• 제목/요약/키워드: Plastic Displacement

검색결과 794건 처리시간 0.029초

An improved radius-incremental-approach of stress and displacement for strain-softening surrounding rock considering hydraulic-mechanical coupling

  • Zou, Jin-Feng;Wei, Xing-Xing
    • Geomechanics and Engineering
    • /
    • 제16권1호
    • /
    • pp.59-69
    • /
    • 2018
  • This study focused on the mechanical and hydraulic characteristics of underwater tunnels based on Mohr-Coulomb (M-C), Hoek-Brown (H-B) and generalized H-B failure criteria. An improved approach for calculating stress, displacement and plastic radius of the circular tunnel considering hydraulic-mechanical coupling was developed. The innovation of this study was that the radius-incremental-approach was reconstructed (i.e., the whole plastic zone is divided into a finite number of concentric annuli by radius), stress and displacement of each annulus were determined in terms of numerical method and Terzaghi's effective stress principle. The validation of the proposed approach was conducted by comparing with the results in Brown and Bray (1982) and Park and Kim (2006). In addition, the Rp-pin curve (plastic radius-internal supporting pressure curve) was obtained using the numerical iterative method, and the plastic radius of the deep-buried tunnel could be obtained by interpolation method in terms of the known value of internal supporting pressure pin. Combining with the theories in Carranza and Fairhurst (2000), the improved technique for assessing the reliability of the tunnel support was proposed.

Dynamic Analysis of 3 Point Bend Specimens under High Loading Rates

  • Han, Moon-Sik;Cho, Jae-Ung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권2호
    • /
    • pp.84-93
    • /
    • 2000
  • Computer simulations of the mechanical behavior of 3 point bend specimens with a quarter notch under impact load are performed. This validity is found to be identified by the experimental proof. The cases with various loading rates applied at the side of the specimen are considered. An elastoplastic von Mises material model is chosen. Gap opening displacement, reaction force, crack tip opening displacement and strain rate are also compared with rate dependent material(visco-plastic material). The stability during various dynamic load can be seen by using the simulation of this study. These differences of the cases with various loading rates are also investigated.

  • PDF

실험적 변위측정위치에 따른 구속효과 A2의 거동 (Experimental Behaviors of Constraint Effect A2 depending on Opening Displacement Measurement near Crack Front for SS400.)

  • 한민수;장석기
    • 대한금속재료학회지
    • /
    • 제46권6호
    • /
    • pp.345-350
    • /
    • 2008
  • The magnitude of constraint effect $A_2$ value was experimentally estimated by using crack tip opening displacement(CTOD) between elastic and plastic regions near crack tip front for CT specimen with $25.4t{\ss}{\AE}$ SS400 steel. The constraint effect, $A_2$ was dependent on specimen configuration and on the measured positions of CTOD near crack front. $A_2$ should be estimated using the opening displacement calculated within crack front plastic region. If not, it's not reliable to evaluate of constraint effect at crack growth initiation in this paper.

Determination of collapse safety of shear wall-frame structures

  • Cengiz, Emel Yukselis;Saygun, Ahmet Isin
    • Structural Engineering and Mechanics
    • /
    • 제27권2호
    • /
    • pp.135-148
    • /
    • 2007
  • A new finite shear wall element model and a method for calculation of 3D multi-storied only shear walled or shear walled - framed structures using finite shear wall elements assumed ideal elasto - plastic material are developed. The collapse load of the system subjected to factored constant gravity loads and proportionally increasing lateral loads is calculated with a method of load increments. The shape functions over the element are determined as a cubic variation along the story height and a linear variation in horizontal direction because of the rigid behavior of the floor slab. In case shear walls are chosen as only one element in every floor, correct solutions are obtained by using this developed element. Because of the rigid behavior of the floor slabs, the number of unknowns are reduced substantially. While in framed structures, classical plastic hinge hypothesis is used, in nodes of shear wall elements when vertical deformation parameter is exceeded ${\varepsilon}_e$, this node is accepted as a plastic node. While the system is calculated with matrix displacement method, for determination of collapse safety, plastic displacements and plastic deformations are taken as additional unknowns. Rows and columns are added to the system stiffness matrix for additional unknowns.

탄소성 접촉 해석법을 이용한 볼 압입시험의 시뮬레이션 (Simulation of Ball Indentation Process by Elasto-Plastic Contact Analysis)

  • 이병채;곽병만
    • 대한기계학회논문집
    • /
    • 제12권2호
    • /
    • pp.185-192
    • /
    • 1988
  • 본 논문에서는 접촉문제를 보다 정교하게 수식화 함으로써 효율적인 볼 압입 시험 시뮬레이션 방법을 제시하고 이를 실제에 적용하여 방법의 유용성을 보이고자 한다. 아울러 실험을 병행하여 결과를 비교함으로써 해석결과의 신뢰성을 검토한다.

강체요소법에 의한 철근 콘크리트 프리캐스트 대형판 접합부의 탄소성해석 (Elasto-plastic Analysis of Reinforced Concrete Precast Large Panel Connections by Rigid Element Method)

  • 박강근;김용태;권택진
    • 한국공간구조학회논문집
    • /
    • 제1권2호
    • /
    • pp.111-116
    • /
    • 2001
  • This paper is a study on the elasto-plastic analysis of reinforced concrete precast large panel connections by rigid element spring model. In the analysis of rigid element spring model, each collapsed part or piece of structures at limiting state of loading is assumed to behave like rigid bodies. The present author propose new elements for the improement and expansion of the rigid element spring model. In this study, it is proposed how the rigid element method can be applied to the elesto-plastic analysis of precat large panel connections. Some numerical results of analytical modeling and load displacement curves are shown.

  • PDF

전두동을 침습한 안와부 피부모양기형낭의 치험례 (A Clinical Experience of Direct Extension to Frontal Sinus of Orbital Dermoid Cyst)

  • 이상순;이형철
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.252-254
    • /
    • 2006
  • The dermoid cyst is the one of common space occupying orbital lesion. This lesion is regarded as a non-invasive tumor, but infrequently causes destruction of adjacent bony structure and displacement of adjacent tissue. We experienced a characteristic ovoid orbital dermoid cyst that occupied in the frontal sinus and causes displacement of the eyeball with well-defined lining. This 55-year-old male presented a mass in left orbit, which rapidly increased in size for past 12 months, and patient could not open left eyelid. We removed this tumor totally then reconstructed the orbital roof and frontal sinus with an iliac bone graft and polyethylene sheet(Medpor Newnan, USA). This patient was followed up for 12 months and patient obtained satisfactory result without any complication suck as recurrence or infection.

Elasto-plastic analysis using shell element considering geometric and material nonlinearities

  • Prasad, N. Siva;Sridhar, S.
    • Structural Engineering and Mechanics
    • /
    • 제6권2호
    • /
    • pp.217-227
    • /
    • 1998
  • An elasto-plastic finite element procedure using degenerated shell element with assumed strain field technique considering both material and geometric nonlinearities has been developed. This assumes von-Mises yield criterion, von-Karman strain displacement relations and isotropic hardening. A few numerical examples are presented to demonstrate the correctness and applicability of the method to different kinds of engineering problems. From present study, it is seen that there is a considerable improvement in the displacement valuse when both material and geometric nonlinearities are considered. An example of the spread of plastic zones for isotropic and anisotropic materials has been illustrated.

연약지반에서 CGP-앵커의 시공사례연구 (A Case Study on CGP Anchor of Open-Cuts in Soft Ground)

  • 천병식;양형칠;박신영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.621-628
    • /
    • 2002
  • Compaction Grouting Pack (CGP) Anchor which is composite anchor of bearing plus friction-type was chosen and executed for the open-cuts in soft ground. This paper presents an analysis of data from tests on composite-anchor by jacking force. The properties of composite-anchor was presented to be as follows , the maximum plastic displacement was 60 mm in abandoned coal fill deposit, the shear stress($\tau$) is expressed as $\tau$ = (equation omitted) kg/$\textrm{cm}^2$ in clayey silt.

  • PDF

2주형 다주교각의 연성도 및 소성힌지 영역에 관한 연구 (Assessment of Ductility and Plastic Hinge Region of Reinforced Concrete Multi-Column Bent)

  • 변순주;임정순
    • 한국방재학회 논문집
    • /
    • 제6권3호
    • /
    • pp.37-45
    • /
    • 2006
  • 다주교각의 횡방향 철근비에 따른 연성도 및 소성힌지 영역을 단주교각과 비교하여 평가하였다. 횡방향 철근비가 높을수록 연성도 증가는 뚜렷하며 다주교각의 경우 교축직각방향 거동시에는 단주보다 더 큰 연성도 증가를 보였다. 또한 횡철근 배근을 위한 소성힌지영역을 산정하였으며 목표연성도를 크게 할수록 횡구속 철근비의 증가와 함께 횡구속 되어야 하는 소성힌지영역 또한 높아져야함을 밝혔다. 다주교각의 방향별 거동에 따른 소성힌지 영역에는 차이가 있으며, 다주교각의 교축직각방향 거동시에는 모멘트 분포의 차이에 의해 보다 낮은 구간에서 소성변형을 보인다.