• Title/Summary/Keyword: Plate and screw removal

Search Result 14, Processing Time 0.029 seconds

Plate and Screw Removal after Orthognathic Surgery, under Intravenous Sedation with Dexmedetomidine and Pethidine (Dexmedetomidine과 Pethidine을 이용한 정맥내 진정하에 시행된 악교정수술 후 금속나사제거)

  • Kang, Hee-Jea;Kim, Jong-Ryoul;Kim, Si-Yeob;Choi, Tea-Sung;Chang, Kwang-Uk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.260-266
    • /
    • 2012
  • Purpose: The purpose of this study is to identify the changes of a physiologic nature and the sedative parameters associated with dexmedetomidine and pethidine, in patients undergoing plate and screw removal surgery, after orthognathic surgery. Methods: Twenty-three patients were sedated with dexmedetomidine and pethidine during plate and screw removal, after orthognathic surgery. An initial loading dose of dexmedetomidine ($1.0{\mu}g/kg$ infused over 10 minutes) was followed by a maintenance dose ($1.0{\mu}g/kg/hr$). Systolic blood pressure, diastolic blood pressure, mean arterial pressure, oxygen saturation, and heart rate were monitored. Perioperative amnesia and anxiety were recorded. Results: Significant changes were found in the blood pressure and heart rate (Freidman test, P<0.05), but not in oxygen saturation (Freidman test, P>0.05). Amnesia during local injection was observed in eight patients (34.8%). Compared with the preoperative anxiety score, the intraoperative anxiety score was decreased. Conclusion: In this study, we found cardiovascular and respiratory stability in intravenous sedation using dexmedetomidine with pethidine, in plate and screw removal, after orthognathic surgery. Furthemore, intravenous sedation using dexmedetomidine with pethidine shows adequate analgesic and sedative effects.

Long-term Stability after Reduction of Mandible Fracture by Keyhole Plate: Evaluation at the Time of Plate Removal

  • Cheon, Kyeong-Jun;Cho, Seoung-Won;Jang, Won-Seok;Kim, Ju-Won;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.6.1-6.6
    • /
    • 2020
  • Background: Various types of miniplates have been developed and used for the reduction of facial bone fractures. We introduced Yang's Keyhole (YK) plate, and reported on its short-term stability. The purpose of this study was to evaluate the long-term stability of the YK plate, as a follow-up study, by examining the patients who had used the YK plate among the patients with the reduction of mandible fractures and who visited for plate removal. Methods: We reviewed the medical records of 16 patients who underwent mandibular fracture fixation using a YK plate (group I) and 17 patients who underwent mandibular fracture fixation using a conventional plate (group II). Assessment was then made on malunion, occlusal stability, discomfort during the application, and clinical symptoms. Results: From January 2015 to December 2017, a total of 36 patients underwent mandibular fracture surgery using a YK plate. A total of 16 patients received plate removal. Among them, 15 were male and 1 female. The average age was 26 years. The applied surgical sites were the 12 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of YK plate was an average of 335 days. During the same period, 45 people underwent surgery on the conventional plate. A total of 17 patients received plate removal. Among them, 15 were male and 2 females. The average age was 36 years. The applied surgical sites were the 8 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of the conventional plate was an average of 349 days. No malocclusion occurred at the time of removal, and occlusion was stable. No patient complained of joint disease or discomfort. Conclusion: The YK plate system, in which the screw was first inserted and the plate was applied, for clinical convenience did not cause any particular problem and no significant difference from the conventional plate.

Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures (생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료)

  • Kwon, Duck-Joo;Lee, Yong-Beom;Shin, Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF

Reconstruction plates used in the surgery for mandibular discontinuity defect

  • Seol, Guk-Jin;Jeon, Eun-Gyu;Lee, Jong-Sung;Choi, So-Young;Kim, Jin-Wook;Kwon, Tae-Geon;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.266-271
    • /
    • 2014
  • Objectives: The purpose of this study was to analyze the survival rate of reconstruction plates that were used to correct mandibular discontinuity defects. Materials and Methods: We analyzed clinical and radiological data of 36 patients. Only discontinuous mandibular defect cases were included in the study. Reconstruction plate survival rate was analyzed according to age, gender, location of defect, defect size, and whether the patient underwent a bone graft procedure, coronoidectomy, and/or postoperative radiation therapy (RT). Results: Plate-related complications developed in 8 patients, 7 of which underwent plate removal. No significant differences were found in plate survival rate according to age, gender, location of defect, defect size, or whether a bone graft procedure was performed. However, there were differences in the plate survival rate that depended on whether the patient underwent coronoidectomy or postoperative RT. In the early stages ($9.25{\pm}5.10months$), plate fracture was the most common complication, but in the later stages ($35.75{\pm}17.00months$), screw loosening was the most common complication. Conclusion: It is important to establish the time-related risk of complications such as plate fracture or screw loosening. Coronoidectomy should be considered in most cases to prevent complications. Postoperative RT can affect the survival rate and hazard rate after a reconstruction plate is fitted.

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.

Mycotic Abdominal Pseudoaneurysm due to Psoas Abscess after Spinal Fusion

  • Ryu, Dae Woong;Lee, Sam Youn;Lee, Mi Kyung
    • Journal of Chest Surgery
    • /
    • v.48 no.6
    • /
    • pp.443-446
    • /
    • 2015
  • A 36-year-old man, who had undergone thoracoscopic anterior spinal fusion using the plate system and posterior screw fusion three months previously, presented to our hospital with left flank pain and fever. Computed tomography indicated the presence of a psoas muscle abscess. However, after two days of percutaneous catheter drainage, a mycotic abdominal aortic pseudoaneurysm was detected via computed tomography. We performed in situ revascularization using a prosthetic graft with omental wrapping. Methicillin-resistant Staphylococcus aureus was identified on blood and pus culture, and systemic vancomycin was administered for one month. Although the abscess recurred, it was successfully treated with percutaneous catheter drainage and systemic vancomycin administration for three months, without the need for instrumentation removal. The patient remained asymptomatic throughout two years of follow-up.

New Fixation Method Using Two Crossing Screws and Locking Plate for Cubitus Varus Deformity in Young Adult Elbow: Case Report

  • Kim, Byoung Jin;Seol, Jong Hwan;Kim, Myung Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • Many types of osteotomy have been proposed for the treatment of cubitus varus deformity of the elbow, and various methods for fixation of the osteotomy site have also been described. However, no method has been perfect. We treated two cases of cubitus varus elbow deformity with step-cut osteotomy using a new fixation method with two crossing screws and an anatomically designed locking plate. Active assisted elbow range of motion (ROM) exercise was permitted at postoperative 3 days, after removal of the drainage. Preoperative and postoperative humerus-elbow-wrist angles and ranges of motion of the two patients were compared. At 3 months followup, each patient had recovered the preoperative elbow ROM, and achieved the complete bony union of the osteotomy site and proper correction of the cubitus varus deformity. In addition, the appropriate remodeling of the lateral bony protrusion was observed. Therefore, we introduce a new fixation method for achievement of stable fixation allowing immediate postoperative elbow motion after corrective osteotomy for cubitus varus deformity in young adults.

An effect of immediate orthodontic force on palatal endosseous appliance$(C-Palatal\;Plate^{TM})$ in beagle Dog (성견 구개부 골내고정원 장치에 가해진 즉시 교정력이 주위조직에 미치는 영향)

  • Kim, Su-Jung;Lee, Young-Jun;Chug, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.91-102
    • /
    • 2003
  • This study was performed to investigate the effect of immediate orthodontic force on soft md hard tissues surrounding C-Palatal $Plate^{TM}$ in beagle Dog. Immediately after this appliance was implanted on the midpalate of 4 adult beagle Dogs, 400gm continuous orthodontic force was applied. Experimental animals were euthanized at 8weeks, 18weeks, and 22weeks (including post-removal healing time of 4weeks), and a control animal was euthanized at 8weeks after implantation without orthodontic force application. The appliance and the surrounding tissue were studied radiographically, macroscopically, and histologically. The results were as follows: 1. The lateral radiographs taken after euthanasia showed very slight displacement of the vortical plate in the experimental animals, compared with the control animal. Mobility test of all animals confirmed primary stability without any increase of mobility during experimental period. 2. No pathologic changes were found in the healing condition of covering soft tissue and bone-screw interface in experimental animals as well as a control animal. 3. Osseointegration was achieved in the bone-screw interface in 8weeks after implantation and the amount of osseointegration increased in 18weeks. There was little difference of osseointegration between the compression side and the tension side. 4. In the marginal bone area, slight bone apposition and resorption were found regardless of compression and tension side, while there was no change in the control animal. 5. Both 8week-animal and 18week-animal showed the new bone apposition along the surface of screws which were perforated into the nasal cavity, while the control animal showed no change. 6. After 4weeks of plate removal, the covering epithelium was repaired intactly, while the connective tissue showed loose and irregular rearrangement and the connective tissue capsule remained. The C-Palatal $Plate^{TM}$ manifested sufficient anchorage capacity in the context of histological study as well as clinical outcomes, when immediate orthodontic force was applied after implantation.

Elbow Arthrodesis with bone Autograft for the Management of Gunshot Fracture in a Dog (총상 골절 개에서 자가골 이식과 주관절 고정술)

  • Lee Jong Il;Alam Md. Rafiqul;Kim Nam soo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.60-64
    • /
    • 2005
  • A 6year-old intact male hound cross dog, weighing 23 kg, was presented to the Teaching Animal Hospital, Chonbuk National University with the history of gunshot wound at the left elbow joint. Survey radiographs of the affected elbow revealed the presence of a metallic bullet caudal to the olecranon processes and comminuted fracture of the proximal radius and ulna. The first treatment strategy included removal of the bullet and fixation of the radius and ulna using separate bone plates, bone screw, K-wire and surgical wire, was failed. The second treatment strategy included olecranon osteotomy and rigid immobilization of the elbow joint with a bone plate applied to the caudal aspect of the humerus and ulna along with autogenous bone grafts collected from the 13th rib. The optimal angle of the joint following arthrodesis of this case appeared to be 130°. This resulted in improving the case but after 60 weeks the plate was bent and there was exudation from the wound. The third treatment strategy was the same with the second except for that the bone autografts were collected from the proximal metaphyses of the ipsilateral humerus. This resulted in a successful arthrodesis 6 weeks after the surgery. Elbow arthrodesis with bone autograft resulted in acceptable function, but abnormal gait remained in the dog due to mechanical interference with the movement of the joint.

Compression Plate Fixation with Autogenous Bone Graft for Humerus Shaft Nonunion (상완골 간부 불유합에 대한 금속판 고정 및 자가골 이식술)

  • Cho, Chul-Hyun;Song, Kwang-Soon;Bae, Ki-Cheor;Kim, In-Kyoo;Kwon, Doo-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: To evaluate the results of the compression plate fixation and autogenous bone graft in the management of humerus shaft nonunion. Materials and Methods: Eighteen cases were treated for humerus shaft nonunion using compression plate fixation and an autogenous iliac bone graft. The mean follow-up period was 28 months. Bony union was confirmed from the serial radiographs and the clinical outcomes were assessed according to ASES scoring system. Results: In 12 cases of initial plate fixation, the causes of nonunion were 6 cases of inadequate plate length, 2 with a broken plate, 2 with screw loosening, 1 infection and 1 noncompliance of a psychiatric patient. In 3 cases of initial intramedullary fixation, the cause of nonunion was a distraction of the fracture site. In 3 cases of external fixation, the cause of nonunion was inadequate fixation. All cases showed bony union after an average of 24 weeks. The clinical outcomes were 11 excellent, 6 good and 1 fair. Conclusion: In the treatment for nonunion, compression plate fixation with autogeneous bone graft after complete removal of the fibrous and necrotic tissue is believed to give satisfactory results.