• 제목/요약/키워드: Pneumatic robot

검색결과 57건 처리시간 0.025초

유연한 공압인공근육로봇의 강건제어 (Robust control of a flexible manipulator with artificial pneumatic muscle actuators)

  • 박노철;박형욱;박영필;정승호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1704-1707
    • /
    • 1997
  • In this work, position and vibratiion control of a two-link manipulator with one flexible link, which an unkoun but bounded payload mass and two pair of artificial muscle-type penumatic actuators, are investgated. A flexible link robot has advantages over a figid link robot in the sense that it is much safer when it cones into contact with its environment, including humans. Furthermore, for the sake of safety, it would be more desirabel if an actuator could deliver required force while maintaining proper compliance. An artificial muscle-type penumatic actuator is adequate for such cases. In this study, a controller based on singular perturbation method, adaptive and sliding mode contro, and .mu.-synthesis is developed. The effectiveness of the proposed control scheme is confirmed through simulations and experiments.

  • PDF

면취없는 부품의 조립을 위한 로보트 손목기구의 개발 (Development of a Robot Wrist for the Assembly of Chamferless Parts)

  • 권대갑;정충민
    • 한국정밀공학회지
    • /
    • 제9권2호
    • /
    • pp.36-43
    • /
    • 1992
  • In this paper, a robot assembly wrist, which is able to assemble chamferless parts, has been developed. The RCC (Remote Center Compliance) structure is used as a basic structure. 5 position sensors and 4 pneumatic actuators are installed additionally to measure the deformation of RCC structure and correct the errors actively. Due to the restricted direction of actuation, a decision rule which selects the suitable actuator according to the position sensor signals is needed. For this purpose, a neural network is used and it is experimentally shown that the nerual network overcomes system's nonlinearity. This paper presents fundamental experiment results for the insertion of parts with several clearance.

  • PDF

근접 센서를 이용한 로봇 손의 파지 충격 개선 (Grasping Impact-Improvement of Robot Hands using Proximate Sensor)

  • 홍예선;진성무
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.42-48
    • /
    • 1999
  • A control method for a robot hand grasping a object in a partially unknown environment will be proposed, where a proximate sensor detecting the distance between the fingertip and object was used. Particularly, the finger joints were driven servo-pneumatically in this study. Based on the proximate sensor signal the finger motion controller could plan the grasping process divided in three phases ; fast aproach, slow transitional contact and contact force control. That is, the fingertip approached to the object with full speed, until the output signal of the proximate sensor began to change. Within the perating range of the proximate sensor, the finger joint was moved by a state-variable feedback position controller in order to obtain a smooth contact with the object. The contact force of fingertip was then controlled using the blocked-line pressure sensitivity of the flow control servovalve for finger joint control. In this way, the grasping impact could be reduced without reducing the object approaching speed. The performance of the proposed grasping method was experimentally compared with that of a open loop-controlled one.

  • PDF

자율주행 내시경을 위한 공압 구동방식의 이동메카니즘 (Locomotive Mechanism Based on Pneumatic Actuators for the Semi-Autonomous Endoscopic System)

  • 김병규;김경대;이진희;박종오;김수현;홍예선
    • 제어로봇시스템학회논문지
    • /
    • 제8권4호
    • /
    • pp.345-350
    • /
    • 2002
  • In recent years, as changing the habit of eating, the pathology in the colon grows up annually. The colonoscopy is generalized, but if requires much time to acquire a dexterous skill to perform an operation and the procedure is painful to the patient. biomedical and robotic researchers are developing a locomotive colonoscope that can travel safe1y in colon. In this paper, we propose a new actuator and concept of semi-autonomous colonoscope. The micro robot comprises camera and LED for diagnosis, steer- ing system to pass through the loop, pneumatic actuator and bow-shaped flexible supporters to control a contact force and to pass over haustral folds in colon. For locomotion of semi-autonomous colonoscope, we suggest an actuator that is based on impact force between a cylinder and a piston. In order to validate the concept and the performance of the actuator, we carried out the simulation of moving characteristics and the preliminary experiments in rigid pipes and on the colon of pig.

관로 청소 로봇의 최적 설계 (Optimal Mechanism Design of In-pipe Cleaning Robot)

  • 정창두;정원지;안진수;신기수;권순재
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.123-129
    • /
    • 2012
  • Recently, interests on cleaning robots workable in pipes (termed as in-pipe cleaning robot) are increasing because Garbage Automatic Collection Facilities (i.e, GACF) are widely being installed in Seoul metropolitan area of Korea. So far research on in-pipe robot has been focused on inspection rather than cleaning. In GACF, when garbage is moving, the impurities which are stuck to the inner face of the pipe are removed (diameter: 300 mm or 400 mm). Thus, in this paper, by using TRIZ (Inventive Theory of Problem Solving in Russian abbreviation), an in-pipe cleaning robot of GACF with the 6-link sliding mechanism will be proposed, which can be adjusted to fit into the inner face of pipe using pneumatic pressure(not spring). The proposed in-pipe cleaning robot for GACF can have forward/backward movement itself as well as rotation of brush in cleaning. The robot body should have the limited size suitable for the smaller pipe with diameter of 300 mm. In addition, for the pipe with diameter of 400 mm, the links of robot should stretch to fit into the diameter of the pipe by using the sliding mechanism. Based on the conceptual design using TRIZ, we will set up the initial design of the robot in collaboration with a field engineer of Robot Valley, Inc. in Korea. For the optimal design of in-pipe cleaning robot, the maximum impulsive force of collision between the robot and the inner face of pipe is simulated by using RecurDyn(R) when the link of sliding mechanism is stretched to fit into the 400 mm diameter of the pipe. The stresses exerted on the 6 links of sliding mechanism by the maximum impulsive force will be simulated by using ANSYS$^{(R)}$ Workbench based on the Design Of Experiment(in short DOE). Finally the optimal dimensions including thicknesses of 4 links will be decided in order to have the best safety factor as 2 in this paper as well as having the minimum mass of 4 links. It will be verified that the optimal design of 4 links has the best safety factor close to 2 as well as having the minimum mass of 4 links, compared with the initial design performed by the expert of Robot Valley, Inc. In addition, the prototype of in-pipe cleaning robot will be stated with further research.

3D 프린팅을 활용한 전동식 재활용 웨어러블 로봇 손 시스템의 설계 및 구현 (Design and Implementation of Motor-Based Rehabilitation Wearable Robot Hand System using 3D Printing)

  • 김현준;김정현;백수황
    • 한국전자통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.941-946
    • /
    • 2021
  • 본 논문은 3D프린터와 모터를 활용해 무게와 부피를 줄인 재활용 웨어러블 로봇 손의 설계 및 구현에 관한 연구이다. 재활용 웨어러블 로봇은 재활의 효과도 중요하지만, 사용의 간편성 또한 중요하다. 하지만 현재 연구 및 개발된 재활용 외골격 로봇은 부피와 무게가 무겁거나 제자리에서 사용해야 하는 것이 대부분이다. 따라서 착용에 용이하고 사용자에게 중량이 부담되지 않는 웨어러블 로봇이 필요하므로 경량화된 전동식 재활용 웨어러블 로봇 손을 제안하였다. 3D프린터를 사용하여 무게와 부피를 줄이고 착용에 용이하도록 설계를 진행하였다. 또한, 휴대성을 높이기 위해 공압 방식이 아닌 모터기반의 전동방식을 채택해 구조를 간단하게 구성하였다. 최종적으로 경량화된 전동식 재활용 웨어러블 로봇 손의 실험을 통해 제안한 방식의 효용성을 검토하였다.

ERF와 산업용 콘트롤러를 이용한 FHA의 제어특성에 관한 연구 (A Study on the Control Characteristics of FHA by Using ERF and Industrial Controller)

  • 정성철
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.95-100
    • /
    • 2005
  • Making the best use of the features of the electro-rheological(ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. In addition, the performance of the plate type ER-Valve is investigated by change the particle concentration of the ER fluid. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power control system. Using the minかnぉd pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system fir the ER Valve which occurs from industrial controller(PLC).

공압제어를 통한 2DOF 팽창식 관절 액추에이터 제작 (Manufacturing 2DOF Inflatable Joint Actuator by Pneumatic Control)

  • 오남수;이한얼;로드리그 휴고
    • 로봇학회논문지
    • /
    • 제13권2호
    • /
    • pp.92-96
    • /
    • 2018
  • In this paper, a soft robotic arm which can prevent impact injury during human-robot interaction is introduced. Two degrees of freedom joint are required to realize free movement of the robotic arm. A robotic joint concept with a single degree of freedom is presented using simple inflatable elements, and then extended to form a robotic joint with two degrees of freedom joint using similar manufacturing methods. The robotic joint with a single degree of freedom has a joint angle of $0^{\circ}$ bending angle when both chamber are inflated at equal pressures and maximum bending angles of $28.4^{\circ}$ and $27.1^{\circ}$ when a single chamber if inflated. The robotic joint with two degrees of freedom also has a bending angle of $0^{\circ}$ in both direction when all three chambers are inflated at equal pressures. When either one or two chambers were pressurized, the robotic joint performed bending towards the uninflated chambers.

가상현실 대화용 가상걸음 장치의 설계 (Design of a Virtual Walking Machine for Virtural Reality Interface)

  • 윤정원;류제하
    • 제어로봇시스템학회논문지
    • /
    • 제10권11호
    • /
    • pp.1044-1051
    • /
    • 2004
  • This paper described a novel locomotion interface that can generate infinite floor for various surface, named as virtual walking machine. This interface allows users to participate in a life-like walking experience in virtual environments, which include various terrains such as plains, slopes and stair ground surfaces. The interface is composed of two three-DOF (X, Y, Yaw) planar devices and two four-DOF (Pitch, Roll, Z, and relative rotation) footpads. The planar devices are driven by AC servomotors for generating fast motions, while the footpad devices are driven by pneumatic actuators for continuous support of human weight. To simulate natural human walking, the locomotion interface design specification are acquired based on gait analysis and each mechanism is optimally designed and manufactured to satisfy the given requirements. The designed locomotion interface allows natural walking(step: 0.8m, height: 20cm, load capability: 100kg, slope:30deg) for various terrains.

Development of Force Reflecting Joystick for Field Robot

  • Song, In-Sung;Ahn, Kyung-Kwan;Yang, Soon-Yong;Lee, Byung-Ryong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.132.5-132
    • /
    • 2001
  • In teleoperation field robotic system such as hydraulically actuated robotic excavator, the maneuverability and convenience is the most important part in the operation of robotic excavator. Particularly the force information is important in dealing with digging and leveling operation in the teleoperated excavator. Excavators are also subject to a wide variation of soil-tool interaction forces. This paper presents a new force reflecting joystick in a velocity-force type bilateral teleoperation system. The master system is electrical joystick and the slave system is hydraulically actuated cylinder with linear position sensor. Particularly Pneumatic motor is used newly in the master joystick for force reflection and the information of the pressure of salve cylinder is measured and utilized as the force feedback signal. Also force-reflection gain greatly affects the ...

  • PDF