• Title/Summary/Keyword: Plate Spring

검색결과 242건 처리시간 0.025초

구속상태를 고려한 반타원 표면균열의 파손평가선도 (Failure Assessment Diagrams of Semi-Elliptical Surface Crack with Constraint Effect)

  • 서헌;한태수;이형일
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.2022-2032
    • /
    • 1999
  • In recent years, the subject of remaining life assessment has drawn considerable attention in the power generation industry. In power generation systems a variety of structural components, such as steam pipes, turbine rotors, and superheater headers, typically operate at high temperatures and high pressures. Thus a life prediction methodology accounting for fracture and rupture is increasingly needed for these components. For accurate failure assessment, in addition to the single parameter such as K or J-integral used in traditional fracture mechanics, the second parameter like T-stress describing the constraint is needed. The most critical defects in such structures are generally found in the form of semi-elliptical surface cracks in the welded piping-joints. In this work, selecting the structures of surface-cracked plate and straight pipe, we first perform line-spring finite element modeling, and accompanying elastic-plastic finite element analyses. We then present a framework for including constraint effects (T-stress effects) in the R6 failure assessment diagram approach for fracture assessment.

LNG 연료추진 선박용 크랭크실 릴리프 밸브 스프링의 설계 및 평가 (Design and Evaluation of a Crankcase Relief Valve Spring for LNG-Fueled Ships)

  • 이효렬;안중환;안병훈;김화영
    • 한국생산제조학회지
    • /
    • 제24권3호
    • /
    • pp.263-269
    • /
    • 2015
  • Growing concerns regarding air pollution have recently increased the demand for liquefied natural gas (LNG) fueled ships. LNG-fueled ships are equipped with an explosion relief valve in the crankcase to relieve excessive pressure and stop flames from emitting from the crankcase. In this study, a finite element analysis was conducted to evaluate the crankcase relief valve disk spring design using an ANSYS Workbench, v.15. The setting pressure, leak and explosion test performed by european standard EN14797 to evaluate function and mechanical integrity of crankcase relief valve. The tests results indicate that the pressure of the crankcase relief valve is 3.05 bar, with no air leakage at 2.97 bar. Finally, the mechanical integrity of the crankcase relief valve was confirmed through an explosion test in which the valve plate assembly, flame arrester, and other parts were safe from fracturing.

유한두께를 가지는 보강된 균열평판에 대한 면외굽힘을 고려한 응력강도계수 계산 (Calculation of stress intensity factor considering out-of-plane bending for a patched crack with finite thickness)

  • 김종호;이순복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.165-169
    • /
    • 2000
  • A simple method was suggested to calculate the stress intensity factor for a one-sided patched crack with finite thickness. To consider out-of-plane bending effect resulting from the load-path eccentricity, the spring constant as a function of the through-thickness coordinate z was calculated from the stress distribution in the un-cracked plate, ${\sigma}_{yy}(y=0,\;z)$, and the displacement for the representative single strip Joint, $u_y(y=0,\;z)$. The stress Intensity factors were obtained using Rose's asymptotic solution approach and compared with the finite element results. In short crack region, two results had a little difference. However, two results were almost same in long crack region. On the other hand, the stress intensity factor using plane stress assumption was more similar to finite element result than plane strain condition.

  • PDF

자동차 수동 변속기 클러치 시스템의 답력 이력 특성 예측 모델 (Automotive Manual Transmission Clutch System Modeling for Foot Effort Hysteresis Characteristics Prediction)

  • 이병수
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.164-170
    • /
    • 2008
  • A typical clutch system for automotive manual transmissions transfers hydraulic pressure generated by driver's pedal manipulation to the clutch diaphragm spring. The foot effort history during the period of push is different than the period of the clutch pedal's return. The effort or load difference is called clutch foot effort hysteresis. It is known that the hysteresis is caused by friction. The frictional force and moment are produced between various component contact points such as between the rubber seal and the inner wall inside the hydraulic cylinder and between the diaphragm spring and the pressure plate, etc. Understanding the clutch pedal foot effort hysteresis is essential for a clutch release system design and analysis. The dynamic model for a clutch release system is developed for the foot effort hysteresis prediction and a simulation analysis is performed to propose a tool for analysing a clutch system.

가변용량형 피스톤펌프의 파라미터 추정 (Estimation of Parameters in a Variable Displacement Piston Pump)

  • 허준영;리차드 버튼
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.9-14
    • /
    • 2004
  • An estimation technique called the Extended Kalman filter is used to estimate viscous friction, spring initial contraction, and the spring constant on the swash plate of a variable displacement pump. The feasibility of the approach was established using a simulation study. It showed that these parameters could be estimated very accurately in a reliable and independent fashion. A special experimental system was set up to facilitate the measurement of certain states to enhance the Kalman Filtering approach. The aforementioned parameters were estimated and found to be reasonably repeatable for a common operating point. It was very evident that as the operating conditions changed (i.e. temperature) so did the estimated values of certain parameters such as viscous friction. This was believed to be a good verification test for the approach.

  • PDF

자동차 머플러용 EVV에 관한 연구 (A Study on the Exhaust Variable Valve for Automobile Muffler)

  • 박대언;박경석;박세종;손성만
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.661-665
    • /
    • 2005
  • The muffler reducing the exhaust noise and vibration from the engine influence on the engine performance. Recently the semi-active muffler was developed and adopted to the actual use in consideration of the cost and technical side for noise and vibration. This study is about the recently developed semi-active muffler. This paper attempt to analyze the dynamic stress field on the gate plate by using the finite element methods. According to the analysis of the Exhaust Variable Valve, its spring has the most influence on its operation compare with effects of other components. The design parameters of the Exhaust Variable Valve such as the spring displacement, diameter, coil number, free angle and so forth were used.

  • PDF

시설 포도 유기농 재배지에서 녹비 생육 중 녹비 종류가 토양 미생물상에 미치는 영향 (Influence of Growing Green Manures on Soil Microbial Activity and Diversity under Organically Managed Grape-greenhouse)

  • 박기춘;서영진;김찬용;김종수;이영근;서지애
    • 한국환경농학회지
    • /
    • 제27권3호
    • /
    • pp.260-266
    • /
    • 2008
  • 시설 유기농 포도 재배지에서 공중 질소 고정과 잡초 억제를 목적으로 도입할 수 있는 월동 녹비가 녹비 생육 초기인 봄에 토양 미생물 활성과 다양성에 미치는 효과를 검토하기 위하여 헤어리 베치,자운영,레드 클로버를 녹비로 파종한 후 효소 활성과 토양 미생물 군락의 기질 이용성 및 인지질 지방산 차이에 의한 토양 미생물 다양성을 조사하였다. 탈수소효소 활성과 FDA 수화도에 의한 미생물 활성으로 측정한 토양 미생물 활성은 처리간에 차이가 없었다. Biolog Ecoplate의 평균 색도 변화는 레드 클로버가 대조구에 비하여 높았다. Biolog EcoPlate에 의한 토양 미생물 군락의 기질 이용성은 자운영 처리구가 헤어리 베치구 및 레드 클로버 처리구와 뚜렷이 구분되었다. 그리고 미생물 군락의 기능적 다양성 지수는 헤어리 베치구가 대조구 보다 유의성 있게 높았다. 인지질 지방산 구성에 의한 미생물 군락의 차이를 주요인 분석으로 분석한 결과 자운영이 대조구와 현저히 구분되었고 녹비 처리구 간에는 차이가 없었다.

볼-박판 스프링 형 체크밸브가 적용된 압전유압펌프의 가압 특성 (Pressurization Characteristics of Piezoelectric-Hydraulic Pump Adopting a Ball-Thin Plate Spring Type Check Valve)

  • 황용하;황재혁;배재성
    • 항공우주시스템공학회지
    • /
    • 제12권2호
    • /
    • pp.7-14
    • /
    • 2018
  • 본 연구에서는 소형 압전유압펌프가 적용된 브레이크 시스템의 부하압 개선을 위해 체크밸브에 대한 연구를 수행하였다. 가압 과정에서 부하의 정상상태 압력은 챔버압과 부하압이 체크밸브에 작용하는 단면적 비에 영향을 받는다. 체크밸브 유로 덮개는 역류 방지를 위해 유로의 단면적보다 넓게 제작되었기 때문에 단면적 비 조절을 위해 박판 스프링 형 체크밸브에 부가질량을 부착하는 방식을 제안하였다. 부가질량 부착에 의한 부하압 개선 효과를 확인하기 위해 상용코드를 이용하여 소형 압전유압펌프가 적용된 단순 브레이크 시스템의 모델링을 수행하였다. 모델링의 검증을 위해 부가질량이 부착되지 않은 박판 스프링 형 체크밸브를 적용한 펌프의 가압 실험결과와 시뮬레이션 결과를 비교하였다. 검증된 아메심 모델링에 부가질량을 추가하였고 시뮬레이션을 통해 단면적 비 조절에 의한 고 부하압 형성 효과를 확인하였다. 부가질량 추가에 따른 소형 압전유압펌프 구성품을 새롭게 설계/제작한 후 브레이크 시스템의 가압 성능 실험을 수행하여 부하압 35% 의 성능 개선을 확인하였다.

비균질 Pasternak지반 위에 놓인 면내력을 받는 후판의 진동해석 (Free Vibration Analysis of Thick Plate Subjected to In-plane Force on Inhomogeneous Pasternak Foundation)

  • 이용수;김일중;오숙경
    • 한국강구조학회 논문집
    • /
    • 제15권3호
    • /
    • pp.291-298
    • /
    • 2003
  • 최근 건축물의 대형화로 구조물의 기초는 비균질지반에 지지된다. 본 연구는 면내력을 받는 후판의 진동해석을 한 것이다. 장방 형판은 등방, 균질의 선형 탄성재료로 구성되었다. 장방형 후판의 진동해석은 8절점과 9절점을 이용한 장방형 유한요소를 사용하여 행하였다. 본 연구에서 기초를 수직스프링으로 이상화한 Winkler지반에 전단지반층을 추가한 Pasternk지반으로 이상화하였다. 지반의 강성을 달리한 비균질 Pasternak지반에 지지된 판을 해석하기 위해 중앙부분과 가장자리 부분의 Winkler지반계수를 WFP1과 WFP2로 선택하였다. (그림 4.) Winkler지반계수 WFP1과 WFP2는 0, 10, $10^2$, $10^3$으로 변환시키고 전단지반강성은 0, 5, 10으로 하였다. 후판의 좌굴응력(${\sigma}_{cr}$)에 대한 면내력의 비는 각각 0.4, 0.8에 대해 적용하였다.

Experimental Investigations on the Plastic Damage of Plates due to Lateral Collisions

  • Cho, Sang-Rai;Kim, Il-Woong;Lee, Sang-Bock
    • Journal of Ship and Ocean Technology
    • /
    • 제6권3호
    • /
    • pp.1-12
    • /
    • 2002
  • In this paper the results are reported of sixty-nine lateral collision tests, which were performed to investigate the collision resistance of plates. For the tests a collision testing machine of spring-roller conveyer type was designed and fabricated. Using this machine, various plates were tested with different masses and velocities and various headers of the striker. A simple analytical method has also been developed to predict the extent of damage of struck plates due to lateral collision. In the method, it is assumed that the kinetic energy of the striker can be dissipated by the formation of yield lines and membrane tensions in the impacted plate. The calculated predictions of extent of damage using the developed method have been substantiated with the test results, which shows reasonably acceptable correlations.