• 제목/요약/키워드: Plastic parts

검색결과 631건 처리시간 0.03초

Late Complication of a Silicone Implant Thirty Years after Orbital Fracture Reconstruction

  • Lee, Chi An;Kang, Seok Joo;Yun, Ji Young;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제18권2호
    • /
    • pp.137-140
    • /
    • 2017
  • Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.

완전 절단된 외이의 재접합 (Replantation of Amputated Ear)

  • 정성모;배충상;이내호;양경무
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권2호
    • /
    • pp.112-116
    • /
    • 2005
  • The auricle is easy to be amputated in the face due to its protruding position. When facial parts are amputated, the mechanism of injury usually involves some form of avulsion, which damages these fragile vessels over a distance and renders them unsuitable for anastomosis. Replantation of the ear remains a challenging problem because of the tiny vessels and the paucity of adequate veins for anastomosis. Reattachment as a composite graft of the total or subtotal amputated ear is unreliable. Microsurgical replantation can be performed in a minority of cases because of technical difficulties and long operation time. In this article, the authors report two case of a successful ear replantation of completely amputated auricle. Only one artery and one vein were anastomosed in first case. In the other case one artery was anastomosed without vein. Instead of venous repair, multiple incision was done with leech application therapy. and the outcome was successful. In spite of the technical difficulties and long operation time, microsurgical replantation of amputated ear is better than other reconstructive method or reattachment without microsurgery.

  • PDF

Fascial Free Flap for Reconstruction of the Dorsolateral Hand and Digits: The Advantage of a Thin Contour

  • Lee, Min Gue;Kim, Jin Soo;Lee, Dong Chul;Roh, Si Young;Lee, Kyung Jin;Choi, Byeong Kyoo
    • Archives of Plastic Surgery
    • /
    • 제43권6호
    • /
    • pp.551-558
    • /
    • 2016
  • Background Fascial free flaps have been widely used for reconstruction of the hand because they are thin. However, studies reporting objective data regarding the advantages of this approach are lacking. Thus, we report our experience with such flaps. Methods Forty-five cases of fascial free flaps between November 2006 and March 2014 were reviewed. Nine cases involving reconstructed dorsal or lateral defects were included. Four anterolateral thigh fascial free flaps and 5 lateral arm fascial free flaps were examined. Maximal flap contour was assessed by measuring reconstructed tissue thickness at the central area from the surface of the skin to below the bone in a vertical manner using ultrasonography and X-ray data. Contralateral regions were examined in the same manner and a comparative analysis was performed. A questionnaire survey regarding aesthetic satisfaction was also administered. Results All reconstructed parts had a thicker contour than the contralateral side. The average relative percentage of reconstructed tissue thickness was found to be 152% using ultrasonography and 143% using X-ray imaging. According to the aesthetic satisfaction survey, the average rate of satisfaction for patients was 62%, and satisfaction with the flap contour was 72%. Conclusions Using a fascial free flap, the reconstructed tissue was approximately $1.5{\times}$ as thick as the contour of the normal side, which led to positive responses regarding aesthetic satisfaction.

시설(施設) 하우스내 아황산(亞黃酸)(SO2)가스 발생현황(發生現況) 조사(調査) (Survey on the Concentration of Sulphur Dioxide Gas in the Plastic Film House Cultivation)

  • 김복영;이종식;정구복
    • 한국토양비료학회지
    • /
    • 제30권4호
    • /
    • pp.357-360
    • /
    • 1997
  • 우리나라의 전국 주요 시설재배지에 있는 비닐하우스 343동을 대상으로 시설내 공기의 아황산($SO_2$)가스 농도를 조사한 결과는 다음과 같다. 1. 하우스내 공기중 아황산($SO_2$)가스 농도는 가온하우스내 농도와 무가온 하우스농도가 유사하나 가온 하우스에서는 0.8ppm이상의 농도가 검출되었다. 2. 아황산가스는 고추재배지에서 화훼류나 오이, 토마토 재배지 보다 농도가 높고 온도가 높은 주간이 야간보다 높은 농도가 검출되었다. 3. 가온하우스의 아황산가스의 유출은 온풍기의 파손 부위와 연돌의 이음쇄 부위이며, 연돌을 통해 외부에 배출된 아황산가스가 공기 흡입으로 재유입되는 경우도 있다. 4. 환기를 하지 않은 하우스는 아황산가스 농도가 0.6ppm이나 동일한 조건에서 환기를 한 것은 0.2ppm으로 낮았다.

  • PDF

Dynamic numerical simulation of plastic deformation and residual stress in shot peening of aluminium alloy

  • Ullah, Himayat;Ullah, Baseer;Muhammad, Riaz
    • Structural Engineering and Mechanics
    • /
    • 제63권1호
    • /
    • pp.1-9
    • /
    • 2017
  • Shot peening is a cold surface treatment employed to induce residual stress field in a metallic component beneficial for increasing its fatigue strength. The experimental investigation of parameters involved in shot peening process is very complex as well as costly. The most attractive alternative is the explicit dynamics finite element (FE) analysis capable of determining the shot peening process parameters subject to the selection of a proper material's constitutive model and numerical technique. In this study, Ansys / LS-Dyna software was used to simulate the impact of steel shots of various sizes on an aluminium alloy plate described with strain rate dependent elasto-plastic material model. The impacts were carried out at various incident velocities. The influence of shot velocity and size on the plastic deformation, compressive residual stress and force-time response were investigated. The results exhibited that increasing the shot velocity and size resulted in an increase in plastic deformation of the aluminium target. However, a little effect of the shot velocity and size was observed on the magnitude of target's subsurface compressive residual stress. The obtained results were close to the published ones, and the numerical models demonstrated the capability of the method to capture the pattern of residual stress and plastic deformation observed experimentally in aluminium alloys. The study can be quite helpful in determining and selecting the optimal shot peening parameters to achieve specific level of plastic deformation and compressive residual stress in the aluminium alloy parts especially compressor blades.

Osteoplastic Reconstruction of Post-enucleatic Microorbitalism

  • Yun, Ji Young;Kang, Seok Ju;Kim, Jin Woo;Kim, Young Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.333-337
    • /
    • 2012
  • Background Patients who have undergone enucleation during infancy due to retinoblastoma can develop microorbitalism due to the decreased growth stimulation from the eyeball and the surrounding soft tissues. Anatomically, the orbit consist of parts of the frontal bone superiorly, the maxilla inferiorly, the ethmoid bone medially, and the zygoma laterally. Considering the possibility of surgically expanding the orbit using tripod osteotomy, in this study we conducted tripod osteotomy on adult patients with microorbitalism of retinoblastoma. Methods Tripod osteotomy was conducted to expand the orbital volume in adult patients with microorbitalism due to enucleation in infancy for retinoblastoma. The orbital volume was measured using the Aquarius Workstation ver. 4.3.6 and the orbit width was measured with preoperative and postoperative 3-dimensional facial bone computed tomography (CT) imaging. Preoperative and postoperative photographs were used to visualize the difference produced by the surgery. Results The orbital volume of the affected side was 10.3 $cm^3$ before and 12.5 $cm^3$ after the surgery, showing an average increase in volume of 2.2 $cm^3$ (21.4%). The increase in the obital width was confirmed by the preoperative and postoperative 3-dimensional facial CT images and aesthetic improvement was observed by the preoperative and postoperative photographs. Conclusions Tripod osteotomy, which realigns the orbital bone, zygoma, and maxilla, is used to correct posttraumatic malunion as well as non-traumatic congenital abnormalities such as that seen in facial cleft. We applied this procedure in microorbitalism secondary to enucleation for retinoblastoma to allow orbital expansion and correct asymmetry.

소음예측 비례식을 이용한 자동차 엔진 공회전 속도 제어 장치 유로의 저소음 디자인 (Low-Noise Design of Passage of Idle Speed Control Actuator in Automotive Engines Using Scaling Laws for Noise Prediction)

  • 정철웅;김재헌;박용환;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.283-290
    • /
    • 2007
  • Recently, plastic products in air-intake parts of automotive engines have become very popular due to advantages that include reduced weight, constricted cost, and lower intake air temperature. However, flow-induced noise in air-intake parts becomes a more serious problem for plastic intake-manifolds than for conventional aluminum-made manifolds. This is due to the fact that plastic manifolds transmit more noise owing to their lower material density. Internal aerodynamic noise from an Idle Speed control Actuator (ISA) is qualitatively analyzed by using a scaling law, which is expressed with some flow parameters such as pressure drop, maximum flow velocity, and turbulence kinetic energy. First, basic flow characteristics through ISA passage are identified with the flow predictions obtained by applying Computational Fluid Dynamics techniques. Then, the effects on ISA passage noise of each design factors including the duct turning shape and vane geometries are assessed. Based on these results, the preliminary low noise design for the ISA passage are proposed. The current method for the prediction of internal aerodynamic noise consists of the steady CFD and the scaling laws for the noise prediction. This combination is most cost-effective, compared with other methods, and therefore is believed to be suited for the preliminary design tool in the industrial field.

  • PDF

소음예측 비례식을 이용한 자동차 엔진 공회전 속도 제어 장치 유로의 저소음 설계 (Low-noise Design of Passage of Idle Speed Control Actuator In Automotive Engines Using Scaling Laws for Noise Prediction)

  • 정철웅;김재현;김성태;박용환;이수갑
    • 한국소음진동공학회논문집
    • /
    • 제17권8호
    • /
    • pp.683-692
    • /
    • 2007
  • Recently, plastic products in air-intake parts of automotive engines have become very popular due to advantages that include reduced weight, constricted cost, and lower intake air temperature. However, flow-induced noise in air-intake parts becomes a more serious problem for plastic intake-manifolds than for conventional aluminum-made manifolds. This is due to the fact that plastic manifolds transmit more noise owing to their lower material density. Internal aerodynamic noise from an idle speed control actuator(ISA) is qualitatively analyzed by using a scaling law, which is expressed with some flow parameters such as pressure drop, maximum flow velocity, and turbulence kinetic energy. First, basic flow characteristics through ISA passage are identified with the flow predictions obtained by applying computational fluid dynamics techniques. Then, the effects on ISA passage noise of each design factors including the duct turning shape and vane geometries are assessed. Based on these results, the preliminary low noise design for the ISA passage are proposed. The current method for the prediction of internal aerodynamic noise consists of the steady CFD and the scaling laws for the noise prediction. This combination is most cost-effective, compared with other methods, and therefore is believed to be suited for the preliminary design tool in the industrial field.

최근 5년간 유리 피판술을 이용한 하지재건의 분석 (Analysis of the Lower Extremity Reconstruction with Free Tissue Transfer in Recent 5 Years)

  • 백승준;허찬영;오갑성
    • Archives of Reconstructive Microsurgery
    • /
    • 제8권2호
    • /
    • pp.130-138
    • /
    • 1999
  • The lower extremity injuries are extremely increasing with the development of industrial & transportational technology. For the lower extremity injuries that result from high-energy forces, particularly those in which soft tissue and large segments of bone have been destroyed and there is some degree of vascular compromise, the problems in reconstruction are major and more complex. In such cases local muscle coverage is probably unsuccessful, because adjacent muscles are destroyed much more than one can initially expect. Reconstruction of the lower extremity has been planned by dividing the lower leg into three parts traditionally The flaps available in each of the three parts are gastrocnemius flap for proximal one third, soleus flap for middle one third and free flap transfer for lower one third. Microvascular surgery can provide the necessary soft tissue coverage from the remote donnor area by free flap transfer into the defect. Correct selection of the appropriate recipient vessels is difficult and remains the most important factor in successful free flap transfer. Vascular anastomosis to recipient vessels distal to the zone of injury has been advocated and retrograde flow flaps are well established in island flaps. Retrograde flow anastomosis could not interrupt the major blood vessels which were essential for survival of the distal limb, the compromise of fracture or wound healing might be prevented. During 5 years, from March 1993 to Feb. 1998, we have done 68 free flap transfers in 61 patients to reconstruct the lower extremity. From analysis of the cases, we concluded that for the reconstruction of the lower extremity, free flap transfer yields a more esthetic and functional results.

  • PDF

반복하중하에서의 강부재에 대한 손상지수 제안 (A Proposal for Damage Index of Steel Members under Cyclic Loading)

  • 박연수;강대흥;오정태;최동호;오백만
    • 한국강구조학회 논문집
    • /
    • 제14권5호통권60호
    • /
    • pp.613-625
    • /
    • 2002
  • 본 연구는 강한 반복하중하에서 강부재가 파괴에 이르는 손상과정을 규명하고, 손상과 관련된 인자들을 이용하여 손상지수를 제시하며, 이와 관련된 해석 기법을 개발하는 것을 목적으로 한다. 제안된 손상평가 방법은 변형이 가장 심하게 집중된 단면에 있어서 국소 변형율의 이력에 초점을 맞추어 유도되었다. 해석모델은 좌굴변형의 발생 방향을 가정한 켄틸레버형 강상자형 부재이다. 파괴에 이르는 중심 압축하중과 일정 압축하중이 가해진 상태에서 반복 제어변위가 작용하는 강부재에 대해 비선형해석을 실시하였다. 본 해석에 적용된 주요 변수는 하중 재하패턴, 강종이다. 각 변수가 파괴모드, 변형능력, 그리고 손상과정에 미치는 영향을 기술하였고, 각각 강종에 따른 파괴 과정을 비교하였다. 그 결과 강한 반복하중하에서의 강부재의 파괴는 국부좌굴에 의해서 결정되고 특히 파괴와 직접적으로 연관성이 있는 국소 소성변형율과 관련되어 있음을 알 수 있었다.