• Title/Summary/Keyword: Plating Condition

Search Result 172, Processing Time 0.022 seconds

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.

A Comparative Analysis of the Level of Occupational Health : Before and After the Subsidiary Program on Health Care Management of Small Scale Industries (영세사업장 보건관리 지원사업 실시 전후의 산업보건수준 비교 분석)

  • Jung, Hye Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.4
    • /
    • pp.58-83
    • /
    • 1995
  • The small scale industries which have less than 30 employees occupy 86.5% of total number of industries in Korea. And though they have higher accident rate and lower environmental condition than big industries, it has been not mandatory to appointing health care manager at factory. So, from 1993, government subsidizes to the health care management of small industries. The purpose of this study is to identify the real feature of health care status in small industries, and to evaluate the level of health care management, before and after the subsidiary program. 65 small plating industries which have been managed by the same health care management support institution in 1993 were selected for study. Of the 65 industries, 3 which have not taken both environmental evaluation and health screening in 1994, and 9 which have closed were excluded from study sample. And the remaining 53 were analyzed by using the results of environmental evaluation and health screening, reported to the Ministry of Labor, before and after the subsidiary program, the analysis was done by the comparison of the two year paired data of the same industry. Over-permissible-limit rate, health screening implementation rate, above grade C rate were calculated and compared. The status of health care management ; 1. Of the sample industries, 96.9% provide protective equipment and 80.0% set up ventilating system. Protective gloves (89.2%) and protective clothing (80.0%) are widely provided, but ear plugs (4.6%) are rarely provided. 21.5% of the protective equipment are well put on, and 40.4% of the ventilating systems function well. 2. In 1993, 35 industries, 53.8% of the sample, checked working environment twice. Over-permissible-limit rates of heavy metal (12.2%), suspended particle (11.1%), noise (5.5%) were high. To put on protective equipment and to set up local ventilating system were pointed out by the examiners. 3. General health screening was done at 63.1% of the sample industries and 35.3% of total workers were examined. Specific health screening was done at 93.8% of the sample industries and 75.4% of workers were examined. 15.5% of workers was provided to be above grade C and to have digestive system disease (43.3%), circulatory disease (18.9%), and hematopoietic disease (14.2%), etc. 4. In 1993, the subsidiary program of health care management was provided in forms of health education, health counseling, and rounding check of working field. And 61.5%, 83.0%, 55.4% of sample industries respectively received it. The average visit per industry was 1.8. Comparisons of the level of occupational health before and after the subsidiary program ; 1. Over-permissible-limit rates of hazardous factors of 1993 and that of 1994 were compared. The rates of suspended particle, noise, organic solvent of 1994 (37.5%, 13.4%, 24.2% respectively) were higher than that of 1993 (25.0%, 6.0%, 6.3% respectively). In the case of acid, there was no difference between the rate of 1993 and that of 1994. Only the rate of heavy metal decreased from 12.9% in 1993 to 3.0% in 1994. 2. General health screening was done at 38.7% of the sample industries in 1993 and at 44.6% in 1994. But the implementation rate of specific health screening decreased from 72.4% in 1993 to 64.6% in 1994. 3. The implementation rate of specific health screening was analyzed by some health factors. The rate of suspended particle increased from 61.8% in 1993 to 91.2% in 1994. But the rates of the others-noise, organic solvent, heavy metal, specific chemical substances-decreased. 4. Above grade C rate in health screening increased from 27.8% in 1993 to 35.5% in 1994. But that of endocrine disorders and pulmonary disease decreased.

  • PDF