• Title/Summary/Keyword: Pohang Light Source (PLS)

Search Result 47, Processing Time 0.021 seconds

Capacitive Voltage Divide for a Pulsed High-Voltage Measurement (펄스형 고전압 측정용 용량성 분압기)

  • Jang Sung-Duck;Son Yoon-Kyoo;Kwon Sei-Jin;Oh Jong-Seok;Cho Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.63-68
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source are under operation for 2.5 GeV electron linear accelerator in Pohang Light Source (PLS) linac. The klystron-modulator system has an important role for the stable operation to improve an availability statistics of overall system performance of klystron-modulator system. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are demanded for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider (CVD), which divides input voltage as capacitance ratio, is intended for the measurement of a beam voltage of 400 kV generated from the klystron-modulator system. Main parameter to determine standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will be present and discuss the design concept and analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance effects and oil temperature variation.

X-ray Scattering Study of Reactive Sputtered Ta-N/Ta/Si(001)Film as a Barrier Metal for Cu Interconnection (구리배선용 베리어메탈로 쓰이는 Ta-N/Ta/Si(001)박막에 관한 X-선 산란연구)

  • Kim, Sang-Soo;Kang, Hyon-Chol;Noh, Do-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.79-83
    • /
    • 2001
  • In order to compare the barrier properties of Ta-N/Si(001) with those of Ta-N/Ta/Si(001), we studied structural properties of films grown by RF magnetron sputtering with various $Ar/N_2$ ratios. To evaluate the barrier properties, the samples were annealed in a vacuum chamber. Ex-situ x-ray scattering measurements were done using an in-house x-ray system. With increasing nitrogen ratio in Ta-N/Si(001), the barrier property of Ta-N/Si(001) was enhanced, finally failed at $750^{\circ}C$ due to the crystallization and silicide formation. Compared with Ta-N/Si(001), Ta-N/Ta/Si(001) forms silicides at $650^{\circ}C$. However it does not crystallize even at $750^{\circ}C$. With increasing nitrogen composition in Ta-N/Ta/Si(001), the formation of tantalum silicide was reduced and the surface roughness was improved. To observe the surface morphology of Ta-N/Ta/Si(001) during annealing, we performed an in-situ x-ray scattering experiment using synchrotron radiation of the 5C2 at Pohang Light Source(PLS). Addition of Ta layer between Ta-N and Si(001) improved the surface morphology and reduced the surface degradation at high temperatures. In addition, increasing $N_2/Ar$ flow ratio reduced the formation of tantalum silicide and enhanced the barrier properties.

  • PDF

A Compression Study on a Synthetic Talc (합성 활석에 대한 압축 연구)

  • Kim, Young-Ho;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.283-291
    • /
    • 2014
  • Talc ($Mg_3Si_4O_{10}(OH)_2$), one of sheet silicates, is soft and has been widely used in industry. Powdered talc specimen was synthesized at the pressure of 200 MPa and temperature of $600^{\circ}C$ using external heated hydrothermal high pressure apparatus. High pressure angular dispersive X-ray diffraction (ADXRD) mode experiments were performed at the Pohang Light Source (PLS) using the symmetrical diamond anvil cell (SDAC). Compression pressure was loaded up to 11.06 GPa at room temperature. This synthetic talc shows no phase transition(s) within the present pressure limit. Based on ADXRD data, bulk modulus of talc was calculated to be 72.4 GPa using Birch-Muranghan equation of state (EOS). This value is lower than that of natural talc determined previously.

Compressibility of $FeS_{2}$ ($FeS_{2}$의 압축성 연구)

  • Kim, Young-Ho;Hwang, Gil-Chan;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.189-195
    • /
    • 2006
  • Compression work on a pyrite powder has been carried out using energy dispersive X-ray diffraction (EDXRD) with Mao-Bell type diamond anvil cell (DAC) and synchrotron radiation(SR) at room temperature. It has been reported the bulk moduli of pyrite show the large variations depending on the experimental conditions as well as the apparatus used. Thus, two kinds of sample in different pressure transmitting media of both NaCl and MgO powder emerged in alcoholic fluids were subjected to measure their compressibilities. Bulk moduli thus obtained are 138.9 GPa and 198.2 GPa, respectively, and this result contradicts to the anticipated values according to the hydrostaticity conditions of the sample chamber. This might be due to the alcoholic fluids phase transition mainly with the side effects from the difference of both solid state detector (SSD) used and E*d value applied. All experiments were performed at the Beam Line 1B2 of Pohang Light Source (PLS).

$La_{0.7}Ca_{0.3-x}Ba_xMnO_3$ manganites : Local structure and transport properties

  • A.N.Ulyanov;Yang, Dong-Seok;Yu, Seong-Cho
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.8-8
    • /
    • 2003
  • Electron-phonon interaction plays a significant role in forming of colossal magnetoresistance effect (CMR). Polaron formation was observed by neutron diffraction and by extended X-ray absorption fine structure (EXAFS) analysis. Local probe as given by the EXAFS is a useful method to study the polaronic charge and its dependence on temperature and ions size. Here we present the EXAFS study of polaronic charge in La/sub 0.7/Ca/sub 0.3-X/Ba/sub X/MnO₃ compositions. The single phase La/sub 0.7/Ca/sub 0.3-X/Ba/sub X/MnO₃ manganites (x=0; 0.03; 0.06, ..., 0.3) were prepared by ceramic technology [1]. The Curie temperature was determined by extrapolation of the temperature dependence of the magnetization (down to zero magnetization). EXAFS experiments were carried out at the 7C EC beam line of the Pohang Light Source (PLS) in Korea. The atomic pair distribution functions (PDF) were obtained by re-regularization method [2] from filtered spectra. The PDF for the x=0.3 sample showed a single peak function and for x=0.0, 0.03, 0.06, 0.09, 0.12 compositions were asymmetric in agreement with a small Jahn-Teller elongation of two (short and long) bonds of the MnO/sub 6/ octahedron. Dispersion, σ/sub Min-O//sup 2/, and asymmetry, σ/sub Min-O//sup 3/, of the Mn-O bond distances varied significantly with x and showed a maximums at x=0.09. The maximum of σ/sub Min-O//sup 2/ is caused by increase of dynamic rms displacements of the Mn-O distances near the T/sub C/. The observed x dependence of σ/sub Min-O//sup 3/ reflects the reduction of charge carriers mobility at approaching to T/sub C/ from low as well as high temperatures.

  • PDF

A Study of Compressibility on a Natural Almandine Using Synchrotron Radiation (방사광을 이용한 천연산 알만딘의 압축성 연구)

  • Hwang Gil Chan;Kim Young-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.4 s.46
    • /
    • pp.249-257
    • /
    • 2005
  • Garnet is one of the major minerals down to the top of lower mantle approximately 660 km with spinel and pyroxenes. Garnet transforms into perovskite and corundum in the lower mantle, however its sequence is still in controversy. We measured the compressibility of a natural almandine at high-pressure up to 62 CPa using Mao-Bell type diamond anvil cell (DAC) at room temperature. Chemical formula of the specimen is ($Fe_{2.52}Ca_{0.21}Mg_{0.18}Mn_{0.12})Al_{2.23}Si_{2.97}O_{12}$. Results of this compression study are as follows: a : $10.175\;{\AA}$, V : $1251.16\;{\AA}^{3}$, $D_{x}$ : $5.265\;g/cm^{3}$ at 62 GPa; bulk modulus is 156 GPa using Birch-Murnaghan equation of state (EoS) with a fixed $K_{0}\;'$ of 4. This study would be the first time attempt accomplished with the high pressure DAC using synchrotron radiation at the Pohang Light Source (PLS) in Korea.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF