• 제목/요약/키워드: Plastic and drying shrinkage

검색결과 41건 처리시간 0.019초

CFRD 차수벽 콘크리트의 균열 특성에 미치는 각종 영향요인에 관한 연구 (A Study on the Influence Factors on Crack Properties of CFRD Face Slab Concrete)

  • 최세진;임정열;김완영;김무한
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.109-117
    • /
    • 2000
  • CFRD(Concrete Faced Rockfill Dam) face slab concrete has a much capability to occur crack due to drying shrinkage, plastic shrinkage and bad compaction etc. Because of these cracks of concrete induce structural problem and decrease durability of dam, it is need to reduce crack of face slab concrete. This is an experimental study to analyze the influence factors on crack properties of CFRD face slab concrete. For this purpose, various mix proportion of CFRD face slab concrete and concrete using PPF(polypropylene fiber0 and fly ash was selected. And tests for drying shrinkage, bonding strength, water permeability and plastic shrinkage were performed, and then CFRD D and PPC of those mix proportion were placed in CFRD field. According to test results, it was found that the bonding strength of C1(compact sufficiently) was higher about 10~20% than that of C2(compact insufficiently). And the engineering properties of PPC(concrete using PPF) and FAC(concrete using fly ash) were better than those of the others ; the permeability of PPC and FAC after 8 weeks curing was little lower than that of CFRD D, and plastic shrinkage crack of PPC and FAC was lower 40~60% than crack of CFRD D.

버블시트 피복양생법에 의한 소성 및 건조수축 균열저감 (Plastic and Drying Shrinkage Cracking Reduction by the Bubble Sheet Curing)

  • 이정교;한천구
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.211-217
    • /
    • 2016
  • 본 연구에서는 2015년 가을철 실제 시공중인 고층 아파트를 대상으로 1중 백색 버블시트로 타설된 콘크리트의 표면을 덮어주는 버블시트 피복양생 공법과 표면을 노출한 채로 양생없이 유지하는 표면노출 방법간을 비교하여 소성 및 건조수축균열의 저감정도를 분석하였다. 실험 결과, 버블시트를 시공하였을 경우, 수화열 및 적산온도는 표면노출보다 약간 높았고, 바닥 균열의 갯수, 길이, 최대 균열폭, 균열 면적 모두 현저하게 적은 값이 측정되었다. 따라서 가을철 버블시트를 타설된 콘크리트 표면에 적용 할 경우에는 소성 및 건조수축균열을 획기적으로 방지할 수 있는 효과적인 표면피복 양생공법인 것으로 판단되었다.

PPF 섬유의 첨가에 따른 건조수축 특성에 관한 연구 (A Study on the Effects of PPF Fiber on Drying Shrinkage)

  • 한만엽
    • 콘크리트학회지
    • /
    • 제6권4호
    • /
    • pp.123-130
    • /
    • 1994
  • 폴리플로필렌 섬유를 첨가하여 콘크리트의 물성을 개선하려고 하는 많은 노력이 있어 왔으나, 아직 플라스틱계 섬유의 첨가에 따른 콘크리트의 거동에 대한 메카니즘은 명확히 밝혀지지 않은 상태이다. 플라스틱 섬유의 첨가에 따른 건조수축 균열의 조절 가능성을 분석하기 위하여 섬유의 첨가에 따른 유동성과 건조수축의 변화를 조사하였다. 섬유의 첨가에 따른 유동성의 변화와 건주수축을 측정하기 위한 실물 크기의 슬라브가 제작되었고, 섬유의 수분 흡착 특성 실험도 실기되었다. 실험 결과 섬유의 첨가는 상당한 유동성의 감소를 유발하기 때문에, 이를 보정하기 위한 추가적인 배합수가 필요했으며, 이에 따라 섬유의 첨가량에 비례하는 건조수축의 증가가 관측되었으나, 강도에는 큰 변화가 없는 것으로 관측되었다.

콘크리트 교량 방호벽의 균열원인 및 패턴 분석에 대한 연구 (Study on Cracking Causes and Patterns in Median Barrier and Guardrail Concrete in RC Bridge)

  • 최세진;최정욱;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.19-26
    • /
    • 2014
  • 콘크리트 방호벽 및 중앙분리대는 교량의 부속시설이지만, 슬립폼 시공과 넓은 비표면적으로 인해 초기재령 균열이 발생하기 쉽다. 본 연구에서는 대형 교량의 방호벽과 중앙분리대 콘크리트의 외관조사 및 비파괴실험을 수행하여 균열의 원인과 발생 균열의 패턴을 분석하였다. 이를 위해 시공기간을 고려하여, 건조수축, 수화열 해석이 수행되었으며, 현장의 환경조건을 고려하여 소성수축 특성을 평가하였다. 평가결과 대상구조물의 균열 원인은 철근위치에 따른 소성침하균열, 소성수축 및 건조수축에 의한 복부균열, 재료분리에 따른 상부균열로 추정할 수 있었다. 또한 균열원인과 발생 패턴을 도식화하였으며, 시공 및 재료분야에서 균열제어대책을 제안하였다. 해상위 교량에 설치하는 중앙분리대 및 방호벽 콘크리트는 환경조건 (풍속, 온도, 습도)에 매우 민감하여 초기재령균열이 쉽게 발생하므로 재료선택 및 시공방법에 신중을 기해야 한다.

성형직후 증발작용을 받은 콘크리트의 강도에 대한 연구 (A Study on Compressive Strength of Concrete Exposed to Evaporation Immediately After Casting)

  • 오무영
    • 한국농공학회지
    • /
    • 제16권4호
    • /
    • pp.3545-3554
    • /
    • 1974
  • The objective of this study was to investigate the characteristics of the evaporation rate, the plastic shrinkage and the compressive strength of concrete exposed to a rapid evaporation environment immediately after casting. Drying of concrete were conducted under a controlled chamber in which the temperature was mainfoimed at 30 ${\pm}$1$^{\circ}C$, the relative humidity 22 ${\pm}$1 percent, and the wind velocity 7 ${\pm}$1 m/sec. The compressive strength of concrete was tested after 28 days of standard curing. The results obtained are as follows: 1. The evaporation rate was the highest at the very beginning, was decreased as the drying progresses, and was kept almost constant after 6 hours. 2. The shrinkage of concrete was changed in three different rates for the concrete mixture having its slump vallue between 3.0cm and 7.5cm. 3. The plastic shrinkage was ended within 5 or 6 hours after casting, regardless of the water cement ratio. 4. The shrinkage was increased within the limit of slump values between 3.0cm and 7.5cm as the water-cement ratio was increased. 5. The evaporation was kept on even after the plastic shrinkage was ended. 6. Within the limit of good workability (slump value between 4.5cm and 7.5cm), the compressive strength of concrete was increased when the shrinkage rate was slow but it was decreased when the rate was rapid 7. From the result of this study it is recommended that (1) the water-cement ratio should be less as long as the workability of concrete is allowable; (2) the evaporation should be prevented at least for 4 hours after casting concrete.

  • PDF

고흡수성수지와 팽창재 동시 혼입 시 고강도 모르타르의 수축거동에 미치는 영향 (Effect of Combined Superabsorbent Polymers and Expansion Agent on Shrinkage Behavior of High Strength Mortar)

  • 김민수;홍성걸
    • 대한건축학회논문집:구조계
    • /
    • 제35권12호
    • /
    • pp.157-164
    • /
    • 2019
  • Superabsorbent polymers(SAPs) are powdery material that absorb water several tens or hundreds of times its own mass. It has been reported that when SAPs are incorporated into a high strength cementitious material, the autogenous shrinkage of the material is reduced. Cross-linked sodium polyacrylate type SAPs are relatively safe for human body and low in production cost. In order to apply this type of SAPs to the admixture for total(plastic+autogenous+drying) shrinkage reduction of high strength mortar, the shrinkage behavior of mortar when an expansion agent(EA) and SAPs were mixed together was analyzed. As a result, it was found that the shrinkage was reduced when an EA 5% (mass % of cement) and SAPs 0.4% were mixed together than the mortar containing only an EA 10%. The shrinkage was further reduced when EA 10% and SAPs 0.4% were incorporated into mortar.

콘크리트 배합조건에 따른 수축저감제의 건조수축 특성 (Drying Shrinkage Characteristics of the Concrete Incorporated Shrinkage Reducing Agent According to Mixed Proportion of Concrete)

  • 김영선;김광기;박순전;김정선
    • 한국건축시공학회지
    • /
    • 제17권3호
    • /
    • pp.245-252
    • /
    • 2017
  • 최근 소비패턴의 변화에 따라 대형마트, 아울렛 및 물류창고 등과 같은 구조물들이 증가하고 있다. 이와 같은 구조물들은 초평탄 바닥부재를 포함하고 있기 때문에 소성 및 건조수축에 의한 슬래브 부재의 균열 억제 관리를 철저하게 실시한다. 슬래브 부재의 균열을 억제하기 위한 방안으로 화학적 균열저감 방법을 사용하고 있으며, 특히 수축저감제에 대한 사용검토가 증가하고 있다. 그러나 이에 대한 국내 연구결과는 부족한 상황이다. 본 연구에서는 수축저감제를 사용한 콘크리트의 수축특성과 배합요인 변동에 따른 건조수축 특성을 검토하였다. 국내 수축저감제는 해외 고급형 수축저감제와 성능이 유사한 것으로 나타났으며, 수축저감제 사용량이 증가할수록 건조수축 억제 효과는 높아지는 것으로 나타났다. 수축저감제 1.5%를 사용한 시험체는 재령 100일에서 수축저감제를 사용하지 않은 시험체에 비해 건조수축량이 약 절반으로 나타났다. 또한, 혼화재료 사용에 대해 특별한 성능변화는 없는 것으로 확인되었다.

콘크리트 초기 수축균열특성 평가를 위한 판상-링형 구속시험방법의 성능평가에 관한 연구 (A Study on the Development of Flat-Ring Type Restrained Test Method and Performance Evaluation for Evaluating Shrinkage Cracking Properties of Concrete in Early Age)

  • 김규용;최형길;이의배;남정수;한민기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권3호통권55호
    • /
    • pp.188-196
    • /
    • 2009
  • 콘크리트는 초기재령에 있어서 수분의 증발 및 이동으로 소성 및 건조수축 등의 수축현상이 발생한 다. 국내에서는 아령형 구속건조수축몰드를 활용한 콘크리트의 건조수축 균열 평가방법을 KS에서 규격화하여 활용하고 있으나 이는 균열발생시점 및 구속수축응력을 평가하는 방법으로 균열발생량에 관한 정량적 평가는 어려운 실정이다. 이에 본 연구에서는 콘크리트의 수축변형거동 및 균열발생량에 대한 정량적 데이터를 확보하기 위하여 판상-링형 구속시험방법을 개발하고 시험체 치수가 콘크리트의 수축균열에 미치는 영향을 검토하여 판상-링형 구속시험방법의 최적 시험체 치수 도출 및 수축균열특성에 관한 정량적 평가방법을 제안하고 그 적용성을 검증하고자 한다.

분할타설되는 콘크리트 슬래브의 소성수축균열 특성에 대한 해석적 연구 (A Numerical Study on the Characteristics of Plastic Shrinkage Cracking on Concrete Slab with Sequential Placement)

  • 곽효경;하수준
    • 대한토목학회논문집
    • /
    • 제26권4A호
    • /
    • pp.795-808
    • /
    • 2006
  • 이 논문에서는 참고문헌(곽효경 등, 2004; 곽효경 등, 2005)에서 제안된 소성수축균열 해석모델을 바탕으로 분할타설되는 콘크리트 슬래브의 소성수축균열 해석방법을 제안하였다. 이 해석방법을 이용해 슬래브의 분할타설이 소성수축균열에 미치는 영향에 대해 알아보았고 분할타설방법에 따른 소성수축균열 발생 특성을 정량적으로 분석하였다. 나아가 콘크리트 배합과 외기조건 및 분할타설방법을 변수로 하여 수행한 소성수축균열 해석으로부터 얻어진 해석결과를 바탕으로 슬래브의 표면 건조시기와 먼저 타설된 콘크리트의 표면 건조를 방지하기 위한 임계 타설시간간격에 대한 모델식을 제안함으로써 슬래브에 소성수축균열이 발생하지 않도록 분할타설방법을 계획하거나 소성수축균열의 제어를 위해 적절한 시기에 양생을 시작할 수 있도록 하였다.

A review on the application of plastic waste in the reinforced concrete structures

  • K. Senthil;Suresh Jakhar;Manish Khanna;Kavita Rani
    • Advances in materials Research
    • /
    • 제13권2호
    • /
    • pp.115-128
    • /
    • 2024
  • Concrete is the most significant material in the construction industry which is required to construct several facilities like roads, buildings, and bridges etc. which leads to the economic development of a country. But now days, in view of sustainable development and environmental problems, plastic waste management is one of the major environmental issues due to its non-biodegradable nature which allows it to stay in the landfills until they are cleaned up. To overcome all these concerns, plastic waste may be used as a substitute of natural fine and coarse aggregate in concrete and a valuable solution to utilize the plastic items which causes several problems. In order to, present study is focused on the affecting properties of concrete as workability, compressive strength, and tensile strength of concrete with using plastic waste and without using plastic waste. Based on the detailed literature, it was observed that the plastic waste is not affecting the quality and consistency of concrete. However, as the number of PVC particles in the mixture increased, the drying shrinkage values decreased and the inclusion of plastic flakes can mitigate drying shrinkage cracking which leads the higher durability of concrete. Based on the comprehensive literature, it was also observed that the plastic aggregate found to be suitable for low and medium strength concrete. However, the investigation on the application of plastic aggregate in the high strength concrete is found limited. It was concluded that the optimum percentage of the plastic aggregate was found about 20%.