• Title/Summary/Keyword: Pneumatic actuator

Search Result 125, Processing Time 0.021 seconds

Design of Current PI Controller for 2-Axis Linear Actuator (2축 선형 엑츄에이터의 전류 PI제어기 설계)

  • Zun, Chan-Young;Kim, Jae-Han;Mok, Hyung-Soo;Choe, Gyu-Ha;Lee, Jung-Min;Kim, Sang-Hoon;Kim, Tae-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.321-324
    • /
    • 2007
  • The actuators of anti-vibration system(AVS) can be separated into several types: piezoelectric actuators, pneumatic springs, cylinders, rotating motor and linear motor. The last one has some advantages, such as low noise, low vibration, simpler configuration and possibility of direct drive. The voice coil motor(VCM) is one type of linear motor, originally used in speaker system. VCM actuators are usually used in occasions that rapid and controlled motion of devices are required. In this paper, a controller which satisfies system specification(e.g. current controller bandwidth) within whole operation range is designed. For that objective, parameters as position were initially obtained with 3D FEM analysis and motor modeling was performed. A current controller in 2-axis VCM drive system was designed and then performance of the proposed controller was verified with simulation using Simplorer and an experimental result.

  • PDF

Dynamic Modeling and Pressure Control of Piezoactuator Based Valve Modulator Integrated with Flexible Flapper (유연 플래퍼와 연계한 압전 밸브 모듈레이터의 동적 모델링 및 압력 제어)

  • Jeon, Jun-Cheol;Maeng, Young-Jun;Sohn, Jung Woo;Choi, Seung-Bok;Lee, Soo-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.976-982
    • /
    • 2010
  • This paper proposes a novel type of pressure control mechanism which can apply to vehicle ABS (anti-lock braking system) utilizing the piezoactuator based valve system associated with the pressure modulator. As a first step, a flapper-nozzle of a pneumatic valve system is devised by integrating the piezoacuator to the flexible beam structure. The dynamic modeling of the valve system is then undertaken and subsequently the governing equation of pressure control is derived considering the pressure modulator. A sliding mode controller is designed in order to achieve accurate pressure tracking control in the presence of actuator uncertainty as well as input pressure variation. It is shown through computer simulation that an accurate pressure tracking for sinusoidal motion whose magnitude is 40 bar is achieved by utilizing the proposed pressure control mechanism.

A Evaluation of Emergency Braking Performance for Electro Mechanical Brake using Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기전동기를 적용한 전기기계식 제동장치의 비상제동 성능평가)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Park, Joon-Hyuk;Kim, Seog-Won;Kim, Sang-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.170-177
    • /
    • 2020
  • This study examined the clamping force control method and the braking performance test results of an electromechanical brake (EMB) using braking test equipment. Most of the studies related to EMBs have been carried out in the automotive field, dealing mainly with the static test results for various control methods. On the other hand, this study performed a dynamic performance evaluation. The three-phase interior permanent magnet synchronous motor (IPMSM) was applied to drive the actuator of the EMB, and the analysis was verified by JMAG(Ver. 18.0), which is finite element method (FEM) software. The current control, speed control, and position control were used for clamping force control of the EMB, and the maximum torque per ampere (MTPA) control was applied to the current controller for efficient control. The EMB's emergency braking deceleration performance was tested in the same way as conventional pneumatic brake systems when the wheel of a train rotates at 110 km/h, 230 km/h, and 300 km/h. The emergency braking time, with the wheel stopped completely at the maximum rotational speed, was approximately 73 seconds. The similarity of the braking time and deceleration pattern was verified through a comparison with the performance test results of the pneumatic brake system applied to the next generation high-speed railway vehicle (HEMU-430X).

Analysis of the Assist Characteristics for Torque of the Ankle Plantarflexion in Elderly Adults Wearing the Ankle-Foot Orthosis (족관절 보조기를 착용한 고령자의 족관절 족저굴곡 토크 보조특성 분석)

  • Kim, Kyung;Kang, Seung-Rok;Piao, Yong-Jun;Jeong, Gu-Young;Kwon, Tae-Kyu
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Ankle-foot orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of ankle muscular activities was developed. In this study, the effectiveness of the system was investigated during plantarflexion motion of ankle joint. To find a effectiveness of the system, the subjects performed maximal voluntary isokinetic plantarflexion contraction on a Biodex-dynamometer. Plantarfexion torque of the ankle joint is assisted by subject's soleus muscle that is generated when ankle joint do plantarflexion motion. We used the muscular stiffness signal of a soleus muscle for feedback control of ankle-foot orthosis as physiological signal. For measurement of this signal, we made the muscular stiffness force sensor. We compared a muscular stiffness force of a soleus muscle between with feedback control and without it and a maximal plantarflexion torque between not wearing a ankle-foot orthosis, without feedback control wearing it and with feedback control wearing it in each ten elderly adults. The experimental result showed that a muscular stiffness force of a soleus muscle with feedback control was reduced and plantarflexion torque of an ankle joint only wearing ankle-foot orthosis was reduced but a plantarflexion torque with feedback control was increased. The amount of a increasing with feedback control is more higher than the amount of a decreasing only wearing it. Therefore, we confirmed the effectiveness of the developed ankle-foot orthosis with feedback control.

Analysis on the Assist Characteristics for the Knee Extension Motion of Lower Limb Orthosis Using Muscular Stiffness Force Feedback (근육 강성도 힘 피드백을 이용한 하지 보조기의 무릎 신전 운동 보조 특성 분석)

  • Kim, K.;Kang, S.R.;Jeong, G.Y.;Joo, S.J.;Kim, N.G.;Kwon, T.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.217-226
    • /
    • 2010
  • The lower limb orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of muscular activities of lower limbs was developed in this study. Compared to other knee extension assistive devices being developed by other researchers, our device is designed especially for the elderly people and intended only for slight assistance so that the subjects can keep their muscular strength. For the effectiveness of system, muscular activities of major muscles in lower limbs during sit-to-stand (STS) and squat motion were measured and analyzed. Subjects were performed the STS and squat motion with and without lower limb orthosis. We made comparison muscular activities between with and without lower limb orthosis. Lower limb orthosis was controlled using muscular stiffness force feedback that is controlled by muscular activities of the measured muscle from force sensor. For analysis of muscular activities, electromyography of the subjects was measured during STS and squat motion, and these were measured using MP 150(BIOPAC Systems, Inc.). Muscles of interest were rectus femoris(RF), vastus lateralis(VL), vastus medialis(VM) and vastus intermedius(VI) muscles in lower limbs of the right side. A biodex dynamometer was used to measure the maximal concentric isokinetic strength of the knee extensors of wearing and not wearing orthosis on right side. The test were performed using the concentric isokinetic mode of test with the velocity set at 60°/s for muscles around the knee joints. The experimental result showed that muscular activities in lower limbs wearing orthosis using muscular stiffness force of a vastus medialis muscle was reduced and knee extension torque of an knee joint wearing lower limb orthosis was increased. With this, we confirmed the effectiveness of the developed lower limb orthosis.