• 제목/요약/키워드: Plate-Shaped

검색결과 478건 처리시간 0.022초

Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

  • Byun, Chun Sung;Park, Il Hwan;Hwang, Wan Jin;Lee, Yeiwon;Cho, Hyun Min
    • Journal of Chest Surgery
    • /
    • 제49권5호
    • /
    • pp.361-365
    • /
    • 2016
  • Background: Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. Methods: We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. Results: Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. Conclusion: Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.

Torsional rigidity of arbitrarily shaped composite sections by hybrid finite element approach

  • Darllmaz, Kutlu;Orakdogen, Engin;Girgin, Konuralp;Kucukarslan, Semih
    • Steel and Composite Structures
    • /
    • 제7권3호
    • /
    • pp.241-251
    • /
    • 2007
  • The purpose of this study is to calculate the torsional rigidity of arbitrarily shaped composite sections on the basis of hybrid finite element approach. An analogy is used between the torsion problem and deformation of a plate which exhibits only shear behavior. In the analysis a simple hybrid finite element based on Hellinger-Reissner functional is presented and a set of numerical examples are performed to demonstrate and asses the performance of the developed element in practical applications.

Use of a Y-Shaped Plate for Intermaxillary Fixation

  • Kim, Tae Hoon;Yang, Il Hyung;Minn, Kyung Won;Jin, Ung Sik
    • 대한두개안면성형외과학회지
    • /
    • 제16권2호
    • /
    • pp.96-98
    • /
    • 2015
  • Maxillomandibular fractures usually require intermaxillary fixation as a means to immobilize and stabilize the fracture and to re-establish proper occlusion. Arch bars or intermaxillary fixation screws cannot be used for edentulous patients or for patients who have poor dental health. Here, we present a case of repeated intermaxillary fixation failure in a patient weak alveolar rigidity secondary to multiple dental implants. Because single-point fixation screws were not strong enough to maintain proper occlusion, we have used Y-shaped plates to provide more rigid anchoring points for the intermaxillary wires. We suggest that this method should be considered for patients in whom conventional fixation methods are inappropriate or have failed.

임의 형태의 개구에 의한 평행평판 도파관으로의 전자기적 결합 문제 해석을 위한 적분 방정식 방법 (Integral equation formulation for electromagnetic coupling through an arbitrarily shaped aperture into a parallel-plate waveguide)

  • 이영순;이창원;조영기;손현
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.25-35
    • /
    • 1995
  • An analysis method of electromagnetic coupling through an arbitrarily shaped aperture on the upper wall of parallel-plate waveguide, when excited by an electromagnetic plane wave from outside, is considered. The mixed-potential integral equation, in which Green's functions are expressed in a computationally efficient closed form by using the Prony's method and the Sommerfeld identity, is formulated. Expanding the unknown equivalent magnetic surface current in terms of two-dimensional rooftop-type basis functions and choosing razor testing, the integral equation is reduced to a linear algebraic equation, which is solved. The results are compared with the previous results. Fairly good agreements between them are observed.

  • PDF

슬림 AU 합성보의 전단성능에 관한 실험연구 (Experimental Study on the Shear Capacity of Slim AU Composite Beam)

  • 이미향;오명호;김영호;정석창;김명한
    • 한국공간구조학회논문집
    • /
    • 제17권3호
    • /
    • pp.99-105
    • /
    • 2017
  • The SLIM AU composite beam consists of U-shaped steel plate, A-shaped steel cap and infilled concrete. The bottom steel plate acts as tension bars, and the top steel cap takes roles of shear connector and compression bars in the conventional reinforced concrete section. In this paper the shear strength of this composite beam with closed steel section has been evaluated through the concentrated loading shear experiments. Test results under the symmetrical and asymmetrical loading conditions were compared with the predicted values based on the KBC 2016. The composite beam showed the greater shear strength capacities than those of the theoretical evaluation.

매립지반의 팽이말뚝 평판재하시험 사례 연구 (Case Study Top-Base Foundation Static Loading Test in Reclaimed Land)

  • 신은철;김성환;이애영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.721-728
    • /
    • 2008
  • Top-Base Method is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and the effect of restraining settlement when the bearing capacity of the ground is not enough. Top-shaped cone concrete foundations are installed in graveled laid over soft ground. The principle of the basic method is to maximize effect of dispersing the overburden pressure by increasing the contact area of the top-shaped cone. Therefore, the bearing capacity is increased and the settlement is decreased by the embedded resistance of pile part in the ground. In this paper, the plate bearing test was conducted to evaluate the feasibility of Top-Base foundation. Based on the test results, the coefficient of subgrade reaction, elastic modulus, and settlement of foundation on reclaimed land was derived.

  • PDF

좁은 평행평판전극 사이의 ER유체 유동의 가시화 (The Flow Visualization of ER Fluid Between Two Parallel-Plate Electrodes Separated by Small Distance)

  • 박명관;이은준;오시마 슈조;야마네 류이치로
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.801-810
    • /
    • 1999
  • The purpose of present research was to get characteristics and basic knowledges of electrorheological(ER) suspension. To observe behaviors of the ER suspensions. transparent conductive plates were used to visualize the flow of ER suspensions between two parallel plate electrodes. The influence of flowing speed and intensity of electric field on the ER fluid were examined in circle-shaped electric field, and it takes several hundred milliseconds that suspensions in flow cluster. The present study also conducts a numerical analysis adopting the Bingham model. It is found that simple Bingham model can not property describe the flow behavior in the parallel plates.

대향류 마이크로 채널 판형 열교환기의 열전달 특성 실험적 연구 (An Experimental Study on Heat transfer Characteristics in Micro Plate Heat Exchangers with Counter flow of Microchannel)

  • 서장원;김윤호;문정은;이규정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.229-234
    • /
    • 2007
  • Microscale heat transfer and microfluidics have become increasingly important to overcome some very complex engineering challenges. The use of very small passages to gain heat transfer enhancement is a well documented method for achieving high heat flux dissipation. As the passage size is decreased, the heat transfer performance increases but the pressure drop increases sharply when the passage size is reduced. In this study, the performance evaluation of micro plated heat exchangers under the counter flows with straight, V-shaped and Y-shaped channel are carried out.

  • PDF

Vibration Power Flow Analysis of Submarine-shaped Structures using Developed Software

  • Seo, Seong-Hoon;Hong, Suk-Yoon
    • Journal of Ship and Ocean Technology
    • /
    • 제6권2호
    • /
    • pp.1-11
    • /
    • 2002
  • For the analysis of vibrational energy density and intensity of partitioned complex system structures in medium-to-high frequency ranges, A software based on the Power Flow Analysis(PFA) has been developed for the plate elements. The flexural, longitudinal and shear waves in plates are formulated and the joint element equations for multi-coupled plates are fully developed. Also, the wave transmission approach has been introduced to cover the energy transmission and reflection at the joint plate elements. To confirm the validity of the developed PFA software, the submarine-shaped complex structures are used for the analysis of vibration intensity and energy density.

Morphology of Lithothamnion japonicum (Hapalidiaceae, Rhodophyta): A New Record of Coralline Species from Korea

  • Jeong, So Young;Won, Boo Yeon;Cho, Tae Oh
    • 환경생물
    • /
    • 제36권3호
    • /
    • pp.319-328
    • /
    • 2018
  • The morphology, anatomy and reproduction (tetra/bisporic and male) of Lithothamnion japonicum Foslie was studied, using holotype material and materials collected from Korea. Lithothamnion japonicum is characterized based on the presence of encrusting, warty to fruticose thallus, branched or unbranched short and cylindrical protuberances, conical shaped spermatangial conceptacles, branched (dendroid) spermatangial systems formed on floor, walls, and roof of conceptacle chamber, cylindrical shaped spermatangial conceptacle canal, 9-10 cell layered spermatangial conceptacle roof, raised tetra/bisporangial conceptacles without rims, flattened tetra/bisporangial conceptacle pore plate, 16-50 pores on each pore plate, 6-8 rosette cells surrounded by each pore, pore canal lining filaments composed of tetra/bisporangial conceptacle roof, and buried senescent tetra/bisporangial conceptacles completely infilled with relatively large and irregularly arranged calcified sterile cells. In this study, we report a new record of Lithothamnion japonicum from Korean coasts.