• Title/Summary/Keyword: Plenum Chamber

Search Result 46, Processing Time 0.025 seconds

An Experimental Study on the Flow characteristics in the Plenum Chamber (플레넘 챔버 내의 유동 특성에 관한 실험적 연구)

  • 정재우;이기형;이창식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.24-31
    • /
    • 1999
  • The MPI engine becomes increasingly popular because it meets two requirements of stringent pollutant emission and the lower fuel consumption. Even though supplies the same amount of fuel to each cylinder , it is hard to precisely control the air-duel ration due to the different amount of air flowing into each cylinder. The uniformity of air-fuel ration in each cylinder is considerably affected by the plenum chamber configuration . This study is focused on experimentally analyzing the flow characteristics within the plenum chamber In the present experiment , steady and valve dynamic state flow tests are performed and the flow field inside the plenum chamber is visualized and measured by utilizing a laser sheet visualization technique and a PTV method. These measured results indicate that the flow structure in the plenum chamber is highly influenced by the plenum chamber configurations, suction flow rates, crank speeds and so on.

  • PDF

Prediction of transmission loss of parallelepiped plenum chambers with liner (흡음재가 부착된 직방형 소음기의 전달 손실 예측)

  • 김회전;이정권;박철민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.383-386
    • /
    • 2003
  • This paper deals with transmission loss of 3-dimensional rectangular plenum lined chamber. There are three kinds of rectangular plenum lined chamber: throughflow type, flow-reversal type, and end-in/side-out type. The combination of above three types of rectangular plenum lined chamber is used for the commercial HVAC system and automobile exhaust system. However, the ambiguity and complexity of sound absorbing material property and 3-dimensional property have impeded research. In this paper, the transmission loss of three kinds of rectangular plenum lined chamber is derived and calculated. The effect of increase of sound absorbing material is also considered. Analytical solution is calculated by using the locally-reacting property of sound absorbing material.

  • PDF

Design of the Plenum Chamber for Reducing Cooling Fan Noise of the Console for Combat Systems in a Naval Vessel (함정의 전투체계 콘솔 냉각 홴 소음저감을 위한 프리넘 챔버 설계)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.6
    • /
    • pp.529-535
    • /
    • 2011
  • Indoor noise is very important related to the morale and fighting power of the crew as well as environmental condition for them in a navel vessel. Especially, the crew members working in CIC (combat information center) and sonar equipment room require much more quiet environment condition. One of the most serious noise source in CIC is the cooling fan noise installed in the console of the combat system. Therefore, in this paper, the design of the plenum chamber is studied to reduce the noise of the fan from these consoles by numerical analysis and experiment.

Design of the Plenum Chamber for Reducing Cooling Fan Noise of the Console for Combat Systems in a Naval Vessel (함정의 전투체계 콘솔 냉각 팬 소음 저감을 위한 프리넘 챔버 설계)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.77-82
    • /
    • 2011
  • Indoor noise is very important related to the morale and fighting power of the crew as well as environmental condition for them in a navel vessel. Especially, the crew members working in CIC(Combat Information Center) and sonar equipment room require much more quiet environment condition in order to increase the performance of their combat system. One of the most serious noise source in CIC is the cooling fan noise installed in the console of the combat system. Therefore, in this paper, the design of the plenum chamber is studied to reduce the noise of the fan from these consoles by numerical analysis.

  • PDF

Design and Analysis of Test Facility for the Experiment of Transpiration Cooling in Hot-flow Condition (고온유동 조건의 분출냉각 실험을 위한 시험장치의 설계 및 해석)

  • Lee, Jungmin;Na, Jaejeong;Kang, Kyoungtaik;Kwon, Minchan;Hwang, Kiyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.46-56
    • /
    • 2013
  • The test facility with hot-air supply system is required to develop transpiration cooling materials and experimentally evaluate its performance. In the study, the facility consists of an arc-plasma generator, plenum chamber suppling cold air, and test section was designed and an internal flow analysis was executed. From CFD results, it was confirmed that the designed plenum chamber thermally safeties and ideally mixes with plasma gas and cold air in the chamber. In addition, validity of design for supplying homogeneous flow to the test section was confirmed by this analysis.

Development of the Silencer for Reducing Noise from the Exhaust Cooling Fan of the TASS Console (예인 음탐기 콘솔의 냉각 배출 홴 소음 저감을 위한 소음기 개발)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been;Son, Yoon-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1139-1146
    • /
    • 2010
  • The indoor noise of the naval vessel is very important related to the optimum environmental conditions for crews as well as the ability of fighting power of antisubmarine. Especially, sonar equipment room is one of the rooms where require to be silent because the informations of the underwater noise are collected and analyzed in there. In this paper, the sound reduction of the TASS console, one of the main noise sources in a sonar equipment room for a typical naval vessel, is described. The noise source of this TASS console is the flowing noise of cooling fan. In order to reduce this kind of noise, the plenum chamber and acoustic elbow were developed. Related to the development of the plenum chamber, the area of the air-outlet and sound absorption of the inner lining were investigated experimentally with the evaluation system of the sound insertion loss. Acoustic elbow was also manufactured and evaluated with the evaluation system of the sound insertion loss. Finally, in order to evaluated the ability of noise reduction of the plenum chamber and acoustic elbow, the indoor noise of the sonar equipment was measured when they were appled to TASS console.

An Experimental Study on the Effects of Intake Manifold Shapes on the Torque Characteristics in a 3-Cylinder LPG Engine (흡기다기관 형상변화가 3기통 LPG엔진의 토크 특성에 끼치는 영향에 관한 실험적 연구)

  • 이지근;이한풍;강신재;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.175-182
    • /
    • 1997
  • The purpose of this study is to investigate the effects of intake manifold shapes to improve the engine performance in a 3-cylinder LPG engine with a closed loop fuel supply system. To know the flow resistance of intake manifolds with shape, the intake negative pressure of each runner in intake manifolds were measured by using the digital pressure meter at each driving condition. And, the engine torque and power have been measured with an engine dynamometer while adjusting the optimal fuel consumption ratio with a solenoid driver. As 속 results form this experiment, the torque characteris- tics were more improved with the plenum chamber(B type intake manifold) than with the banana type(A type intake manifold). The torque characteristics were improved at mid-engine speed(rpm) range as the inner diameter of the intake manifold became smaller. And also the optimum volume among the examined plenum chamber volume was 0.74 times(590cc) the displacement of the test engine.

  • PDF

Prediction of the Transmission Loss of Rectangular Lined Plenum Chamber by the Rayleigh-Ritz Method (Rayleigh-Ritz 방법에 의한 흡음재가 부착된 직방형 소음기의 전달 손실 예측)

  • Kim, Hoi-Jeon;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.869-872
    • /
    • 2005
  • The purpose of this study is on the prediction of the acoustic performance of the lined rectangular plenum chamber which can be used in the HVAC systems. The lined plenum chamber is modeled as a piston driven rectangular tube without mean flow and the acoustic pressure in the lined chamber is obtained by superposing the three dimensional pressure due to each of uniformly and harmonically fluctuating pistons. The arbitrary locations of inlet/outlet ports as well as the acoustic higher order modes generated at the area discontinuities of the port chamber interfaces are taken into consideration. The four-pole parameters can be derived by imposing the proper boundary conditions on each inlet and outlet ports. The lining material on the internal wall is assumed to be a bulk-reacting model. A single weak variation statement which satisfies the fluctuating rigid piston condition and the pressure and displacement continuity condition at the interface between the lining material and the airway was developed. The set of cosine functions were used as the admissible function when applying the Rayleigh-Ritz method. Computed results are compared with those predicted by using the locally-reacting lining material and experimental results, respectively. There are a good agreement shown between the results by the Rayleigh-Ritz method and the experiment results. The derived transfer matrices can be easily combined with other four-pole parameters of different types of mufflers for the calculation of the whole system performance.

  • PDF

An Experimental Study of the Subsonic/Supersonic Steam Ejectors (아음속/초음속 증기 이젝터에 관한 실험적 연구)

  • Kim, Heuy-Dong;Choi, Bo-Gyu;Lee, Jun-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.479-484
    • /
    • 2000
  • For the purpose of a cost effective design of practical subsonic/supersonic ejector systems, an experiment was carried out using a superheated steam as a primary driving flow. The superheated steam jet was produced by several different kinds of subsonic and supersonic nozzles. The secondary flow of atmospheric air inside a plenum chamber was drawn into the primary steam jet. The vacuum performance of the plenum chamber was investigated for a wide range of the ejector operation pressure ratio. The result showed that the static pressure of the mixed flow at the ejector throat is only a function of the ejector operation pressure ratio, regardless of the primary nezzle type employed.

  • PDF