• Title/Summary/Keyword: Plate analysis

Search Result 6,022, Processing Time 0.038 seconds

Enhancement of the Thermostability of a Fibrinolytic Enzyme from Bacillus amyloliquefaciens CH51 (Bacillus amyloliquefaciens CH51이 생산하는 혈전용해효소의 열안정성 개선)

  • Kim, Jieun;Choi, Kyoung-Hwa;Kim, Jeong Hwan;Song, Young-Sun;Cha, Jaeho
    • Journal of Life Science
    • /
    • v.23 no.1
    • /
    • pp.15-23
    • /
    • 2013
  • AprE51 from Bacillus amyloliquefaciens CH51 is a 27 kDa subtilisin-like protease with fibrinolytic activity. AprE51-6 showing increased catalytic activity was produced previously. To enhance the thermostability of AprE51-6, 2 residues, Gly-166 and Asn-218 based on B. subtilis subtilisin E were mutated by site-directed mutagenesis. The results of the mutational analysis showed that substitution of arginine for Gly-166 (AprE51-7) increased the fibrinolytic activity 1.8-fold. An N218S mutant (AprE51-8) also increased the fibrinolytic activity up to 4.5-fold in a fibrin plate assay. Purified AprE51-7 and AprE51-8 mutants had a 1.9- and a 2.5-fold higher $k_{cat}$, respectively, and a 2.1-1.9-fold lower $K_m$, respectively. This resulted in a 3.8- and a 4.7-fold increase in catalytic efficiency ($k_{cat}/K_m$), respectively, relative to that of wild-type AprE51. AprE51-8 had a broader pH range than AprE51-6 and nattokinase, especially at an alkaline pH value. In addition, AprE51-8 showed higher thermostability than AprE51-6 at $60^{\circ}C$. The half-lives of AprE51-7 and AprE51-8 at $50^{\circ}C$ were 21.5 and 27.3 min, respectively, which are 2.0 and 2.6 times longer, respectively, than that of the wild-type AprE51.

The Traditional Garden Conservation Techniques through Partial Restoration Case - Focusing on the Palace Garden Sites of Korea, China and Japan - (일부 복원 사례를 통해 본 전통정원 보존기법 - 한·중·일 궁궐정원 유적을 중심으로 -)

  • Kim, Dong-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.28-35
    • /
    • 2020
  • This study aims to analyze restoration techniques of traditional garden sites targeted Korean, Chinese, Japanese palace garden. Restoration was divided into the restore foundation and restore individual elements depending on the residual state of the actual garden features. And derived characteristics that should be considered by conservation techniques. The results are as follows; First, the Wanfo Pavilion Area in Beihai Park where the foundation and foundation stones were restored based on the relevant literature and comparative analysis. The Archaeological Site in Gwanbuk-ri, Buyeo restored only the remaining structures of the ponds, waterways and large buildings among the areas where the excavation was completed. The Second Daigokuden Garden in Heijokyo Palace restored building sites and foundation, and installed poles and piles so that the area of the Second Daigokuden Garden could be known. Second, Donggung Palace and Wolji Pond, Gyeongju where the restoration of individual elements was made, preemptively restored the remains of traditional gardens based on pond garden estuaries and feedbacks that were confirmed through initial excavation. Huanghuazhen Area in Yuanmingyuan Garden was restored based on Western copper plate prints and related records, but further data found after the restoration confirmed that it was restored differently than it is now. East Palace Garden in Heijokyo Palace covered existing features with soil and restored buildings on them. Typical garden elements such as landscape stone and waterways were preserved and exposed. Third, foundation restore is a case in which the base is identified through the current state of the traditional garden site, it is important to restore the foundation first and secure the territoriality when there is no restoration plan for the elevation structure or size of the garden relics. Restoration of individual garden elements requires careful examination of the literature by limiting the restoration of objects that can be restored through the examination of the literature for each element, such as some buildings or facilities in the traditional garden site.

Clinical Analysis of Fractures by Inline Skating Injury (인라인 스케이트시 발생된 골절의 임상적 고찰)

  • Choi Hyung Suk;Doh Hyun Woo;Lee Byung Ill;Min Kyung Dae;Rah Soo Kyun;Kim Yeon Ill;Seo Yoo Sung
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.87-91
    • /
    • 2004
  • Purpose: The purpose of this study is to investigate the incidence and patterns of fractures occurred in Inline skating accident. Materials and Method: We evaluated 20 patients, 20 cases(from september 2002 to August 2003) with fractures occurred during Inline skating. The incidence, sex, age, fracture site, associated injuries, causes of Inline skating injuries were analysed. The cases were male in 18(90$\%$), and female in 2(10$\%$). The most common distribution of age was in twenties and thirties. Result: The patients(12cases 60$\%$) with upper extremity fracture were more common than patients(8cases 40$\%$) with lower extremity fracture. Patients who had fracture in ankle were 35$\%$(7cases), forearm 20$\%$(4cases), wrist 20$\%$(4cases), elbow 15$\%$(3cases), thigh 5$\%$(1cases). According to the The Lauge-Hansen classification in ankle fractures there were four patients of supination-external rotation type, two patients of supination-abduction type, and 1 patient of pronation-external rotation type. In forearm and hand fractures, there were three distal radius fractures, one radio-ulnar shaft fracture, 2 scaphoid fractures, and two meta-carpal fractures. In elbow fractures, there were two supracondyle fractures, and one lateral condyle fracture. There were three epiphyseal plate injuries (Salt-Harris type II) in children, and all of them were treated by conservative method. Six fractures were intra-articular fractures. The most common associated injury was contusion(8cases 42.1$\%$). The number of patients who only rode Inline skating less than 3months(8cases 40$\%$) was the greatest. The number of non-contact injury(14cases, 70$\%$) in Inline skating was more than contact(6cases,30$\%$) injury. 11cases(55$\%$) had operative treatment, and 9cases(45$\%$) had conservative treatment, and there was not any complication. The more detailed study is required since the materials were only limited to fracture patients, and the follow up period was short. Conclusion: The most common age for fracture in Inline skating was in twenties, and thirties, and ankle was the most common fracture site.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

Assessment of Microbiological Quality for Raw Materials and Cooked Foods in Elementary School Food Establishment (초등학교에 공급되는 급식용 식재료 및 조리식품의 미생물학적 품질평가)

  • Shin, Weon-Sun;Hong, Wan-Soo;Lee, Kyung-Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.3
    • /
    • pp.379-389
    • /
    • 2008
  • This study was conducted to assess the microbiological quality of raw and cooked foods served in the elementary school food service. Raw and cooked food samples were collected from 11 selected elementary schools in both June to July and September to October of 2005. Petrifilm plates were used to determine (in duplicate) total aerobic colony counts (PAC), Enterobacteriaceae (PE), coliform counts (PCC), and E. coli counts (PEC). Heavy contamination of Enterobacteriaceae (from 0.08 to 7.40 log CFU/g) and total coliform (0.50 to 6.52 log CFU/g) were observed in raw materials and cooked foods. Escherichia coli (E. coli) were detected in the sample of currant tomato (3.70 log CFU/g), sesame leaf (3.59 log CFU/g), dropwort (0.20 log CFU/g), crown daisy (3.15 log CFU/g), parsley (3.00 log CFU/g), peeled green onion (1.74 log CFU/g), frozen pork (0.65 log CFU/g), frozen beef (0.20 or 1.50 log CFU/g), chicken (1.78 log CFU/g), and young radish leaf seasoned with soybean paste (1.24 log CFU/g). Multiplex PCR system was used to determine the food-borne pathogens: Salmonella spp., Bacillus cereus (B. cereus), E. coli O157:H7, Staphylococcus aureus, Listeria monocytogenes (L. monocytogenes), Vibrio parahaemolyticus, Campylobacter jejuni (C. jejuni), Shigella spp., B. cereus was detected in 19 samples of raw materials and 8 samples of cooked foods. With regard to quantitative analysis, B. cereus counts exceeded 5.46, 3.48 and 1.79 log CFU/g in sesame leaf, peeled green onion and seasoned mungbean jelly, respectively. E. coli O157:H7 was detected on 2 samples of frozen beefs, and its biochemical characteristics of one beef sample was confirmed with API 20E kit (93.7%). L. monocytogenes was detected in fried rice paper dumpling, but the presumptive colonies were not detected onto the conventional plate. C. jejuni was detected in peeled & washed onion.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2011 (설비공학 분야의 최근 연구 동향: 2011년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Paik, Yong-Kyoo;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.521-537
    • /
    • 2012
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2011. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of fluid machinery and fluid flow, thermodynamic cycle, and new and renewable energy. Various topics were presented in the field of fluid machinery and fluid flow. Research issues mainly focused on the rankine cycle in the field of thermodynamic cycle. In the new and renewable energy area, researches were presented on geothermal energy, fuel cell, biogas, reformer, solar water heating system, and metane hydration. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, nanofluids and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer above liquid helium surface in a cryostat, methane hydrate formation, heat and mass transfer in a liquid desiccant dehumidifier, thermoelectric air-cooling system, heat transfer in multiple slot impinging jet, and heat transfer enhancement by protrusion-in-dimples. In the area of pool boiling and condensing heat transfer, researches on pool boiling of water in low-fin and turbo-B surfaces, pool boiling of R245a, convective boiling two-phase flow in trapezoidal microchannels, condensing of FC-72 on pin-finned surfaces, and natural circulation vertical evaporator were actively performed. In the area of nanofluids, thermal characteristics of heat pipes using water-based MWCNT nanofluids and the thermal conductivity and viscosity were measured. In the area of industrial heat exchangers, researches on fin-tube heat exchangers for waste gas heat recovery and Chevron type plate heat exchanger were implemented. (3) Refrigeration systems with alternative refrigerants such as $CO_2$, hydrocarbons, and mixed refrigerants were studied. Heating performance improvement of heat pump systems were tried applying supplementary components such as a refrigerant heater or a solar collector. The effects of frost growth were studied on the operation characteristic of refrigeration systems and the energy performance of various defrost methods were evaluated. The current situation of the domestic cold storage facilities was analyzed and the future demand was predicted. (4) In building mechanical system fields, a variety of studies were conducted to achieve effective consumption of heat and maximize efficiency of heat in buildings. Various researches were performed to maximize performance of mechanical devices and optimize the operation of HVAC systems. (5) In the fields of architectural environment and energy, diverse purposes of studies were conducted such as indoor environment, building energy, and renewable energy. In particular, renewable energy and building energy-related researches have mainly been studied as reflecting the global interests. In addition, various researches have been performed for reducing cooling load in a building using spot exhaust air, natural ventilation and energy efficiency systems.

Adhesion Characteristics and the High Pressure Resistance of Biofilm Bacteria in Seawater Reverse Osmosis Desalination Process (역삼투 해수담수화 공정 내 바이오필름 형성 미생물의 부착 및 고압내성 특성)

  • Jung, Ji-Yeon;Lee, Jin-Wook;Kim, Sung-Youn;Kim, In-S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.51-57
    • /
    • 2009
  • Biofouling in seawater reverse osmosis (SWRO) desalination process causes many problems such as flux decline, biodegradation of membrane, increased cleaning time, and increased energy consumption and operational cost. Therefore biofouling is considered as the most critical problem in system operation. To control biofouling in early stage, detection of the most problematic bacteria causing biofouling is required. In this study, six model bacteria were chosen; Bacillus sp., Flavobacterium sp., Mycobacterium sp., Pseudomonas aeruginosa, Pseudomonas fluorescens, and Rhodobacter sp. based on report in the literature and phylogenetic analysis of seawater intake and fouled RO membrane. The adhesion to RO membrane, the high pressure resistance, and the hydrophobicity of the six model bacteria were examined to find out their fouling potential. Rhodobacter sp. and Mycobacterium sp. were found to attach very well to RO membrane surface compared to others used in this study. The test of hydrophobicity revealed that the bacteria which have high hydrophobicity or similar contact angle with RO membrane ($63^{\circ}$ of contact angle) easily attached to RO membrane surface. P. aeruginosa which is highly hydrophilic ($23.07^{\circ}$ of contact angle) showed the least adhesion characteristic among six model bacteria. After applying a pressure of 800 psi to the sample, Rhodobacter sp. was found to show the highest reduction rate; with 59-73% of the cells removed from the membrane under pressure. P. fluorescens on the other hand analyzed as the most pressure resistant bacteria among six model bacteria. The difference between reduction rates using direct counting and plate counting indicates that the viability of each model bacteria was affected significantly from the high pressure. Most cells subjected to high pressure were unable to form colonies even thought they maintained their structural integrity.

Types and Characteristics of Fibrous Serpentine Minerals Occurred in Serpentinite in Hongseong and Gapyeong (홍성과 가평 사문암 내에서 섬유상으로 산출되는 사문석군 광물의 종류 및 특성)

  • Jeong, Hyewon;Kang, Serku;Roh, Yul
    • Economic and Environmental Geology
    • /
    • v.49 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • Chrysotile is well known as a fibrous mineral in serpentinite by the previous studies in S. Korea. Previous studies in other countries showed that antigorite also occurred as asbestiform and harmful to humans. Therefore, the objective of this study was to investigate types and characteristics of fibrous serpentine minerals occurred in serpentinite in Hongseong, Chungnam and Gapyeong, Gyeonggi in S. Korea. XRD, SEM-EDS, PLM and EPMA mapping analyses were used to examine the occurrence and formation mechanism of serpentine minerals. Serpentinization partially occurred in amphibole-schist and calc-schist at two study sites, Hongseong, Chungnam and Gapyeong, Gyeonggi, respectively. Both chrysotile and antigorite occurred as a fibrous mineral at Hongseong site, but chrysotile occurred as a fibrous mineral at Gapyeong site. Based on PLM analysis with dispersion staining, the chrysotile was observed horizontally magenta and vertically blue colors. The antigorite appeared as horizontally gold to golden magenta and vertically blue magenta colors under central stop dispersion staining objective(DSO). PLM and SEM analyses showed the fibrous minerals were formed from plate form of serpentine minerals or by hydrothermal alternation of primary minerals. The EPMA mapping showed that Mg contents in chrysotile is relatively higher than that in antigorite while Si and O contents in antigorite is higher than them in chrysotile. However, more studies are necessary to know the exact variation in chemical composition of chrysotile and antigorite. These results indicate that even though asbestiform antigorite found associated with asbestos chrysotile in serpentinites, the fibrous antigorite can be distinguished from chrysotile by different dispersion staining colors.

Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位))

  • Choi, In-hyuk;Kim, Soo-young;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Comparison of Phylogenetic Characteristics of Viable but Non-Culturable (VBNC) Bacterial Populations in the Pine and Quercus Forest Soil by 16S rDNA-ARDRA (16S rDNA-ARDRA법을 이용한 소나무림과 상수리나무림 토양 내 VBNC 세균군집의 계통학적 특성 비교)

  • Han Song-Ih;Kim Youn-Ji;Whang Kyung-Sook
    • Korean Journal of Microbiology
    • /
    • v.42 no.2
    • /
    • pp.116-124
    • /
    • 2006
  • In this study was performed to analyze quantitatively the number of viable but non-culturable bacteria in the Pine and Quercus forest soil by improved direct viable count (DVC) and plate count (PC) methods. The number of living bacteria of Pine and Quercus forest soil by PC method were less then 1% of DVC method. This result showed that viable but non-culturable (VBNC) bacteria existed in the forest soil with high percentage. Diversity and structure of VBNC bacterial populations in forest soil were analyzed by direct extracting of DNA and 16S rDNA-ARDRA from Pine and Quercus forest soil. Each of them obtained 111 clones and 108 clones from Pine and Quercus forest soil. Thirty different RFLP types were detected from Pine forest soil and twenty-six different RFLP types were detected from Quercus forest soil by HeaIII. From ARDRA groups, dominant clones were selected for determining their phylogenetic characteristics based on 16S rDNA sequence. Based on the 16S rDNA sequences, dominant clones from ARDRA groups of Pine forest soil were classified into 7 major phylogenetic groups ${\alpha}$-proteobacteria (12 clones), ${\gamma}$-proteobacteria (3 clones), ${\delta}$-proteobacteria (1 clone), Flexibacter/Cytophaga (1 clone), Actinobacteria (4 clones), Acidobacteria (4 clones), Planctomycetes (5 clones). Also, dominant clones from ARDRA groups of Quercus forest soil were classified into 6 major phylogenetic groups : ${\alpha}$-proteobacte,ia (4clones), ${\gamma}$-proteobacteria (2 clones), Actinobacteria (10 clones), Acidobacteria (8 clones), Planctomycetes (1 clone), and Verrucomicobia (1 clone). Result of phylogeneric analysis of microbial community from Pine and Quercus forest soils were mostly confirmed at uncultured or unidentified bacteria, VBNC bacteria of over 99% existent in forest soil were confirmed variable composition of unknown micro-organism.