• 제목/요약/키워드: Pneumatic system

검색결과 546건 처리시간 0.031초

관로의 전달 특성을 고려한 공기압 실린더 위치 제어계의 모델링 (Modeling of a Pneumatic Cylinder Position Control system Considering Transfer Characteristics of a Transmission Line)

  • 장지성;강보식;지상원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.731-736
    • /
    • 2004
  • In this study, a linearized model of pneumatic cylinder position control system including transmission line is proposed. The transmission line using compressible fluid has a nonlinear transfer characteristics because that the frequency response of it is changed by the flowing state of the fluid. But, when the pressure difference between both sides of transmission line is low, the effect of resonance characteristics of it under high frequency range can be neglected because of the friction force and low pass characteristics of the position control system. Therefore, the transmission line can be modeled by second order transfer function and the natural frequency, damping ratio and gain are changed by the diameter and length of it. The effectiveness of the proposed model is proved by comparison of simulation results using proposed model with experimental results and simulation results using conventional model.

  • PDF

The Development of a Flood Protection System for Pad Transformers Using Pneumatic Pressure in Areas Prone to Floods

  • Kim, Gi-Hyun;Lee, Jae-Yong;Bae, Suk-Myong
    • 조명전기설비학회논문지
    • /
    • 제24권3호
    • /
    • pp.27-32
    • /
    • 2010
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown areas and low-lying shores by torrential rain, typhoons and tsunamis. It has, in turn, caused replacement, social and economic costs for blackouts. For activity management regarding flood damage we produced a flood protection system which using the Pad transformer as a basic frame and is developed using pneumatic pressure. We tested safety concerns including insulation resistance and current leakage first for water tank flooding and, second, by an empirical test through supplying 22.9[kV]. We estimate that costs associated with flooding and power failure can be diminished by these advances toward creating a more reliable system.

압전 작동기로 구동 되는 공압 밸브의 $H_{\infty}$ 압력제어 ([ $H_{\infty}$ ] Pressure Control of Pneumatic Valve Driven by Piezoactuators)

  • 유중규;조명수;최승복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.673-678
    • /
    • 2001
  • This paper proposes a new type of piezoactuator-driven valve system. The piezoceramic actuator bonded to both sides of a flexible beam surface makes a movement required to control the pressure at the flapper-nozzle of a pneumatic valve system. After establishing a dynamic model, an appropriate size of the valve system is designed and manufactured. Subsequently, a robust $H_{\infty}$ control algorithm is formulated in order to achieve accurate tracking control of the desired pressure. The controller is experimentally realized and control performance for the sinusoidal pressure trajectory is presented in time domain. The control bandwidth of the valve system, which directly represents the fastness, is also evaluated in the frequency domain.

  • PDF

감쇄피스톤을 이용한 공압구동장치 설계 (Development of A Pneumatic Actuation System with Damping Pist)

  • 문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.370-375
    • /
    • 1987
  • Damping piston with an orifice in the piston head is utilized to improve the damping characteristics of a pneumatic push-push type rotary actuator. Through linearized analysis, the optimum size of orifice, which gives maximum damping effect at the frequency where damping is desired. most, is predicted. The frequency response test of teal system were carried out to see the effects of damping piston and to obtain true optimum size of orifice by trying orifices of various size near the predicted value. During the tests, both air and helium were tried as working fluid, and a lag-lead compensation circuit was incorporated to improve system dynamics. The finally chosen orifice size is a little bigger than that predicted from analysis, however it gives high damping effects for the finally designed pneumatic system enough to have wide frequency response bandwidth.

  • PDF

압축공기를 이용한 에어호이스트의 무중력화 제어 (Weightless Control of Air Hoist using Compressed Air)

  • 이강호;배상일;홍대선;정원지
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.144-144
    • /
    • 2000
  • Air balance hoists are widely used in handling of heavy materials in industry. Currently used air balance hoists adopt manual switches for vertical motion, thus the operator has a difficulty in operating of the switches and handling of material simultaneously. To overcome this difficulty, this study develops a weightless air-balance-hoist system using compressed air. This system memorizes the weight of material in terms of pneumatic pressure with a pneumatic circuit. Such memory of the material weight is used for achieving weightless handling of materials. Through a series of experiments, handling forces and the response of the system for various material weights are analyzed. The results show that the developed system can be used for weightless handling o( heavy materials.

  • PDF

압축성유체 유량계측장치 설계 및 제작 (Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid)

  • 지상원;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권4호
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

Fuzzy rule을 이용한 공압 서보 제어 알고리즘의 개발 (Development of pneumatic servo control algorithm using fuzzy rule)

  • 박상덕;정규원;염영일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1127-1132
    • /
    • 1991
  • Pneumatic control system has been used mainly for endpoint position control because of the compressibility, viscosity and low output stiffness of air which causes nonlinear flow characteristics. In this paper, pneumatic position control algorithms using fuzzy rule were developed to achieve faster and more stable response than conventional PI control algorithm. The performances of the proposed algorithms were compared by computer simulations with them of PI controller. From those simulations it was shown that the proposed algorithms are more efficient about settling time, steady state error and overshoot than PI control algorithm.

  • PDF

불균일 입도를 가지는 기류식 고체 처리 시스템을 위한 해석모델 (Analysis model for the pneumatic solid processing system in non-uniform particle size condition)

  • 최동환;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.229-231
    • /
    • 2015
  • In pneumatic reactor, hydrodynamic relation between gas and solid is important and particle size has a significant effect on this relation. In this reason, we analyzed drying and calcine process with a corrected model by considering the effect of the particle size distribution(PSD) with different seven particle groups by particle size.

  • PDF

인조신경망을 이용한 좌심실보조장치의 동적 모델링

  • 김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.346-350
    • /
    • 1996
  • This paper presents a Neural Network Identification (NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulation system of Left Ventricular Assist Device(LVD). This system consists of electronic circuits and pneumatic driving circuits. The initation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded. System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, Heart Rate(HR), Systole-Diastole Rate(SDR), which can vary state of system, and preload, afterload, which indicate the systemic dynamic characteristics and output parameters are preload, afterload.

  • PDF

적층형 압전액추에이터 방식 전-공 레귤레이터 (Electro-pneumatic regulator using multilayer PZT actuator)

  • 윤소남;김찬용;박중호;윤동원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.979-984
    • /
    • 2007
  • This paper presents a new control mechanism for the proportional pressure control which is accomplished by electro-pneumatic regulator using two PZT actuators. The electro-pneumatic regulator of this study is 2-stage type and consists of two piezoelectric actuators, a controller and a main poppet valve. The piezoelectric actuators are multilayer bender type and are controlled by digital signal. Proportional pressure control technique is very important because that can derive improvement of product quality and driving ability in the pneumatic system. Solenoid actuator method for pressure control is widely used but this actuator has a high power consumption characteristics. So new actuator is required for the energy saving. In this study, PZT actuator for the pressure control was fabricated and experimented instead of the conventional type solenoid actuator. Experiments for the new control mechanism of the elector-pneumatic regulator were operated under the input condition of 0.4[MPa] and it was confirmed that this mechanism has a good control characteristics to the response sensitivity and hysteresis.

  • PDF