• 제목/요약/키워드: Plaster Cast

검색결과 39건 처리시간 0.026초

지역적 특성을 지닌 특성화 상점에 관한 연구 - 뉴욕 소호 지역을 중심으로 - (A Study on the Character Shops with Local Characteristics - Focused on the SoHo Area in New York City -)

  • 김명옥
    • 한국실내디자인학회논문집
    • /
    • 제37호
    • /
    • pp.80-87
    • /
    • 2003
  • Contemporary shops play an important role as a place to experience contemporary culture as well as sales and display techniques. This study is to suggest one of the prototypes of character streets consisting of characteristic shops through the analysis of the stores in the SoHo area in New York City. The study found that there are three kinds of characteristic shops preserving the cast-iron architectural environment in the SoHo area. In the first case, the interiors of the shops are partially renovated original lofts keeping decorative columns, white plaster walls and wooden floors. In the second case, the interiors are totally renovated leaving no old traces. This is achieved through wrapping columns and replacing old materials with new ones. In the third case, the interiors are renovated with the different approaches using mixed ideas and materials. The original columns exist but are transformed in this case. In the third case, shops tend to be extra large and complicated. The Prada shop in SoHo by Rem Koolaas is the best example of this case. This shop is the conceptual city, theater and avant-garde museum itself, that is, the place of experiencing contemporary culture.

주상골 골절의 수술적 치험례 (Treatment of Carpal Scaphoid Fracture)

  • 백원진;서재성;안종철;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제3권1호
    • /
    • pp.361-366
    • /
    • 1986
  • 1985년 3월부터 1986년 6월까지 영남대학교 의과대학 정형외과학교실에서 10예의 주상골 골절환자에 나사를 사용하여 치료하였으며 그 결과를 요약하면 다음과 같다. 10예중 신선골절이 2예였고 불유합 골절이 8예이었다. 불유합 골절의 경우 수상후 수술시까지 기간이 최단 5개월에서 5년이었다. 수술후 고정기간은 평균 4주였으며 4주후 능동적 운동을 시행하여 고정기간의 단축으로 관절운동 회복은 매우 양호하였다. 골유합을 보인 사기는 8예에서 3개월에서 9개월 사이였으며 2예에서는 9개월 후에도 방사선상 골절선은 볼 수 있었다. 골절선이 남아있는 경우도 임상적으로는 증세의 호전(동통, 관절 운동)을 나타내었다.

  • PDF

기하학 기술을 이용한 인레이/온레이의 외면 모델링 (An External Surfaces Modeling of Inlay/onlay Using Geometric Techniques)

  • 유관희;하종성
    • 정보처리학회논문지A
    • /
    • 제12A권6호
    • /
    • pp.515-522
    • /
    • 2005
  • 본 논문에서는 부분적으로 파손된 치아의 수복에 사용되는 인레이/온레이 인공치아를 효과적으로 모델링하는 기법을 제안한다. 인레이/온레이는 지대치에 부착되는 내면과 밖으로 들어나는 외면으로 구성된다. 내면은 지대치와의 밀착력을 확보하기 위하여 지대치의 삭제된 표면의 확장된 부분으로 Minkowski sum을 이용하여 모델링된다. 외면을 모델링하기 위해서는 표준치아 모델, 환자 치아 석고모형을 스캔한 메쉬 자료, 환자 치아교합을 측정한 FGP(functionally guided plane) 등 세 가지 정보와 DMFFD(direct manipulation free-form deformation)[19]과 MWD(multiple wires deformation)[17]의 3D 메쉬 변형 기술들을 이용한다. 표준치아 모델은 외면의 기본적인 형태를 결정하기 위하여 사용되는 반면 석고모형 데이터와 FGP는 환자 치아 인접면과 교합면마다 약간 다르지만 정확한 기능에 매우 중요한 고유 특성을 반영하기 위해 사용되는 정보이다. 이러한 정보들을 입력으로 DMFFD 기법과 MWD 기법을 각각 적용하여 인레이/온레이 인접면과 교합면을 메쉬 자료로 자동으로 생성해낸다. 연구된 기법은 치과의사에 의한 요구사항을 반영하여 생성된 메쉬 모델을 가시화하면서 보다 정확하게 인레이/온레이를 디자인할 수 있도록 구현되었다.

신체동작에 따른 상지형태변화에 관한 피복인간공학적 연구 - 전방수직동작과 측방수직동작을 중심으로 - (A Clothing-Ergonomics Study on the Variation of Upper Arm Skin Surface According to Arm Movements - on the arm movements to the vertical direction in front and in side -)

  • 김혜경;박은주;전은경
    • 한국의류학회지
    • /
    • 제13권1호
    • /
    • pp.49-58
    • /
    • 1989
  • A clothing-erogonomics study was performed to investigate the difference of the upper arm skin skin surface and the relationship among the three aspects of upper arm (height of sleeve rap, sleeve width and armhole girth) by changing arm movements. Plaster cast was used for this experimental research. Arm movements consist of 9 types; just carmly standing on ($0^{\circ}$), and each 4 types ($45^{\circ},\;90^{\circ},\;135^{\circ},\;180^{\circ}$) to the vertical direction in front and in side. The results were as follows; 1) As the arm-movement angle increased, the height of sleeve cap decreased and that ratio was largest in the portion A-B3. 2) The steeve width was enlarged with the increment of movement angle in all portions of upper arm except B1-B5. 3) As increasing the movement angle, the whole armhole girth decreased and the ratio o(front armhole girth (F-A) was larger than that of back. 4) In the vertical direction in front, the height o( the sleeve caps was larger, the sleeve widths were smaller than in the vertical direction in side in all movement types, but there was no significant difference in arm-hole girth between the two cases. 5) There were significantly negative relationships between measurements in height of sleeve cap and those in sleeve width, and also between those in height of sleeve cap and in arm-hole girth. And significantly positive relationships were found between neasurements in height of sleeve cap and those in arm-hole girth.

  • PDF

인상채득 방법이 임플란트 보철 작업모형의 정확도에 미치는 영향 (EFFECT OF IMPRESSION TECHNIQUES ON ACCURACY OF MASTER CASTS FOR IMPLANT PROSTHESES)

  • 홍은희;한동후
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.445-454
    • /
    • 1994
  • Osseointegrated implant prostheses are to provide normal function without compromising the unique interaction between the tissue and the implant. The essential requirement for the osseointegrated implant prostheses is passive fit of abutment. Therefore, the impression must be accurate and reproduciable since the resultant master cast precisely duplicates the clinical condition. The purpose of this study was to compare the accuracy of the master casts obtained from five impression techniques. Group 1 : To take impression with indirect technique and Impregum F. Group 2 : To take impression with unsplinted direct technique and Impregum F. Group 3 : To take impression with splinted direct technique and Impregum F. Group 4 : To take impression with unsplinted direct technique and Xanthano. Group 5 : To take impression with splinted dierct technique and Xanthano. The results were as follow : 1. In taking impression of Impregum F, there was no significant difference between to use of indirect technique and unsplinted direct technique.(p<0.05) 2. Unsplinted direct technique with Impregum F is less accurate than splinted direct technique with Impregum F or Xanthano and unsplinted direct technique with Xanthano.(p<0.05). 3. There was no significant difference between splinted direct technique with Impregum F and unsplinted direct technique with Xanthano.(p<0.05) 4. Splinted direct technique reproduce more accurate than unsplinted direct technique.(p<0.05) 5. Impression plaster produced less distortion than polyether.(p<0.05) As a result, splinted direct technique with Xanthano was the most accurate technique. As a result, splinted direct technique with Xanthano was the most accurate technique in this study. In addition to dimensinal changes in the materials used, positional errors were also attributed to the mechanical components used in the transfer porocess. Although the errors measured were relatively small, this study demonstrates the potential for distortions with the transfer technique used. Further study is indicated that ?the technique will be able to reproduce the intraoral relationship of implant fixtures reliably and predictably.

  • PDF

발목부상을 당한 석고환자의 발꿈치뼈·목말받침돌기 관찰을 위한 Broden 촬영법 연구 (Broden photographing method for Calcaneus Subtentaculum tali observation of Ankle plaster patient)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.107-112
    • /
    • 2013
  • 발목 병변을 관찰하는 단순 방사선촬영은 여러 가지가 있다. 그 중에서 Ankle Broden법은 발꿈치뼈(Calcaneus) 및 발목뼈(Ankle Joint)의 결합상태와 발목뼈의 발꿈치뼈 골절(Calcaneus Fracture), Subtentaculum Tali Frature를 관찰하기 위하여 촬영을 한다. 이 촬영법은 전 후면과 측면뿐 아니라, 사면 상(oblique view)이나 축 상(axial view)의 촬영을 하며 잦은 부상이 발생하는 목말뼈 발꿈치뼈간, 발꿈치뼈 발배뼈간 결합상을 보기 위해 주로 촬영을 한다. 본 연구는 석고처치 환자들은 발목관절이 영상에 잘 묘출되기가 어렵기 때문에 발목뼈 사이의 관계 및 연부조직의 구조적 변화와 Subtalar joint, Calcaneus Fracture, Subtentaculum Tali Frature에 따른 목말뼈 발꿈치뼈의 골 결합 (talocalcaneal coalition)을 관찰하기 위한 Harris-Beath View($30^{\circ}{\sim}55^{\circ}$) 촬영 시 평가에 유용한 발목뼈의 결합상을 얻을 수 있는 각도를 알아보고자 하였다. 연구의 진행은 40명의 환자에게서 획득한 영상을 평가하였으며, 평가결과 $25^{\circ}$의 촬영상은 목말밑 관절(subtalar joint)이 열려져 분리되지 않았고 또한, Subtentaculum Tali Frature에 중복되어 보였다. $30^{\circ}$의 촬영상은 발꿈치뼈 골절(Calcaneus Fracture), Subtentaculum Tali Frature, 목말밑관절(subtalar joint과 후방 관절면의 앞부분이 가장 잘 나타나고 Calcaneo Navicularcoalition, Talocal Canealcoalition, Naviculo Cuneiform coalition의 결합상태가 명확하게 보였다. $35^{\circ}$의 촬영상은 목말밑관절(subtalar joimt), 목말뼈(talus), 발뒤꿈치뼈의 뒤쪽관절면이 명확하고 발목발꿈치관절(talocalcaneal joint)의 분리정도가 좋고 발목뼈굴(sinus tarsi)이 넓게 나타나며 좋은 평가가 되었다. $45^{\circ}$영역에서는 연부조직과 석고 분리를 판별할 수 있었고 가쪽복사와 뼈 밀도가 명확하게 보였다. $35^{\circ}$에 비해 발꿈치뼈(Calcaneus)이 분리되었지만 영상이 왜곡되어 보였다. Calcaneus, Subtentaculum Tali Frature는 $25^{\circ}$에서 $1.20{\pm}0.414$, $30^{\circ}$에서는 $2.47{\pm}0.516$, $35^{\circ}$에서는 $2.87{\pm}0.352$, $45^{\circ}$에서는 $2.27{\pm}0.458$로 나타났고 통계적으로 유의한 차이가 나타났다(p<0.05). 왜곡의 정도를 포함시키면 $30^{\circ}$영역의 왜곡이 적게 나타났고, $40^{\circ}$ 영역은 심한 왜곡현상을 보였다. 따라서 Ankle(Broden)촬영에서 $30{\sim}35^{\circ}$상이 가장 좋은 영상이었으며, $30{\sim}40^{\circ}$상에서는 Calcaneus Fracture, Subtentaculum Tali Frature의 진단에 가장 좋은 영상을 묘출하였다.

치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구 (Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation)

  • 박주희;설정환;이준재;이승표;임영준
    • 구강회복응용과학지
    • /
    • 제34권2호
    • /
    • pp.104-115
    • /
    • 2018
  • 목적: 본 연구는 현재 시판되고 있는 구강스캐너를 사용하여 구강스캐너 정확도 평가를 위해 국제표준이 제안하고 있는 모형의 스캔이미지 획득이 가능한 지 분석하고, 이를 통해 표준모델이 가지고 있는 문제점을 파악하는 데 있다. 연구 재료 및 방법: ISO12836과 ANSI/ADA no.132에서 규정하는 국제표준을 참고하여 3D 프린터기를 이용하여 모델을 제작하였으며, 모델스캐너와 두 가지 구강스캐너를 이용하여 스캔을 하였다. 스캔이미지 획득 정도를 3등급으로 분류하여 스캐너의 성능을 비교하였으며, 모델 표면의 상태에 따른 이미지 획득 능력도 비교하였다. 결과: 모델 스캐너가 모든 모델에서 가장 우수한 이미지를 얻을 수 있었으며 TRIOS3는 둥근 형태의 구조물, CS3500은 각진 형태의 구조물에 대한 이미지 재현이 좋은 결과를 보였다. 표준 모델의 표면상태에 따른 스캔이미지 재현에서는 초경석고 모델이 스캐너 종류와 관계없이 가장 우수하였다. 3D 프린팅 모델의 경우, 표면에 파우더 처리를 한 모델에서 가장 우수한 스캔이미지를 얻을 수 있었다. 결론: ISO12836과 ANSI/ADA 132의 표준모델의 경우, 구강스캐너의 field of view (FOV)를 벗어나는 구조물을 스캔할 때 서로 다른 면인 것을 구분하는 기준점이 존재하지 않게 되면 연속적인 스캔 및 정합과정에서 정확한 이미지를 나타내지 못한다는 것을 알 수 있었다. 그러므로 단순한 패턴의 반복과 대칭구조를 가지지 않는 새로운 표준모델이 필요하다고 여겨진다.

제한 절개를 통한 관혈적 정복 및 내고정술을 이용한 경골 Pilon 골절의 치료 (Limited Open Reduction and Internal Fixation of the Tibial Pilon Fractures)

  • 강충남;김종오;김동욱;고영도;고상훈;유재두;황준호
    • 대한족부족관절학회지
    • /
    • 제1권2호
    • /
    • pp.102-111
    • /
    • 1997
  • 저자들은 1993년 9월부터 1996년 5월까지 본원 정형외과에 입원하여 Pilon 골절로 치료받고 1년 이상 추시 가능하였던 19례(18명)를 대상으로 다음과 같은 결론을 얻었다. 1. Ovadia와 Beals의 분류상 제1형이 2례, 제2형이 3례, 제3형이 10례, 제4형이 1례, 제5형이 3례였고, 제3형이 53%로 가장 많았으며, 교통사고와 추락손상 등 고에너지 손상에 의한 골절이 16례로 전체의 약 84%를 차지하였다. 2. 손상의 정도가 비교적 적은 제1형과 제2형에서는 모두 양호 이상의 임상결과를 나타내었으며, 제4형과 5형에서는 손상의 정도가 심하고 이로인한 정확한 정복의 어려움으로 인해 보통 이하의 성적을 나타내었다. 3. 합병증은 외상후 관절염이 6례로 가장 많았으며 손상정도가 심한 3형 이상에서 정확한 정복이 이루어지지 않은 경우에 발생하였으며, 방사선학적 평가가 보통이하였던 제3형 3례에서 부정 유합이 발생하였으나 임상결과와의 연관성은 없었다. 4. 저자들은 제한된 관혈적 정복 및 내고정술로 연부조직의 합병증을 현격히 줄일 수 있었으며, 손상의 정도가 적고 정확한 정복이 가능한 경우, Pilon 골절의 좋은 치료 술식의 하나라고 사료된다.

  • PDF

산업연관표(2003년)를 활용한 산업별 CO2 배출 원단위 분석 (Analysis of CO2 Emission Intensity per Industry using the Input-Output Tables 2003)

  • 박필주;김만영;이일석
    • 자원ㆍ환경경제연구
    • /
    • 제18권2호
    • /
    • pp.279-309
    • /
    • 2009
  • 산업에서 발생되는 온실가스를 줄이기 위해서는 각 산업별 온실가스 발생량을 정확히 예측해야 한다. 이에 본 연구에서는 2003년 산업연관표와 에너지 사용량 통계자료를 기초로 401개 산업별 직 간접 $CO_2$ 원단위를 산출하고 이를 활용하는 방안을 검토하였다. 본 연구는 국내에 없는 일부 데이터 대신 해외 데이터 사용, 석유정제부문에 대한 분배 문제, 카본뉴트럴 측면에서 재검토 필요성, 폐기물처리 부문 과정의 일부 미고려 등에 따른 결과의 한계를 가지고 있다. 그럼에도 불구하고 부산물로 얻어지는 코크스로가스나 철강계 가스, 자원순환 관점에서 주목받고 있는 폐기물 영향까지를 고려한 401개 상세 산업별 직 간접 $CO_2$ 원단위를 산출했다는 측면에서 의미가 있다. 산업별 $CO_2$ 배출 원단위 분석 결과를 살펴보면, 간접 $CO_2$ 원단위가 크게 나타난 대표적인 산업으로는 조강, 레미콘, 선재 및 궤조, 주철물, 철근 및 봉강 산업이다. 이들 산업은 직접 $CO_2$ 원단위가 큰 산업에서 생산된 원료물질을 이용하여 제품을 생산하고 있다. 직접 $CO_2$ 배출 원단위가 크게 나타난 대표적인 산업으로는 시멘트, 선철, 석회 및 석고 제품, 석탄화합물 등 자연으로부터 채취한 원광석 등을 이용하여 다른 산업에 유용한 원료물질로 정제하는 산업이었다. 본 연구 결과는 산업별 특성이 반영된 저감 목표치 산정, $CO_2$ 저감정책별 감축 잠재량 산정, 기업의 $CO_2$ 배출량 수준 파악 및 저감 목표량을 설정할 때 유용하게 활용될 수 있다. 그 밖에도 국내에서 활발히 연구되고 있는 환경경제통합계정, 산업별 물질흐름분석 분야에서 널리 응용될 수 있을 것이다.

  • PDF