• 제목/요약/키워드: Plastic Ring

검색결과 146건 처리시간 0.036초

Deformation Characteristics and Sealing Performance of Metallic O-rings for a Reactor Pressure Vessel

  • Shen, Mingxue;Peng, Xudong;Xie, Linjun;Meng, Xiangkai;Li, Xinggen
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.533-544
    • /
    • 2016
  • This paper provides a reference to determine the seal performance of metallic O-rings for a reactor pressure vessel (RPV). A nonlinear elastic-plastic model of an O-ring was constructed by the finite element method to analyze its intrinsic properties. It is also validated by experiments on scaled samples. The effects of the compression ratio, the geometrical parameters of the O-ring, and the structure parameters of the groove on the flange are discussed in detail. The results showed that the numerical analysis of the O-ring agrees well with the experimental data, the compression ratio has an important role in the distribution and magnitude of contact stress, and a suitable gap between the sidewall and groove can improve the sealing capability of the O-ring. After the optimization of the sealing structure, some key parameters of the O-ring (i.e., compression ratio, cross-section diameter, wall thickness, sidewall gap) have been recommended for application in megakilowatt class nuclear power plants. Furthermore, air tightness and thermal cycling tests were performed to verify the rationality of the finite element method and to reliably evaluate the sealing performance of a RPV.

Flexor Tenorrhaphy Using Absorbable Suture Materials

  • Kang, Hyung Joo;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.397-403
    • /
    • 2012
  • Background Nonabsorbable sutures are favorable for repairing flexor tendons. However, absorbable sutures have performed favorably in an animal model. Methods Two-strand sutures using the interlocking modified Kessler method with polydioxanone absorbable sutures 4-0 were used to repair completely ruptured flexor tendons in 55 fingers from 41 consecutive patients. The medical records of average 42 follow up weeks were analyzed retrospectively. The data analyzed using the chi-squared test, and Fisher's exact test was used for postoperative complications. The results were compared with those of other studies. Results Among the index, middle, ring, and little fingers were injured in 9, 17, 16, and 13 fingers, respectively. The injury levels varied from zone 1 to 5. Of the 55 digits in our study, there were 26 (47%) isolated flexor digitorum profundus (FDP) injuries and 29 (53%) combined FDP and with flexor digitorum superficialis injuries. Pulley repair was also conducted. Concomitant injuries of blood vessels and nerves were found in 17 patients (23 fingers); nerve injuries occurred in 5 patients (10 fingers). Two patients had ruptures (3.6%), and one patient had two adhesions (3.6%). Using the original Strickland criteria, all the patients were assessed to be excellent or good. Also, fibrosis and long-term foreign body tissue reactions such as stitch granuloma were less likely occurred in our study. Compared to the Cullen's report that used nonabsorbable sutures, there was no significant difference in the rupture or adhesion rates. Conclusions Therefore, this study suggests that appropriate absorbable core sutures can be used safely for flexor tendon repairs.

수근관에 발생한 결절종으로 인한 수근관 증후군의 치험1례 (Carpal Tunnel Syndrome by Ganglion: A Case Report)

  • 장서윤;안덕선
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: Carpal tunnel syndrome is the most common peripheral compressive neuropathy. Most cases are idiopathic, but rarely carpal tunnel syndrome can be associated with a ganglionic mass. We report our recently encountered experience of surgical treatment of carpal tunnel syndrome caused by a simple ganglionic mass. Methods: A 53-year-old man presented with chief complaints of numbness and hypoesthesia of his left palm, thumb, index finger, long finger, and ring finger of one and half month duration. Physical examination revealed positive Tinnel's sign without previous trauma, infection or any other events. Electromyography showed entrapment neuropathy of the median nerve. Magnetic resonance imaging (MRI) showed an approximately 2.0 cm-sized mass below the transverse carpal ligament. Upon surgical excision, a $1{\times}1.5cm^2$ mass attached to the perineurium of the median nerve and synovial sheath of the flexor digitorum superficialis and redness and hypertrophy of the median nerve were discovered. With surgical intervention, we completely removed the ganglionic mass and performed surgical release of the transverse carpal ligament. Results: The pathology report confirmed the mass to be a ganglion. The patient exhibited post-operative improvement of his symptoms and did not show any complications. Conclusion: We present a review of our experience with this rare case of carpal tunnel syndrome caused by a ganglionic mass and give a detailed follow-up on the patient treated by surgical exploration with carpal tunnel release.

강소성 유한요소해석에서 Hourglass Control (Hourglass Control in Rigid-Plastic Finite Element Analysis)

  • 강정진;오수익
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1290-1300
    • /
    • 1996
  • The finite element method, based on rigid-plastic formulation, is widely used to simulate metal forming processes. In order to improve the computational efficiency of the rigid-plastic FEM, one-point integration is used to evaluate the stiffness matrix with four-node rectangular elements and eight-node brick elements. In order to control the hourglass modes, hourglass strain rate components were introduced and included in the effective strain rate definition, Numerical tests have shown that the proposed one-point integration scheme reduces the stiffness matrix evaluation time without deteriorating the convergence behavior of Newton-Raphson method. Simulations of a ring compression, a plane-strain closed-die forging and the three-dimensional spike forging processes were carried out by using the proposed integration method. The simulation results are compared to those obtained by applying the conventional integraiton method in terms of the solution accuracy and computational efficiency.

Fingernail Configuration

  • Jung, Jin Woo;Kim, Kwang Seog;Shin, Jun Ho;Kwon, Yu Jin;Hwang, Jae Ha;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • 제42권6호
    • /
    • pp.753-760
    • /
    • 2015
  • Background A number of conditions can alter a person's fingernail configuration. The ratio between fingernail width and length (W/L) is an important aesthetic criterion, and some underlying diseases can alter the size of the fingernail. Fingernail curvature can be altered by systemic disorders or disorders of the fingernail itself. Although the shape and curvature of the fingernail can provide diagnostic clues for various diseases, few studies have precisely characterized normal fingernail configuration. Methods We measured the W/L ratio of the fingernail, transverse fingernail curvature, hand length, hand breadth, and distal interphalangeal joint width in 300 volunteers with healthy fingernails. We also investigated whether age, sex, height, and handedness influenced the fingernail W/L ratio and transverse fingernail curvature. Results In women, fingernail W/L ratios were similar across all five fingers, and were lower than those in men. The highest value of transverse fingernail curvature was found in the thumb, followed by the index, middle, ring, and little fingers. Handedness and aging influenced transverse fingernail curvature, but not the fingernail W/L ratio. Fingernails were flatter on the dominant hand than on the non-dominant hand. The radius of transverse fingernail curvature increased with age, indicating that fingernails tended to flatten with age. Conclusions Our quantitative data on fingernail configuration can be used as a reference range for diagnosing various diseases and deformities of the fingernail, and for performing reconstructive or aesthetic fingernail surgery.

수-윤활용 플라스틱 베어링 개발에 관한 연구 (Development of Water-lubricated Plastic Bearings)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제39권6호
    • /
    • pp.235-243
    • /
    • 2023
  • This paper presents the fabrication process of water-lubricated plastic bearings. Plastic bearings require good mechanical properties and tribological properties as well as elasticity and shock resistance, especially when lubricated in dirty water conditions. In this study, sleeve-type plastic bearings are produced by winding a prepreg sheet, which primary contains nitrile rubber (NBR)-modified epoxy, self-lubricating fillers, and various types of lattice-structured reinforcing fibers such as carbon, Aramid, and polyethylene terephthalate. A thermosetting epoxy is chemically modified with NBR to impart elasticity and low-friction characteristics in water conditions. Experimental investigations are conducted to examine the mechanical and tribological characteristics of the developed bearing materials, and the results are compared with the characteristics of a commercial plastic bearing (Thordon SXL), well known as a water-lubricated bearing. A Thordon bearing (mainly composed of polyurethane) exhibits an extremely low load-bearing capacity and is thus only suitable for medium loading (1~10MPa). The tribological characteristics of the test materials are evaluated through Falex block-on-ring (LFW-1) friction and wear tests. The results indicate that friction exhibited by the carbon-fiber-reinforced NBR-10wt.%-modified epoxy composite material, incorporated with the addition of 20wt.% UHMWPE and 6wt.% paraffin wax, is lower than that of the Thorden bearings, whereas its wear resistance surpass that of Thorden ones. Because of these features, the load carrying capacity of the fabricated composite (>10MPa) is higher than that of the Thorden bearings. These results confirm the applicability of water-lubricated plastic bearing materials developed in this study.

고압하 추력중단장치의 변형거동 연구 (A Study on Deformation Behavior of Thrust Cut Off System under High Pressure)

  • 박성한;장홍빈;이환규;강문중;김재훈
    • 한국추진공학회지
    • /
    • 제9권4호
    • /
    • pp.89-95
    • /
    • 2005
  • 추력중단장치는 연소관 전방 도움부의 구멍에 설치되며 연소관에 내압 작용 시 쐐기가 강제로 이탈되면 스냅링과 마개가 순차적으로 이탈된다. 이 장치의 변형거동을 이해하기 위하여 수압 구조시험 및 구조해석을 수행하여 그 결과를 비교분석하였다. 추력중단 구멍에 설치되는 분할선의 개수를 대칭적으로 증가시키면 추력중단장치의 기밀성능은 크게 향상된다. 부품간의 마찰계수가 증가하면 추력중단 장치의 이탈압력이 증가하며 패기가 강제 이탈된 상태에서도 스냅링 및 마개의 이탈이 불가능한 임계 마찰계수가 존재한다. 스냅링은 마찰계수가 작으면 반경 방향으로 수축하여 이탈하며 마찰계수가 크면 상당한 소성 변형을 받은 후에도 이탈되지 않는 거동을 보인다.

원전 냉각수 취수용 GFRP관의 장기관변형 예측 (Long-term Ring Deflection Prediction of GFRP Pipe in Cooling Water Intake for the Nuclear Power Plant)

  • 김선희;박준석;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제3권3호
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, underground pipes are utilized in various fields of applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. Most of pipes are installed for long-term purposes and they should be safely installed in consideration of installation conditions because there are unexpected various terrestrial loading conditions. In this paper, we present the result of investigation pertaining to the structural behavior of glass fiber reinforced thermosetting polymer plastic (GFRP) flexible pipes buried underground. The mechanical properties of the GFRP flexible pipes produced in the domestic manufacturer are determined and the results are reported in this paper. In addition, ring deflection is measured by the field tests and the finite element analysis (FEA) is also conducted to simulate the structural behavior of GFRP pipes buried underground. From the field test results, we predicted long-term, up to 50 years, ring deflection of GFRP pipes buried underground based on the method suggested by the existing literature. It was found that the GFRP flexible pipe to be used for cooling water intake system in the nuclear power plant is appropriate because 5% ring deflection limitation for 50 years could be satisfied.

알루미늄 링롤재의 급냉 및 요소제거 후 잔류응력의 유한요소해석 (Finite Element Analysis of Residual Stress after Quenching and Element Removal of A1 Ring Rolls)

  • 박성한;구송회;이방업;조원만;은일상
    • 한국추진공학회지
    • /
    • 제2권1호
    • /
    • pp.31-40
    • /
    • 1998
  • 고강도 알루미늄 대형 링롤재의 급냉 및 요소제거 후 발생하는 잔류응력을 2차원 및 3차원 유한요소 해석하였고, 3단계 절단법에 의해 측정된 변형율과 ABAQUS의 요소제거 기능을 이용한 해석값을 직접 비교하였다. 급냉후 잔류응력 해석결과는 2단 과시효후 측정값과 비슷한 경향을 보였으나 그 절대값의 차이가 크게 나타났다. 이는 링 시편의 높이가 작아 측정값이 부정확하였기 때문이며, 링의 높이를 증가시켜 높이방향으로 균일한 응력분포를 갖도록 하면 그 차이가 감소될 것으로 판단된다. 잔류응력을 측정하는 3단계 절단 과정을 모사한 3차원 해석결과와 측정된 변형율을 직접 비교함으로써 실험과 해석의 정확성을 향상시킬 수 있도록 하였다. 이로부터 잔류응력이 내재하고 형상이 복잡한 대형 알루미늄 구조물의 기계가 공에 의한 변형을 정확히 예측할 수 있는 기반을 마련하였다.

  • PDF

엑스플리시트 시간 적분 유한요소법을 이용한 고속 성형 해석 (I) -마찰 및 관성 효과- (An Analysis of High Speed Forming Using the Explicit Time Integration Finite Element Method (I) -Effects of Friction and Inertia Force-)

  • 유요한;정동택
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-10
    • /
    • 1991
  • 본 연구에서는 고속 대변형 탄소성 변형 과정을 해석할 수 있는 프로그램(NET )을 개발하고 이것을 실린더 및 링 성형 문제에 적용하여 마찰 및 관성 효과가 변형 거동에 미치는 영향을 규명하여 보았다.