• Title/Summary/Keyword: Platform screen door system

Search Result 59, Processing Time 0.028 seconds

Quantitative Risk Reduction Model according to SIL allocated by Risk Graph for Railway Platform Door System (Risk Graph에 의해 할당된 SIL에 따른 철도 승강장 도어 시스템의 정량적 Risk 저감 모델)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.141-148
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. Especially, in case of the SIL allocation method without determining of quantitative tolerable risk, the additional review is needed to check whether it is suitable or not is required. In this study, the quantitative risk reduction model based on the safety integrity allocation results of railway platform screen door system using Risk Graph method has been examined in order to review the suitability of quantitative risk reduction according to allocated safety integrity level.

A Study on The Sign System Following Installation of Screen Doors in Subway Platforms (지하철 승강장 스크린도어 설치에 따른 사인시스템에 관한 연구)

  • Shin, Hong-Jae;Park, Hee-Myeon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1567-1574
    • /
    • 2006
  • To prevent safety accidents such as injury or death from falling by blocking platforms from trains, the Seoul Metropolitan Subway Corp. have gradually installed screen doors in platforms of 115 subway stations in Seoul on lines 1, 2, 3, and 4. Installation in nine areas among those has been completed and screen doors are being operated as a model operation. Traffic signs should be clear for users. The essential functions of signs should be fully investigated from the aspect of user as well as the visual beauty and recognition. Signs should be able to provide users with information regarding location, position, directions, etc. Particularly, safety and convenient signs should be visually and sensually correlated. However, the entire screen doors in platforms installed in line 2 subway in Seoul are used for commercial advertisement, consequently, the functions and roles as public signs are not fulfilled aggravating inconvenience for users. In this study, cases have been studied to investigate requirements for user-oriented sign system in platform and public sign space to fulfill the functions of sign system in platform. Using an anthropometry approach, the study aimed to obtain the space to install the sign system and to systemize necessary and sufficient conditions for user-oriented system for platform in which screen doors have been installed using. The study suggests fundamental information to obtain the space of public sign system on the entire screen door.

  • PDF

A Study of Smoke Exhaust Facility Operation of Subway Platform with Installation of Platform Screen Door (승강장 스크린도어 설치에 따른 배연설비운영에 대한 연구)

  • Rie, Dong-Ho;Ko, Jae-Woong;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.35-40
    • /
    • 2006
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating such an environment as necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Additionally, four different vent modes are made and performances are compared with the original design mode and each other to find better operation of vents at both the platform and the trackway in case of fire. From the result, an vent operational characteristics under the condition of installed PSD is clarified for the effective smoke and heat removal from the platform area compared with non installed PSD.

A Study for the Screen Door Motor System Driving Stiffness of Dynamic Load Condition (스크린 도어 모터 시스템의 동하중 상태 구동강성 검증)

  • Lee, Jung-Hyun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.164-170
    • /
    • 2016
  • The initial urban railway was only required to perform its role as means of transportation. As the time of staying in an underground platform was extended, it has been faced with the issues of environmental improvement as a living space. Therefore, the sliding automatic door, which is the basis of the screen door, is used widely for large distribution stores, hospitals, restaurants, and public offices for customers' convenience and as a convenient method to control access. Therefore, screen doors are required for the purpose of customers' convenience, securing safety, establishing pleasant station buildings, and energy savings. It would be also necessary to develop the optimal design technology for a screen door system through the design of element parts and to ensure reliability. Therefore, this paper calculated, interpreted, and verified the theoretical weight of the composition parts to verify the design drive hardness of the motor for screen doors necessary for the safety of subways.

A study on temperature characteristics of the driving motor of platform screen door. (승강장 스크린도어용 구동모터의 온도특성에 관한 연구)

  • Ohn Jung-Ghun;Kwon Ki Jin;Choi Yung Ha;Shim Jae-Bock
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1278-1284
    • /
    • 2004
  • Platform screen dorr (PSD) is equipment composed of screens and doors on the platform of subways or light trains, separating the platform from the railroad. The equipment is opened and closed in connection to the doors of carriages. In order to operate the system safely, it is important to understand the characteristics of key parts. There are many parts and environmental factors such as voltage, current and temperature change but the present study measured the change rate of torque and energy changes according to the temperature of the driving motor and analyzed the characteristics of the changes and examined the features of a motor required for stable PDS and the conformability of control programs.

  • PDF

Study for Interface Between EMU and PSD in Metro (도시철도의 전동차와 PSD 인터페이스 고찰)

  • Seon, Jong-Min;Jo, Eun-Je;Yang, Dong-Seok;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1397-1404
    • /
    • 2011
  • Metro serves more than a basic function of transporting passengers between short distances but became a crucial part of civic culture due to the fact that citizens demand various facilities for better life style. Therefore, domestic metro cuts off train noise and air dust, provides pleasant platform surroundings by offering effective HVAC, and establishes PSD (Platform Screen Door) system to prevent falls into train tracks. To control and interlock EMU Door and PSD to avoid passenger complaint and revenue service obstructions, stability and reliability of on-board & wayside equipment are required foremost and each line needs to build optimum interface between on-board & wayside equipment. To control PSD, we would like to introduce examples of Busan Metro(BTC : Busan Transportation Corporation) which already utilizes interface between on-board & wayside equipment in various ways and consider optimum interface between on-board & wayside equipment in future PSD system.

  • PDF

A Study on PSD System optimization from manual mode (수동 Mode에서 PSD System 최적화 연구)

  • Son Young-Jin;Min Kyung-Yun;Lee Kang-Won;Bang Yeun-Gun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.162-167
    • /
    • 2004
  • The ascent and descent market screen door (PSD-Platform Screen Door) between the electromotive car which is in the process of operating from the subway ascent and descent market and the passenger it is an immediacy and crisis as the system which it intercepts currently the inside and outside of the country of course signal system automatic operation signal system (ATO) establishment is operated from the segment. Manual operation signal system (the ATS and the ATC) almost it is a condition which is wholly lacking from the segment. This year from second half of the year 2 line manual operation signal system (ATS). It established the shutting tightly elder brother and the railing elder brother in PSD system in segment 12 reverses and the death accident due to the passenger hurt accident which occurs from the subway. It prevented an energy curtailment in the same time when it raises air cooling efficiency, It gathered it restricted the underground space which is comfortable in the use citizen and and and service it did interface the electromotive car and PSD entrance and exit literature course from the manual operation segment to sleep technically optimizationt. It researched a minute dust diffusion.

  • PDF

A Case Study for SMRT Train Open Doors Control System (도시철도의 열차출입문제어에 관한 연구)

  • Won, Yu-Duck;Shim, Won-Sub
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.941-946
    • /
    • 2006
  • It followed in system development and SMRT(Seoul Metropolitan Rapid Transit Co)System reached to an automatic train operation(ATO) and driverless operation(DLM) from the manual operation due to the train driver. The train like the general bus or the car vehicle was not serial riding in a car and the Parallel concept which the numerous passenger rides in a car simultaneously occur frequently the charge of the train driver unmanned bitterly from existing manual handling was a possibility of doing, train open door control(ODM) which bites also ATO, it handles it minimized. Like this ATO/DLM, the control system which bites being a Wayside to Train communication for immediacy, it is a system of the Vital concept the immediacy of the citizen Data evil the radio information transmission and the train of the interface which is accurate from unmanned operation and, will decipher, will accomplish it will guarantee. It respects the passenger accident prevention and an air question environment improvement from subway platform and phul leys the screen door of Platform(PSD) with the fire tube frost it refers and part it treats and to sleep it does, ODM which bites is accuracy and immediacy of altitude and when seeing from the viewpoint which demands the trust of altitude, ODM system the trust of car incest interface in the equipment construction which is safe and the comparative analysis back of the system analysis against the control which bites and case study and other subway system it leads from the research which it sees and signal - train in base grudge to sleep it contributes it does.

  • PDF

The Effect of Platform Screen Doors on PM10 Levels in a Subway Station and a Trial to Reduce PM10 in Tunnels

  • Son, Youn-Suk;Salama, Amgad;Jeong, Hye-Seon;Kim, Suhyang;Jeong, Jin-Ho;Lee, Jaihyo;SunWoo, Young;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.38-47
    • /
    • 2013
  • $PM_{10}$ concentrations were measured at four monitoring sites at the Daechaung station of the Seoul subway. The four locations included two tunnels, a platform, and a waiting room. The outside site of the subway was also monitored for comparison purposes. In addition, the effect of the platform screen doors (PSDs) recently installed to isolate the $PM_{10}$ in a platform from a tunnel were evaluated, and a comparison between $PM_{10}$ levels during rush and non-rush hours was performed. It was observed that $PM_{10}$ levels in the tunnels were generally higher than those in the other locations. This might be associated with the generation of $PM_{10}$ within the tunnel due to the train braking and wear of the subway lines with the motion of the trains, which promotes the mixing and suspension of particulate matter. During this tunnel study, it was observed that the particle size of $PM_{10}$ ranged from 1.8 to 5.6 ${\mu}m$. It was revealed that the $PM_{10}$ levels in the tunnels were significantly increased by the PSDs, while those in the platform and waiting room decreased. As a result, in order to estimate the effect of ventilation system on $PM_{10}$ levels in the tunnels, fans with inverters were operated. It was found that the concentration of $PM_{10}$ was below 150 ${\mu}g/m^3$ when the air flow rate into a tunnel was approximately 210,000-216,000 CMH.

A study train door open-close perception control System using ultrasonic sensor (초음파 센서를 이용한 전동차 도어 개폐 감지 장치에 관한 연구)

  • Lee, Jong-Seong;Lee, Hi-Sung;Lee, Hae-Cheol;Kim, Sung-Ryul;Cho, Hyun-Sang
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1681-1688
    • /
    • 2011
  • The platform screen door open-close mechanisms at today's subway are divided by "Radio Frequency method" and "Method at entrance perception sensor". In the case of "method at entrance perception sensor", there happen a lot of occasions of malfunctioning that may cause problems in terms of timeliness, swiftness and reliability of train operation and even ends up to train operation stop since the perceiving process is complicated and it is prone to have dust on lenses, position alteration by train vibration, and less reflection light in the case of new train. In this study, we find how to minimize possible problems in terms of maintenance during train operation period, and seek its alternatives in order not only to have no malfunction in perception but also to cause no disturbance in train operation through dealing organically when perceiving door open-close to minimize delay time.

  • PDF