• 제목/요약/키워드: Plenum

검색결과 189건 처리시간 0.024초

액체금속로 핵연료봉의 초음파 산란 해석 (Analysis of ultrasonic scattering from nuclear fuel pins of liquid metal reactor)

  • 주영상
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1998년도 학술발표대회 논문집 제17권 2호
    • /
    • pp.247-250
    • /
    • 1998
  • The scattering of plane ultrasonic waves by the nuclear fuel pin of liquid metal reactor in sodium is studied. According to the internal composition in the cladding tube, the fuel pin has three cross sections, i.e. helium gas plenum, sodium-filled section, and fuel insertion section. The scattering spectra for each section of the fuel pin are different. The circumnavigating ultrasonic waves of each section are analyzed by the resonance scattering method. The whispering gallery wave modes are generated in the sodium-filled plenum section and the fuel rod insertion section with a sodium-gap. The circumferential wave modes are propagated in the cladding tube of the helium gas plenum section. The annular gap between the cladding tube and metal uranium pellet rod affects the scattering spectra. The different propagation characteristics can be utilized for the nondestructive method of detecting the unbonded area and measuring the level of the sodium-filled section of the fuel pin.

  • PDF

함정의 전투체계 콘솔 냉각 홴 소음저감을 위한 프리넘 챔버 설계 (Design of the Plenum Chamber for Reducing Cooling Fan Noise of the Console for Combat Systems in a Naval Vessel)

  • 한형석;박미유;조흥기;김중길;임동빈
    • 한국소음진동공학회논문집
    • /
    • 제21권6호
    • /
    • pp.529-535
    • /
    • 2011
  • Indoor noise is very important related to the morale and fighting power of the crew as well as environmental condition for them in a navel vessel. Especially, the crew members working in CIC (combat information center) and sonar equipment room require much more quiet environment condition. One of the most serious noise source in CIC is the cooling fan noise installed in the console of the combat system. Therefore, in this paper, the design of the plenum chamber is studied to reduce the noise of the fan from these consoles by numerical analysis and experiment.

함정의 전투체계 콘솔 냉각 팬 소음 저감을 위한 프리넘 챔버 설계 (Design of the Plenum Chamber for Reducing Cooling Fan Noise of the Console for Combat Systems in a Naval Vessel)

  • 한형석;박미유;조흥기;김중길;임동빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.77-82
    • /
    • 2011
  • Indoor noise is very important related to the morale and fighting power of the crew as well as environmental condition for them in a navel vessel. Especially, the crew members working in CIC(Combat Information Center) and sonar equipment room require much more quiet environment condition in order to increase the performance of their combat system. One of the most serious noise source in CIC is the cooling fan noise installed in the console of the combat system. Therefore, in this paper, the design of the plenum chamber is studied to reduce the noise of the fan from these consoles by numerical analysis.

  • PDF

LMFBR 출구 공간에 있어서의 난류 혼합에 미치는 부력 효과 (Buoyancy Effects on Turbulent Mixing in the LMFBR Outlet Plenum)

  • Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • 제15권1호
    • /
    • pp.50-56
    • /
    • 1983
  • Scram이 일어난 후 과도 기간 동안 LMFBR 출구공간에 있어서의 유동성층의 영향은 특별한 문제로 제기되고 있다. 이러한 경우에 난류 혼합에 미치는 부력 효과는 설계자에게 중요하다. 난류 유동 방정식에 부력 효과를 갖지 않는 기존 난류 모형의 부력효과를 더하기 위한 연구가 행해졌다. 개발된 부력 난류 유동의 물리적 모형은 SMAC 수치 해석 방법을 통하여 풀어졌다. 개발된 수치 해석 모형이 시험되어졌고, 실험자료와도 비교되었다. 결과는 난류에 대한 부력 효과가 출구공간에서 난류를 강하게 억압하며 성층의 안정도를 상당히 증가시켰다.

  • PDF

A Study on the Coolant Mixing Phenomena in the Reactor Lower Plenum

  • Park, Yong-Seog;Park, Goon-Cherl;Um, Kil-Sup
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.186-195
    • /
    • 1997
  • When asymmetric thermal-hydraulic conditions occur between cold legs, the core inlet temperature will be nonuniform if the coolant is not mixed perfectly in the lower plenum. These uneven core inlet conditions may induce the change in core power distribution. Thus realistic prediction of thermal mixing is important in such abnormal conditions. In this study, reactor internals, which are scaled down as to conserve the flow area ratio, are set up in the model of KORI Unit 1 with the scaling factor of 1/710 by volume and coolant temperatures are measured beneath the lower core plate. Based on experimental results, the ability of COMMIX-1B code to simulate the coolant mixing phenomena in the lower plenum is estimated. The results show that complete mixing never occurs in any conditions and the mixing pattern is characterized according to the plant type.

  • PDF

가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구 (An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling)

  • 김동희;유기형;조동우;서정석;한성필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

Optimization of Blade Profile of a Plenum Fan

  • Wu, Lin;Dou, Hua-Shu;Wei, Yikun;Chen, Yongning;Cao, Wenbin;Ying, Cunlie
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.95-106
    • /
    • 2016
  • A method of optimization design for the blade profile of a centrifugal impeller by controlling velocity distribution is presented, and a plenum fan is successfully designed. This method is based on the inner flow calculation inside the centrifugal impeller, and is related to the distribution of relative velocity. The results show that after optimization, the boundary layer separation on the suction surface has been inhibited and the stability of plenum fan is improved. The flow at the impeller outlet is also studied, and the jet-wake pattern at the impeller outlet is improved obviously by optimization. The calculation result shows that the static pressure and static pressure efficiency can be increased by 15.4% and 21.4% respectively.

선형 레귤레이터 기법을 이용한 다변수 발전설비의 최적제어 (Optimal Control of multivariable Generating System Based on Linear Regulator)

  • 김동화
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제4권4호
    • /
    • pp.61-67
    • /
    • 1990
  • 선형 다변수 원자력 발전설비에 있어서 순환펌프 동력변화, 스로틀 밸브 개도등의 변화에 따라 plenum chamber물온도, core inletdhs도, 연료에 미치는 온도등의 응답이 상호간섭을 받지않고 최적제어 될 수 있는 방법을 선형 레귤레이터 기법을 이용해 고찰하였다. 그 결과 순환펌프의 동력변화, 스로틀 밸브 개도의 외란에 대해 plenum chamberanfdhs도, 노심입구 물온도, 연료 온도 변화 등이 적어 비간섭화 된 안정된 제어가 될 수 있음을 나타냈다.

  • PDF

Thermophysical, Hydrodynamic and Mechanical Aspects of Molten Core Relocation to Lower Plenum

  • Kune Y. Suh;Huh, Chang-Wook
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.707-712
    • /
    • 1997
  • This paper presents the current state of knowledge on molten material relocation into the lower plenum. Consequences of movement of material to the lower head are considered with regardt to the potential for reactor pressure vessel failure from both thermal hydraulic and mechanical standpoints. The models are applied to evaluating various in-vessel retention strategies for the Korean Standard power plant (KSNPP) reactor The results are summarized in terms of thermal response of the reactor vessel from the very relevant severe accident management perspective.

  • PDF

몬주 고속증식로 상부플레넘에서의 열성층에 관한 전산유체역학 해석 (COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF THERMAL STRATIFICATION IN THE UPPER PLENUM OF THE MONJU FAST BREEDER REACTOR)

  • 최석기;이태호
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.41-48
    • /
    • 2012
  • A numerical analysis of thermal stratification in the upper plenum of the MONJU fast breeder reactor was performed. Calculations were performed for a 1/6 simplified model of the MONJU reactor using the commercial code, CFX-13. To better resolve the geometrically complex upper core structure of the MONJU reactor, the porous media approach was adopted for the simulation. First, a steady state solution was obtained and the transient solutions were then obtained for the turbine trip test conducted in December 1995. The time dependent inlet conditions for the mass flow rate and temperature were provided by JAEA. Good agreement with the experimental data was observed for steady state solution. The numerical solution of the transient analysis shows the formation of thermal stratification within the upper plenum of the reactor vessel during the turbine trip test. The temporal variations of temperature were predicted accurately by the present method in the initial rapid coastdown period (~300 seconds). However, transient numerical solutions show a faster thermal mixing than that observed in the experiment after the initial coastdown period. A nearly homogenization of the temperature field in the upper plenum is predicted after about 900 seconds, which is a much shorter-term thermal stratification than the experimental data indicates. This discrepancy is due to the shortcoming of the turbulence models available in the CFX-13 code for a natural convection flow with thermal stratification.