• 제목/요약/키워드: Pliers

검색결과 15건 처리시간 0.021초

부분구조의 상태방정식을 이용한 국부 비선형계의 과도응답해석 (Transient Response Analysis of Locally Nonlinear Structures Using Substructure-Based-State Equations)

  • 김형근;박윤식
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2457-2466
    • /
    • 1993
  • A simple method is presented for determining transient responses of locally nonlinear structures using substructure eigenproperties and Lagrange multiplier technique. Although the method is based upon the mode synthesis formulation procedure, the equations of the combined whole structure are not constructed compared with the conventional methods. Lagrange multi-pliers are used to enforce the conditions of geometric compatibility between the substructure interfaces and they are treated as external forces on each substructure itself. Substructure eigenvalue problem is defined with the substructure interface free of fixed. The transient analysis is based upon the recurrence discrete-time state equations and offers the simplicity of the Euler integration method without requiring small time increment and iterative solution procedure. Numerical examples reveal that the method is very accurated and efficient in calculating transient responses compared with the direct numerical integration method.

Removal of broken syndesmotic screw with minimal bone defects in Korea: a case report

  • Min Gyu Kyung;Chulhee Park
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.265-268
    • /
    • 2023
  • Ankle fractures with syndesmotic injuries often require fixation, where metal screw fixation is a popular method. However, as the patient begins weight-bearing, most syndesmotic screws tend to loosen or break, and removal of such screws has been challenging for the surgeons, as the available techniques require predrilling or trephination and are associated with risks of bone damage. This study presents a case with technical tip for the removal of broken tricortical-fixed non-cannulated syndesmotic screws. It implements the generation of a small cortical window in the medial distal tibia and the use of pliers to engage the screw tip and remove through the medial side. The technique presented in the current study overcomes these limitations and facilitates minimal bone damage and reduced exposure to radiation.

Bonded Linqual Retainer의 최신 제작기술 (A New Technique for Fabrication of Bonded Linqual Retainer)

  • 유진호
    • 대한치과기공학회지
    • /
    • 제20권1호
    • /
    • pp.91-98
    • /
    • 1998
  • Bonded lingual retained are divided into two common types; preformed retainers with attached mash pads, and those that are custom fabricated from standard round ir multi-standed wire. The clinician may encounter problems in the bonding process of both types of retainers because of an inability to accurtely place and temporarily stability the wire in the same position as it was adapted an a guide model. Because of these problems, a new fabrication technique of bonded lingual retainers which increase their accuracy and ease of placement and also increased their tretention was suggested by the author. Using a current model as a guide, this bonded lingual retainer was fabricated from $.028"{\sim}.032"$ standard round wire. The wire was formed with pliers for idel adapation to the lingual surfaces of the involved teeth. Right angle bends were placed in the retainer wire ends and custom "composite" bonding pads were added to the ends of the retainer wire. This bonded lingual retainer with custom "composite" bonding pads is easir to place because of the increased stability and the accuracy of placement is greatly increased. The increased insure that the retainer comforms ideally to the lingual surface of the teeth being retained.

  • PDF

CORDIC을 이용한 디지탈 Quadrature 복조기의 VLSI 구현 (VLSI Implementation of CORDIC-Based Digital Quadrature Demodulator)

  • 남승현;성원용
    • 한국통신학회논문지
    • /
    • 제23권7호
    • /
    • pp.1718-1731
    • /
    • 1998
  • 디지탈 quadrature 복조기는 디지탈 통신 시스템에서 변조된 신호의 정확한 위상 복조를 위해 꼭 필요하다. 기존의 방법들은 주로 DDFS(Direct Digital Frequency Synthsizer)를 이용하여 캐리어를 발생시킨 후에 승산기를 이용하여 복조를 수행하였다. 그리고, DDFS에는 주로 ROM(Read Only Memory)을 사용하였는데, 높은 속도와 정확도를 요구하는 경우 ROM의 속도와 크기가 제한이 될 수있다. 이러한 점을 극복하기 위하여 CORDIC(COordinate Rotation Digital Computer) 알고리듬을 사용하여 주파수 합성은 물론 캐리어 복조까지 수행하는 방식을 제안하였다. 최적의 하드웨어 구현을 위해 제한된 단어길이에 의한 영향을 분석하였으며, 하드웨어 비용면에서 ROM을 사용하는 방법과 비교한 결과 약 1/3 정도로 면적이 줄었다. 제안된 구조를 이요한 전주문형 VLSI 구현 결과를 보인다.

  • PDF

멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구 (A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION)

  • 조일제;손우성
    • 대한치과교정학회지
    • /
    • 제28권2호
    • /
    • pp.329-341
    • /
    • 1998
  • 간염이나 AIDS의 영향으로 멸균에 대한 관심이 높아지고 있으며, 교정 진료실에서도 교정용 플라이어의 멸균이 필요하게 되었다. 제조회사에서는 멸균 과정의 열이 교정용 플라이어에서의 야금학적 변화를 야기하지 않는다고 하지만 교정치과의사들은 가압 증기 멸균기나 대류식 건열 멸균기를 이용하여 반복적으로 멸균을 시행한 경우에 ligature cutter의 날이 쉽게 무디어져서 ligature cutter의 수명이 짧아진다는 것을 임상적 경험으로 알고 있다. 본 연구는 멸균과정이 교정용 플라이어의 물성에 미치는 영향을 알아보기 위하여 시행되었다. 본 연구에 사용된 교정용 플라이어는 멸균 과정을 견딜 수 있도록 개발했다고 주장하는 AEZ, Unitek과 Dentronix ligature cutter이었고, 멸균기는 대류식 건열 멸균기인 Bowmar RHT-1000과 Dentronix DDS-5000와 가압 증기 멸균기 인 Eschmann SES-2000이었다. 멸균하기 전과 200회와 400회 멸균한 후의 ligature cutter의 날 부위의 표면과 파단면의 상태는 주사 저자 현미경으로, 미세 조직은 광학 현미경으로 관찰하고, micro-Vickers와 Rockwell 경도 시험기로 경도를 측정하고, SEM-EDX로 조성 분석을 시행하여 다음과 같은 결론을 얻었다. 1. 주사 전자 현미경을 이용한 교정용 플라이어의 날 부위의 표면과 파단면의 관찰에 의하면 멸균 횟수의 증가에 따라서 표면 조직에서 검은 반점 형태의 부식 생성물의 수와 크기가 증가하는 경향이 있었으며 파단면의 관찰에서도 멸균 횟수의 증가에 따라서 전형적인 취성 파면인 벽개면의 분포율이 증가하는 경향이 있었다. 이러한 부식 현상과 금속 조직의 취성화로 기계적 특성이 저하될 것으로 사료되었다. 2. 광학 현미경을 이용한 미세 조직 사진의 관찰에서도 멸균 횟수의 증가에 따라서 Cr계 탄화물의 수와 크기가 증가하는 경향이 있었다. 이러한 금속 조직의 조대화에 따라서 기계적 특성이 저하된 것으로 생각되었다. 3. 교정용 플라이어의 날 부위의 경도는 멸균 횟수의 증가에 따라서 감소되었는데 경도의 감소는 멸균에 의한 부식생성물과 표면 조직의 변화에 따른 것으로 생각되었다. 4. SEM-EDX를 이용한 조성 분석의 결과에 의하면 AEZ과 Unitek ligature cutter는 Fe-Cr계 stainless steel이었고, Dentronix ligature cutter는 Co-Cr계 합금이었는데, 제조 회사에 따라서 금속의 조성은 달랐지만 멸균 전후의 비교에서는 큰 차이가 없었다. 5. 반복적으로 멸균을 하면서 실제 임상에서 사용한 교정용 플라이어의 날의 표면 조직을 주사 전자 현미경으로 관찰한 결과, 미세 균열을 발견할 수 있었다.

  • PDF