• 제목/요약/키워드: Plate in Water

검색결과 1,491건 처리시간 0.028초

병렬판상전극의 수조모델 시뮬레이션 해석 (Analysis for Water tank model simulation of parallel plate electrodes)

  • 고희석;김성삼;이충식;최종규;류희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.280-282
    • /
    • 2003
  • In this paper we tried to analyze through the water tank model to solve these kinds of problems about the square plate earth electrode using general facilities with being compared with the theory formula announced before. The square plate earth electrode that haven't investigated so far is analyzed by being based on laid rod electrode. And the each kind of calculation model was investigated with the experiment of water tank. An experiment of the vertical square Plate electrode about laying depth in the center of the surface of the water has already done with the practical models that have different forms of electrodes.

  • PDF

먹는 샘물의 개봉 후 음용과정에서의 보관 조건에 따른 미생물학적 수질 변화 (Change of Microbiological Quality according to Various Storage Conditions in the Drinking Process of Bottled Mineral Water)

  • 배경선;김지혜;장준형;김정명;이원석;정현미;박상정
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.499-508
    • /
    • 2017
  • Objective: This study was conducted to investigate changes in microbiological quality according to various storage conditions in the drinking process of bottled mineral water. Methods: Heterotrophic plate counts ($21^{\circ}C$ and $36^{\circ}C$) and pathogenic indicators (total coliforms, fecal Streptococcus, Pseudomonas aeruginosa, Clostridium perfringens, Salmonella, and Shigella) were analyzed in commercial bottled mineral water stored under different conditions ($4^{\circ}C$, $20-25^{\circ}C$, $36^{\circ}C$) after injecting saliva. The heterotrophic plate counts were analyzed twice per day for the first week and once per day for the three weeks after. Pathogenic indicators were analyzed at the beginning and end (initial and final). Results: The results of the microbiological quality of the bottled mineral water in contact with saliva showed that heterotrophic plate counts ($21^{\circ}C$) had a tendency to be sustained or decrease slightly after 10 days. Heterotrophic plate counts ($36^{\circ}C$) had a high population in the initial samples and gradually decreased at $4^{\circ}C$ storage, but it remained constantly high in storage at $20-25^{\circ}C$ and $36^{\circ}C$. In the general drinking condition, the population was slightly higher than the control, but the overall trend was similar. Conclusions: As a result of the microbiological quality of mineral bottled water in contact with saliva during the process of drinking, heterotrophic plate counts ($21^{\circ}C$ and $36^{\circ}C$) showed a high population compared to the control, which was only opened and not in contact with saliva. In some samples, pathogenic indicators were also detected. Therefore, it is desirable to consume bottled mineral water as soon as possible after opening.

경사각을 갖는 적층판식 유수분리기의 유수분리 효율에 관한 연구 (A Study on the Oil/Water Separation Efficiency of Laminated Plate Type Oily water Separator with Inclined Angle)

  • 한원희;김준효;최민선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.365-374
    • /
    • 2001
  • Its a tendency to strengthen related international was as the importance on marine oil pollution recently becomes the issue. According to the regulation of IMO, oil discharge from ships is allowed under 15PPM only and oil filtering equipment is essential. Oily water separator of laminated plate type which is one of gravity type separator can be use as assistant equipment for the oil filtering system to meet the present IMO standard, because it fits well to process large amount of rich oil with high specific gravity. The purpose of this paper is to investigate an efficiency of oil/water separation with the characteristics of laminated plate arrangement. The analyse of oil contents for oil-water mixture were carried out in order to find an efficiency of oil/water separation and an experimental study was simultaneously carried out to investigate internal flow characteristics of separator by visualization method and PIV(Particle Image Velocimetry) measurement at three spaces of plates for 5, 10 and 15 mm with variation of inlet flow rates of $0.25m^3$/h and $0.5m^3$/h. The experimental results showed that the space of the plates acts a significant role in the separating process.

  • PDF

A study on the simulation of water cooling process for the prediction of plate deformation due to line heating

  • Nomoto, Toshiharu;Jang, Chang-Doo;Ha, Yun-Sok;Lee, Hae-Woo;Ko, Dae-Eun
    • International Journal of Ocean System Engineering
    • /
    • 제1권1호
    • /
    • pp.46-51
    • /
    • 2011
  • In a line heating process for hull forming, the phase of the steel transforms from austenite to martensite, bainite, ferrite, or pearlite depending on the actual speed of cooling following line heating. In order to simulate the water cooling process widely used in shipyards, a heat transfer analysis on the effects of impinging water jet, film boiling, and radiation was performed. From the above simulation it was possible to obtain the actual speed of cooling and volume percentage of each phase in the inherent strain region of a line heated steel plate. Based on the material properties calculated from the volume percentage of each phase, it should be possible to predict the plate deformations due to line heating with better precision. Compared to the line heating experimental results, the simulated water cooling process method was verified to improve the predictability of the plate deformation due to line heating.

수중 스트리머 방전용 플라즈마 반응기 구조에서 수소발생 특성 (The Characteristic of Hydrogen Generation on the Structure of Plasma Reactor Using the Streamer Discharge in the Water)

  • 박재윤;김종석
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.37-42
    • /
    • 2006
  • 본 논문에서는$CO_2$를 발생시키지 않고 물로부터 직접 수소를 제조하기 위하여 비열플라즈마를 이용하였다. 다중침-평판형(Multineedle-plate electrode geometry reacto: MPER)과 단일침-평판형(Needle-plate electrode geometry reactor: NPER) 두종류의 수소제조 반응기를 설계 제작하여 수소 발생에 미치는 영향에 대하여 실험하였다. 수소발생을 높이기 위해서는 강한 아크성 스트리머 방전 발생과 효과적인 수표면 방전을 위한 수표면 조건을 고려해야만 된다.

경사파중 수중평판에 의한 파랑변형 (Wave Diffractions by Submerged Flat Plate in oblique Waves)

  • 조일형;김현주
    • 한국항만학회지
    • /
    • 제10권1호
    • /
    • pp.53-61
    • /
    • 1996
  • This paper describes the effect of wave control using submerged flat plate by the numerical calculation and the hydraulic model test. The boundary element method is used to develop a numerical solution for the flow field caused by monochromatic oblique waves incident upon an infinitely long, sumerged flat plate situated in arbitrary water depth. The effect of wave blocking is examined according to the change of length, submerged depth of flat plate and incident angles. Numerical results show that longer length, shallower submergence of flat plate and larger incident angles enhance the effect of wave blocking. To validate numerical analysis method, hydraulic model test was conducted in 2-D wave flume with 60 cm metal sheet. Reflected waves are extracted from water surface elevation in front of the location of a submerged plate by least square method with 3 wave gages. From comparing experimental results with numerical results, efficiency of numerical analysis method by this study could be confirmed well within wide ranges of wave frequencies.

  • PDF

원자력발전소 기기냉각수계통의 판형열교환기 적용성 (Applicability of Plate Heat Exchanger to Plant Cooling Water Systems in Pressure Water Reactor)

  • 임혁순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.505-510
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. Due to the increased electric power, In Nuclear Power plant huge quantities of heat are generated in the thermo-dynamic process used for producing electrical energy. So, There is considerationly additional cooling, Heat transfer area and increased cooling water of Heat Exchanger which take care of the different smaller cooling duties within the nuclear power plant. We review applying to PRE instead of Shell-and-Tube Heat exchanger. In this paper, we describe the major design features of PRE, Comparison between a PHE and a Shell-and-Tube Heat Exchanger, and then Applicability of Plate Heat Exchanger in Nuclear Power Plant Component Cooling water systems.

  • PDF

수중 하베스트형 빙축열시스템의 축방냉 특성 실험 (Experiment on the Charge and Discharge of Thermal Energy for Under-Water Harvest-Type Ice Storage System)

  • 김재돌
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.11-17
    • /
    • 2002
  • This paper is concerned with the development of a new method for making, separating ice and storage floated ice by installing an evaporation plate at under-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating an ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. Developed new harvest-type method shows good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, however these components are not necessary in a new method. In this study ice storage systems are experimentally investigated to study the charge and discharge of thermal energy. The results show the applicable possibility and performance enhancement of a new type.

암모니아/물 흡수식 냉동기의 판형 재생기의 수치해석 (Numerical Analysis of a Plate Type Generator for Ammonia/Water Absorption Refrigerators)

  • 지제환;정은수;정시영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.304-310
    • /
    • 2001
  • A numerical model which simulates the heat and mass transfer processes within a counter-current plate type generator for ammonia/water absorption refrigerators was developed. Ammonia/water solution flows downward under gravity and ammonia/water vapor generated by flow boiling flows upward. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phase were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the generator length, the wall temperature and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

인천지역 대기 환경 중 배양성 세균의 특성 (Characterization of Culturable Bacteria in the Atmospheric Environment in Incheon, Korea)

  • 이시원;박수정;김지혜;민병대;정현미;박상정
    • 한국환경보건학회지
    • /
    • 제42권2호
    • /
    • pp.126-132
    • /
    • 2016
  • Objectives: This study aims to provide basic data regarding the bacterial total plate count in the atmospheric environment for related studies. Methods: Total plate count and the identification of culturable bacteria in the atmospheric environment in Incheon took place in 2015 using periodic survey. Correlationship analysis was performed between the number of culturable bacteria and environmental elements. In addition, an estimation of novel bacterial species was undertaken using the similarities and phylogenetic tree based on the 16S rRNA gene. Results: The total plate count of culturable bacteria was on average $176CFU/m^3$, and did not exceed $610CFU/m^3$ in the atmospheric environment. Periodic monthly measuring of total plate count was highest in June at $293CFU/m^3$, while the lowest was in July at $125CFU/m^3$. Furthermore, as a result of the identification of culturable bacteria, the genera Arthrobacter and Kocuria were dominant, while novel bacterial taxa that belong to the genera Chryseobacterium and Herbiconiux were separated. Conclusion: The total number of culturable bacteria from the atmospheric environment in Korea is on average $176CFU/m^3$. In addition, the genera Arthrobacter and Kocuria dominate. The presence of novel bacterial taxa are expected in the atmospheric environment, such as belonging to the genera Chryseobacterium and Herbiconiux.