentration is calculated from brightness temperature data derived from the Defense Meteorological Satellite program (DMSP) F13 Special Sensor Microwave/Imagers (SSMI) and the DMSP F17 Special Sensor Microwave Imager/Sounder (SSMIS) sensors. Many previous studies point to significant reductions in sea ice and their causes. We investigated the variability of Arctic sea ice using the daily sea ice concentration data from passive microwave observations to identify the sea ice melting regions near the Arctic polar ice cap. We discovered the abnormal melting of the Arctic sea ice near the North Pole during the summer and the winter. This phenomenon is hard to explain only surface air temperature or solar heating as suggested by recent studies. We propose a hypothesis explaining this phenomenon. The heat from the deep sea in Arctic Ocean ridges and/or the hydrothermal vents might be contributing to the melting of Arctic sea ice. This hypothesis could be verified by the observation of warm water column structure below the melting or thinning arctic sea ice through the project such as Coriolis dataset for reanalysis (CORA).

Theoretical Analyses of Autothermal Reforming Methanol for Use in Fuel Cell

  • Wang Hak-Min;Choi Kap-Seung;Kang Il-Hwan;Kim Hyung-Man;Erickson Paul A.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.864-873
    • /
    • 2006
  • As fuel cells approach commercialization, hydrogen production becomes a critical step in the overall energy conversion pathway. Reforming is a process that produces a hydrogen-rich gas from hydrocarbon fuels. Hydrogen production via autothermal reforming (ATR) is particularly attractive for applications that demand a quick start-up and response time in a compact size. However, further research is required to optimize the performance of autothermal reformers and accurate models of reactor performance must be developed and validated. The design includes the requirement of accommodating a wide range of experimental set ups. Factors considered in the design of the reformer are capability to use multiple fuels, ability to vary stoichiometry, precise temperature and pressure control, implementation of enhancement methods, capability to implement variable catalyst positions and catalyst arrangement, ability to monitor and change reactant mixing, and proper implementation of data acquisition. A model of the system was first developed in order to calculate flowrates, heating, space velocity, and other important parameters needed to select the hardware that comprises the reformer. Predicted performance will be compared to actual data once the reformer construction is completed. This comparison will quantify the accuracy of the model and should point to areas where further model development is required. The end result will be a research tool that allows engineers to optimize hydrogen production via autothermal reformation.

Abnormal Coating Buildup on Si Bearing Steels in Zn Pot During Line Stop

  • Weimin Zhong;Rob Dziuba;Phil Klages;Errol Hilado
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.83-92
    • /
    • 2024
  • A hot-dip simulator was utilized to replicate abnormal coating buildup observed during line stops at galvanize lines, assessing the influence of processing conditions on buildup (up to 14 mm/side). Steel samples from 19 coils (comprising IF, BH, LCAK, HSLA, DP600-DP1180, Si: 0.006 - 0.8 wt%, P: 0.009 - 0.045 wt%) were examined to explore the phenomenon of heavy coating growth. It was discovered that heavy coating buildup (~3 mm/h) and rapid strip dissolution (~0.17 mm/h) in a GA or GI pot can manifest with specific combinations of steel chemistry and processing conditions. The results reveal the formation of a unique coating microstructure, characterized by a blend of bulky Zeta crystals and free Zn pockets/networks due to the "Sandlin" growth mechanism. Key variables contributing to abnormal coating growth include steel Si content, anneal temperature, dew point in heating and soaking furnaces, Zn pot temperature, Zn bath Al%, and cold-rolling reduction%. At ArcelorMittal Dofasco galvanize lines, an automatic online warning system for operators and special scheduling for incoming Si-bearing steels have been implemented, effectively preventing further heavy buildup occurrences.

Performance Evaluation of IGCC Plants with Variation in Coal Rank and Coal Feeding System (탄종 및 석탄공급방식 변화에 따른 석탄가스화 복합발전 플랜트의 성능 평가)

  • 이승종;이진욱;윤용승
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.176-187
    • /
    • 1997
  • As a way to evaluate the performance of IGCC (Integrated Gasification Combined Cycle) processes, heating values of coal gas as well as plant efficiency were compared for different rank coals and coal feeding methods by employing the static process simulation technique. Performance of the process was compared with coal rank that was varied by three assorted bituminous coals and also by three subbituminous coals, in addition to the two types of feeding techniques, i.e., dry-feeding and slurry-feeding, that are utilized in entrained-bed coal gasifiers. For the verification of the simulation technique, simulated results were compared first with the actual pilot plant data published from Shell and Texaco. The simulation technique was, then, applied to other coals. Result from tests varying coal rank exhibits the trend of improving both heating content of the product gas and plant efficiency with increasing carbon content in coal. The effect of coal rank is more sensitive in slurry-feeding cases compared to the dry-feeding cases. In particular, considering notably lower values in gas heating value and plant efficiency calculated in the slurry-feeding case that uses a subbituminous coal, limited utilization of the slurry-feeding method for subbituminous coals can be expected. From the plant efficiency point of view, dry-feeding method resulted in higher simulated efficiency values by maximum 3% for subbituminous coals and ca. l% for bituminous coals.

  • PDF

A Case Study on Energy focused Smart City, London of the UK: Based on the Framework of 'Business Model Innovation'

  • Song, Minzheong
    • International journal of advanced smart convergence
    • /
    • v.9 no.2
    • /
    • pp.8-19
    • /
    • 2020
  • We see an energy fucused smart city evolution of the UK along with the project of "Smart London Plan (SLP)." A theoretical logic of business model innovation has been discussed and a research framework of evolving energy focused smart city is formulated. The starting point is the silo system. In the second stage, the private investment in smart meters establishes a basement for next stages. As results, the UK's smart energy sector has evolved from smart meter installation through smart grid to new business models such as water-energy nexus and microgrid. Before smart meter installation of the government, the electricity system was centralized. However, after consumer engagement plan has been set to make them understand benefits that they can secure through smart meters, the customer behavior has been changed. The data analytics firm enables greater understanding of consumer behavior and it helps energy industry to be smart via controlling, securing and using that data to improve the energy system. In the third stage, distribution network operators (DNOs)' access to smart meter data has been allowed and the segmentation starts. In the fourth stage, with collaboration of Ofwat and Ofgem, it is possible to eliminate unnecessary duplication of works and reduce interest conflict between water and electricity. In the fifth stage, smart meter and grid has been integrated as an "adaptive" system and a transition from DNO to DSO is accomplished for the integrated operation. Microgrid is a prototype for an "adaptive" smart grid. Previous steps enable London to accomplish a platform leadership to support the increasing electrification of the heating and transport sector and smart home.

An Experimental Analysis of Hydrate Production using Multi-Well, Plate-Type Cell Apparatus (다중공 평판형 셀기기에서 하이드레이트 생산실험 분석연구)

  • Bae, Jaeyu;Sung, Wonmo;Kwon, Sunil
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.304-309
    • /
    • 2007
  • In this study, the "Multi Well Plate-type cell Apparatus" was designed and setup for performing the producing experiments of methane hydrate by depressurization, heat stimulating methods. In order to characterizing the producing mechanism of hydrate through porous materials, the experiments for various producing methods have been conducted with the aid of the apparatus which has high permeability. In the experimental result of depressurization method, the pressure is temporarily increased unlikely conventional gas reservoir due to the sourcing effect of hydrate dissociation in the pore. Meanwhile, the temperature is decreased because of the endothermic reaction while hydrate is dissociated. In the experimental results of heat stimulating method, the dissociation in depressurization method is more slowly processed than that in thermal method, and hence, its gas production is lower. In the case of production right after heating, hydrate is dissociated only near injecting point and the permeability becomes greater at that area only. It infers that the more gas is produced during relatively earlier producing period. Since then, the hydrate is more slowly dissociated than the case of production after heating and soaking. This time, the performances of pressure and production obtained by thermal method have been analyzed in order to investigate the effect of soaking time on gas recovery. As a result, the gas recoveries in the case of 2 min and 4 min soaking are higher than case in 6 min soaking. This is reason that hydrate is reformed due to the decrease of temperature. It is expected that the experimental results obtained in this work may be more clearly explained by utilizing the lower permeable porous system with the greater hydrate saturation.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

Construction and Comparison of Sound Quality Index for the Vehicle HVAC System Using Regression Model and Neural Network Model (회귀모형과 신경망모형을 이용한 차량공조시스템의 음질 인덱스 구축 및 비교)

  • Park, Sang-Gil;Lee, Hae-Jin;Sim, Hyun-Jin;Lee, You-Yub;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.897-903
    • /
    • 2006
  • The reduction of the vehicle interior noise has been the main interest of noise and vibration harshness (NVH) engineers. The driver's perception on the vehicle noise is affected largely by psychoacoustic characteristic of the noise as well as the SPL. In particular, the heating, ventilation and air conditioning (HVAC) system sound among the vehicle interior noise has been reflected sensitively in psychoacoustics view point. Even though the HVAC noise is not louder than overall noise level, it clearly affects subjective perception to drivers in the way of making to be nervous or annoyed. Therefore, these days a vehicle engineer takes aim at developing sound quality as well as reduction of noise. In this paper, we acquired noises in the HVAC from many vehicles. Through the objective and subjective sound quality (SQ) evaluation with acquiring noises recorded by the vehicle HVAC system, the simple and multiple regression models were obtained for the subjective evaluation 'Pleasant' using the semantic differential method (SDM). The regression procedure also allows you to produce diagnostic statistics to evaluate the regression estimates including appropriation and accuracy. Furthermore, the neural network (NN) model were obtained using three inputs(loudness, sharpness and roughness) of the SQ metrics and one output(subjective 'Pleasant'). Because human's perception is very complex and hard to estimate their pattern, we used NN model. The estimated models were compared with correlations between output indexes of SQ and hearing test results for verification data 'Pleasant'. As a result of application of the SQ indexes, the NN model was shown with the largest correlation of SQ indexes and we found possibilities to predict the SQ metrics.

A Simulation for the Stratified Thermal Storage System in Residential Solar Energy Application (주거용 태양열 성층축열시스템의 시뮬레이션)

  • Pak, Ee-Tong;Yoo, Ho-Seon
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.44-52
    • /
    • 1991
  • The benefits of thermal stratification in sensible heat storage systems has been considered and studying by several investigators. In this paper, the basic data which is hard to obtain normally through the experiment were obtainable through the computer simulation. The major objectives of the study were to assess the benefits of stratified storage in residential solar water heating application and to suggest the optimum design parameters. From the computer simulation, following results were obtained. 1. The solar load fraction increases with increasing the number of tank segments. In these simulation, the magnitude of the improvement was about 10%. 2. The solar load fraction increases when the ratio of diameter to height of the tank(H/D) increases to 3, but H/D exceed 3 then, the solar load fraction decreases. In these simulation, the magnitude of the improvement was about 3%. 3. Increasing the collector flow rate slightly improved the performance of the mixed storage system(Node=1). But, for the stratified storage system(Node=N), the solar load fraction increases with decreasing flow rate until the point is reached at which the collector outlet temperature reaches the boiloff limit of $100^{\circ}C$ over some portion of the simulation period.

  • PDF

Analysis of Bonding Characteristics of Ag-System Brazing Filler Metal (은계 필러메탈 브레이징 접합부의 특성 분석)

  • Soon-Gil Lee;Hwa-In Lee;Jin-Oh Son;Gwang-Il Ha;Bon-Heun Koo
    • Korean Journal of Materials Research
    • /
    • v.33 no.5
    • /
    • pp.214-221
    • /
    • 2023
  • As a filler metal for lowering the melting point of Ag, many alloy metal candidates have emerged, such as cadmium, with zinc, manganese, nickel, and titanium as active metals. However, since cadmium is known to be harmful to the human body, Cd-free filler metals are now mainly used. Still, no study has been conducted comparing the characteristics of joints prepared with and without cadmium. In addition, studies have yet to be conducted comparing the typical characteristics of brazing filler metals with special structures, and the joint characteristics of brazing filler metals with available frames. In this study, the characteristics of junctions of silver-based intercalation metals were compared based on the type of filler metal additives, using a special structure, a filler metal sandwich structure, to protect the internal base metal. The general filler metal was compared using the structure, and the thickness of the filler metal according to the thickness was reached. A comparison of the characteristics of the junction was conducted to identify the characteristics of an intersection of silver-based brazing filler metal and the effect on joint strength. Each filler metal's collective tensile strength was measured, and the relationship between joint characteristics and tensile joint strength was explored. The junction was estimated through micro strength measurement, contact angle measurement with the base metal when the filler metal was melted, XRD image observation, composition analysis for each phase through SEM-EDS, and microstructure phase acquisition.