• Title/Summary/Keyword: Pliers

Search Result 15, Processing Time 0.026 seconds

Performance, Wrist Motion and Subjective Rating for Handle Angle of Pliers (손잡이가 휜 Plier의 작업 수행도, 손목 동작과 만족도 평가)

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • This study aims to investigate the effect of handle angles of pliers on performance, wrist motion and subjective rating of satisfaction. An experiment was conducted, in which handle angle of pliers was used as independent variable and 14 subjects participated. Based on the literature survey, plier handles angled at 0$^{\circ}$, 10$^{\circ}$, 20$^{\circ}$, 30$^{\circ}$ and 40$^{\circ}$ were adopted in the experiment. The subjects were instructed to bend iron plates by 90$^{\circ}$ and to cut wires as soon as possible. The results revealed that 1) handle angles of pliers have significant effect on wrist motion and satisfaction(p<0.0001); 2) handle angles of pliers did not affect performance of completing tasks irrespective of types of tasks done in the study; 3) in the initial stage of windup, plier with handle angled at 20$^{\circ}$ produced the least wrist motion of deviation in task of bending iron plates, while plier with handle angled at 40$^{\circ}$ did in task of cutting wires; 4) degree of satisfaction was maximized when handle of pliers was bent by 20$^{\circ}$ in both tasks. On the basis of the results, it is recommended that handle of pliers be bent by 20-30$^{\circ}$ for reducing musculoskeletal disorders related to pliers.

Performance and Preference for Handle Angles of Pliers (손잡이가 휜 Plier의 작업 수행도와 선호도 평가)

  • Kee, Do-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.51-56
    • /
    • 2008
  • This study aims to investigate the effect of handle angles of pliers on performances of task completion time and the number of errors, and subjective ratings of preference. For doing this, an experiment was conducted, where 14 subjects of 11 college-age male and three female students participated. In the experiment, plier handles angled at $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$, and $40^{\circ}$ were used as independent variable, and the task completion time and the number of errors, and subjective ratings of preference as dependent variables. The subjects were instructed to do two tasks of bending an iron plate by $90^{\circ}$ and cutting wires. The results revealed that while the performances of task completion time and the number of errors were not statistically different depending upon the handle angles of pliers, the subjective ratings of preference were significantly different. Based on the results, it is recommended that the pliers with handles bent by $20^{\circ}$ be used in real situations.

Evaluation of Gender Effect in Various Pliers' Grip Spans for Maximum Isometric Grasping Tasks

  • Kong, Yong-Ku;Kim, Dae-Min;Park, Ji-Soo;Lee, Sung-Yong;Choi, Kyeong-Hee;Kim, Kyung Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.553-563
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the effect of gender (male, female) and grip spans (45, 50, 60, 70, 80mm) on total grip strength, resultant force, finger force and subjective discomfort rating. Background: In order to prevent musculoskeletal disorders, studies of hand tools need to be preceded based on grip strength, finger force, and subjective discomfort rating. However, experimental apparatus using tools such as pliers that reflect the actual work place was almost non-existent. Method: Fifty-Two (26 males and 26 females) participants were recruited from the student population. In this study, a pair of revised pliers, which can change grip span from 45 to 80mm was applied to estimate total grip strength, resultant force and individual finger forces. All participants were asked to exert a maximum grip force with three repetitions, and to report the subjective discomfort rating for five grip spans of pliers (45, 50, 60, 70, 80mm). Results: There were significant differences of total grip strength, resultant force, individual finger forces and subjective discomfort rating according to grip span. The lowest total grip strength was obtained from the grip span of 80mm for both genders. For resultant force, the highest resultant force was exerted at grip spans of 50, 60 and 70mm for females and 50 and 60mm for males. The lowest subjective discomfort rating was observed in the 50mm for both genders. Conclusion: Based on the result, 50mm and 60mm grip spans which provide the highest force and lowest discomfort rating might be recommendable for the male and female pliers users. Application: The findings of this study can provide guidelines on designing a hand tool to help to reduce hand-related musculoskeletal disorders and obtain better performance.

Optimal Grip Span of A-type Pliers in a Maximum Gripping Task

  • Kong, Yong-Ku;Jung, Jin Woo;Kim, Sangmin;Jung, Heewoong;Yoo, Hakje;Kim, Dae-Min;Kang, Hyun-Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.511-516
    • /
    • 2013
  • Objective: The objective of this study is designing an optimal hand tool through maximum grip force study accordance to the hand grip span. Background: In order to prevent musculoskeletal diseases, studies on hand tool design are proceeding based on grip strength, finger force, and contribution of individual finger force on total grip strength. However, experimental apparatus using a tool that is actually used in work place was almost non-existent. Method: 19 males were participated in an experiment. Using the load cell inserted real plier, finger force, grip strength, and subjective discomfort rate of both hands (dominant and non-dominant) were measured in 5 different hand grip span(45mm, 50mm, 60mm, 70mm, and 80mm). Results: There was significant difference(p<0.001) of total grip strength, individual finger force and subjective discomfort rating according to various hand grip span(45, 50, 60, 70, and 80mm). Also, statistically significant different(p<0.001) was shown between the dominant hand and non-dominant hand. In addition, individual finger force in maximum grip was in order of middle finger, ring finger, index finger, and little finger. Conclusion: Optimal grip span of pliers that exerting maximum grip strength is 50~60mm. Application: This finding is expected to be used for designing proper pliers.

Application of Quality Function Deployment to Ergonomic Design of a Plier (품질기능전개를 이용한 플라이어의 인간공학적 디자인)

  • Park, Hee-Sok;Lee, Mi-Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.85-90
    • /
    • 2007
  • This study shows a way to develop ergonomic design of a plier through quality function deployment (QFD) approach. User needs for pliers, as well as the engineering characteristics which have influence on the ergonomic quality of pliers were determined from the interviews and questionnaires with various user groups. This information was entered in the house of quality, and the results show that the handle is the most important quality factor. A new model was proposed in which ergonomic and gender aspects were considered. QFD is considered a suitable method especially for the manufacturing and/or design fields where biomechanical or physiological background is not present.

Development of Automatic Operating :System for the Sea Eel Pots Fisheries(I) - Coupling Device for Sea Eel Pot and Separating System - (장어 통발어선의 자동화 조업장치 개발에 관한 연구(I) -통발연결장치.분리장치-)

  • 정용길;김용해;유금범
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.126-131
    • /
    • 2000
  • Capability and performance of the pliers type coupling device for connection of sea eel pots to loop of main line and automatic separating system were investigated at sea as first trial of developing automatic operating system for sea eel pot fishing boat. Obtained main results are as follows. 1. Maximum tensile load of the pliers type coupling device when connection with high twist PP dan-line as a loop of main line was 1603 N, higher than when connection with low twist PP twine 1379 N. 2. A retention ratio of sea eel pots from main line by connecting with coupling device was successful 100% with high performance without any loss in the sea. 3. A ratio of automatic disconnection between sea eel pots using coupling device and loop of main line was perfect 100% without any trouble.

  • PDF

A Study on the Difference of Total Grip Strength and Individual Finger Force between Dominant and Non-dominant Hands in Various Grip Spans of Pliers

  • Kong, Yong-Ku;Park, Hyunjoon;Kim, Dujeong;Lee, Taemoon;Roh, Eunyoung;Lee, Seulki;Zhao, Wenbin;Kim, Dae-Min;Kang, Hyun-Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.503-509
    • /
    • 2013
  • Objective: The purpose of this study is to analyze the individual finger force between dominant hand and non-dominant hand and to investigate an effect of the individual finger on the total grip strength depending on dominant hand and non-dominant hand. Background: Many studies on the ratio of the grip force between dominant hand and non-dominant hand has been researched. While a 10% rule which is a ratio of the grip force between dominant hand and non-dominant hand has been applied in most studies, studies on the rate of the individual finger force between dominant hand and non-dominant hand have been insufficiently researched. Method: The experiment was preceded with 17 subjects (male, mean 25.8 ages). The individual finger force and total grip strength were measured using pliers being able to change the grip span from 45 to 80mm. Results: The difference of total grip strength between dominant hand and non-dominant hand is following 10% rule. However, the difference of individual finger force between dominant hand and non-dominant hand are not same as the difference of total grip strength. Especially in the case of grip span with 50mm, the differences between total grip strength, index finger, middle finger, ring finger, and little finger were $9.87{\pm}14.80%$, $8.95{\pm}37.17%$, $13.71{\pm}28.27%$, $6.77{\pm}24.35%$, $39.29{\pm}42.46%$, respectively, with p=0.018 of statistical significance. Additionally, the results of regression analysis in 50 and 60mm of grip span showed that the difference in ring finger affected the most to the total grip strength; and the effects followed in order of index finger, middle finger, and little finger. Conclusion: Our study suggests that an effect of individual finger and grip span of pliers have to be considered when explaining the difference of the total grip strength between dominant hand and non-dominant hand. Application: This result is expected to be used for designing ergonomic hand tool.

Object recognition of one D.O.F. tools by a backpropagation neural network (신경회로망을 이용한 물체 인식)

  • 김흥봉;남광희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.996-1001
    • /
    • 1991
  • We consider the object recognition of industrial tools which have one degree of freedom. In the case of pliers, the shape varies as the jaw angle varies. Thus, a feature vector made from the boundary image also varies along with the jaw angle. But a pattern recognizer should have the ability of classifying objects without any regards to the angle variation. For a pattern recognizer we have utilized a backpropagation neural net. Feature vectors were made from Fourier descriptors of boundary images by truncating the high frequency components, and they were used as inputs to the neural net for training and recognition. In our experiments, backpropagation neural net outperforms the minimum distance rule which is widely used in the pattern recognition. The performance comparison also made under noisy environments.

  • PDF

Safety in Articles of Food conform to The Product Liability Low Introduction (제조물책임(PL)법 도입에 따른 식품부문의 안전성에 대한 연구)

  • 장정아;서장훈;박명규
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.173-183
    • /
    • 2003
  • The articles of food is very important things to human. Since PL Law came into effect in July of the last year(2002) in Korea, many domestic firms have taken great interests in PL. And the purpose of PL Law is to provide a means for those injured by defective products to receive redress. Additionally, enterprises get to place more importance on the safety of the products, which led to improvement in competitiveness and enhancement in quality. Consequently customers can get better products. So, it aims not only to compensate the injured by defective products but also to act an incentive to maker $s^pliers of food to make their products more safe. Therefore, this study was aiming to analyze the expected risks to articles of food after the enforcement of PL Law, and to establish a defending plan.an.

  • PDF