• 제목/요약/키워드: Plasma-Solution System

검색결과 122건 처리시간 0.027초

포화 컬럼실험에서 이온강도 변화 및 유기물질 출현에 의한 PVP로 코팅된 은나노 입자의 거동 연구 (Transport behavior of PVP (polyvinylpyrrolidone) - AgNPs in saturated packed column: Effect of ionic strength and HA)

  • 허지용;한종훈;허남국
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.263-270
    • /
    • 2016
  • Recent Engineered nanoparticles were increasingly exposed to environmental system with the wide application and production of nanomaterials, concerns are increasing about their environmental risk to soil and groundwater system. In order to assess the transport behavior of silver nanoparticles (AgNPs), a saturated packed column experiments were examined. Inductively coupled plasma-mass spectrometry and a DLS detector was used for concentration and size measurement of AgNPs. The column experiment results showed that solution chemistry had a considerable temporal deposition of AgNPs on the porous media of solid glass beads. In column experiment, comparable mobility improvement of AgNPs were observed by changing solution chemistry conditions from salts (in both NaCl and $CaCl_2$ solutions) to DI conditions, but in much lower ionic strength (IS) with $CaCl_2$. Additionally, the fitted parameters with two-site kinetic attachment model form the experimental breakthrough curves (BTCs) were associated that the retention rates of the AgNPs aggregates were enhanced with increasing IS under both NaCl and $CaCl_2$ solutions.

유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과 (Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure)

  • 유영효;엄환섭;박경순;최은하
    • 한국진공학회지
    • /
    • 제22권2호
    • /
    • pp.55-65
    • /
    • 2013
  • 본 연구에서는, 동시에 넓은 면적을 조사할 수 있는 형태의 유전체 장벽 방전을 이용한 대기압 면방전 플라즈마 발생장치를 이용하여 곰팡이의 살균 실험을 수행하였다. 실험에 사용한 면방전 플라즈마 발생장치의 파워는 사인파 교류전원을 이용하였으며, 1.4~2.3 kV의 방전전압을 가진다. 또한, 유전체 전기용량의 특성으로 인하여 전압과 전류의 위상차는 약 80도를 갖는다. 생물시료에 미치는 온도의 영향은 공랭식 쿨러를 사용하여 유전체의 열을 배출함으로써 최소화 하였으며, 시료의 온도는 온도측정장치를 사용하여 쿨러(Cooler) 작동 시 최대 10분간 플라즈마를 발생시켜도 37도가 넘지 않음을 확인하였다. 플라즈마에서 생성되는 활성종중 오존($O_3$)의 양은 플라즈마 발생부로부터 1 cm 이내에서 약 25~30 ppm이 측정되었으며, 150 cm 떨어진 지점에서도 5 ppm 정도 측정되었다. 그에 비해 일산화질소(NO)나 이산화질소($NO_2$)는 거의 검지되지 않음을 확인하였다. 증류수 속에 담긴 빵 곰팡이 포자를 면방전 플라즈마 발생장치로 처리하였을 때, 포자의 발아율은 처리시간 및 출력파워가 증가함에 따라 급격히 감소하였으며, MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) 측정법을 통해 분석한 미토콘드리아 활성도도 처리시간과 출력파워에 비례하여 감소함을 보았다. 반면 포자를 Vogel's minimal 배양액에 넣고 플라즈마 처리를 하면, 앞의 실험과 달리 살균효과가 미비함을 보였는데, 이를 통해 포자를 둘러싸고 있는 환경이 플라즈마의 살균효과에 영향을 미치는 것으로 보여진다. 본 연구를 통하여 유전체 장벽을 이용한 면방전 플라즈마 발생장치는 플라즈마 제트(jet)와는 달리 직접적인 접촉 없이도 미생물 살균이 가능하다는 것을 보여주었으며, 이는 면방전 플라즈마 발생장치로부터 발생하는 활성종들이 곰팡이와 같은 미생물의 비활성화에 주요역할을 하기 때문이라고 본다.

Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors

  • Heo, Eun-Yeong;Ko, Young-Il;Bae, Jin-Seok
    • 한국염색가공학회지
    • /
    • 제21권5호
    • /
    • pp.51-57
    • /
    • 2009
  • Since heavy metal pollution is a significant global environmental problem and very dangerous to human health, the improved methods for detecting heavy metals are required recently. Colorimetric chemosensors are now considered as one of the most effective analytical method used in the environment monitoring. New direct dyes having the function of colorimetric chemosensors were synthesized. When metal ions such as $Al^{3+}$, $Ca^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Cu^{2+}$, $Fe^{2+}$, $Fe^{3+}$, $Hg^{2+}$, $Li^+$, $Mg^{2+}$, $Na^+$, $Ni^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ were added each solution of new direct dyes, the color of solution was changed and can be easily detected with naked eyes without expensive experimental equipment such as atomic absorption spectrometer (AAS) or inductively coupled plasma?mass spectrometer (ICP-MS). The new benzidine analogues were diazotized and reacted with couplers such as H-acid, J-acid, Chromotropic acid, Nevill-winther acid and gamma acid to synthesize new direct dyes. The structures of the new direct dyes were confirmed by high resolution mass spectrometer (FAB ionization) and evaluated with UV-Vis spectroscopy. The UV-VIS spectroscopy was measured for the dye solutions by adding various concentrations of metal ions. It was observed that the absorbance in UV-Vis spectra was changed as the heavy metal ions were added.

SYMMETRY REDUCTIONS, VARIABLE TRANSFORMATIONS AND EXACT SOLUTIONS TO THE SECOND-ORDER PDES

  • Liu, Hanze;Liu, Lei
    • Journal of applied mathematics & informatics
    • /
    • 제29권3_4호
    • /
    • pp.563-572
    • /
    • 2011
  • In this paper, the Lie symmetry analysis is performed on the three mixed second-order PDEs, which arise in fluid dynamics, nonlinear wave theory and plasma physics, etc. The symmetries and similarity reductions of the equations are obtained, and the exact solutions to the equations are investigated by the dynamical system and power series methods. Then, the exact solutions to the general types of PDEs are considered through a variable transformation. At last, the symmetry and integration method is employed for reducing the nonlinear ODEs.

플라즈마 전해 산화 코팅에 있어서 알루미늄 합금 모재 성분의 물리적, 결정학적 영향 II. PEO 층의 결정상 분석 (Effect of Al Alloy Composition on Physical and Crystallographical Properties of Plasma Electrolytic Oxidized Coatings II. Crystallographic Analysis of PEO Layer)

  • 김배연;이득용;신민철;신현규;김병곤;김성엽;김광엽
    • 한국세라믹학회지
    • /
    • 제47권4호
    • /
    • pp.283-289
    • /
    • 2010
  • Physical properties of Plasma electrolytic oxidized 8 different kinds of Al alloys, A-1100, A-2024, A-5052, A-6061, A-6063, A-7075, ACD-7B and ACD-12 were investigated. The electrolyte for PEO was $Na_2SiO_3$ and NaOH and some alkali earthen metal salts system solution. $\eta$-alumina, as well as $\gamma$-alumina, was main crystal phase, which were ever reported. Also, $Al_{4.95}Si_{1.05}O_{9.52}$ was found only in this research. So we can conclude that the process conditions of PEO apparatus and composition and concentration of its electrolyte affects crystal structure and physical properties of PEO layers much more than the compositions of Al alloy.

공기-플라즈마 방전 시스템에서 화학적 활성종의 생성에 대한 연구 (Study on the Generation of Chemically Active Species using Air-plasma Discharging System)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.401-408
    • /
    • 2012
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and air flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the increased of the 2nd voltage (4 kV to 15 kV), RNO degradation, $H_2O_2$ and $O_3$ generation were increased. The conductivity of the solution was not influencing the RNO degradation and $H_2O_2$ and $O_3$ generation. The effects pH was not high on RNO degradation. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

Determination of Li by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.;Chung, Bag S.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.427-434
    • /
    • 1995
  • Inductively coupled plasma mass spectrometry combined with the isotope dilution method is used for the determination of lithium. The isotope dilution method is based on the addition of a known amount of enriched isotope (spike) to a sample. The analyte concentration is obtained by measuring the altered isotope ratio. The spike solution is calibrated through so called reverse isotope dilution with a primary standard. The spike calibration is an important step to minimize error in the determined concentration. It has been found essential to add spike to a sample and the primary standard so that the two isotope ratios should be as dose as possible. Since lithium is neither corrosive nor toxic, lithium is used as a chemical tracer in the nuclear power plants to measure feedwater flow rate. 99.9% $^7Li$ was injected into a feedwater line of an experimental system and sample were taken downstream to be spiked with 95% $^6Li$ for the isotope dilution measurements. Effects of uncertainties in the spike enrichment and isotope ratio measurement error at various spike-to-sample ratios are presented together with the flow rate measurement results in comparison with a vortex flow meter.

  • PDF

건식플라즈마 표면처리법에 의한 마그네슘 합금의 내식특성 향상 (A Study on the Enhancement of Corrosion Resistance of Magnesium Alloy by Dry Plasma Process)

  • 윤용섭
    • 해양환경안전학회지
    • /
    • 제17권2호
    • /
    • pp.155-160
    • /
    • 2011
  • 현재 지구온난화 등의 환경문제로 인해 각종 산업분야에서 정량화에 대한 요구가 증대되어 해양산업에도 그 수요가 증가하고 있는 실정이다. 따라서 본 연구에서는 차세대 경량화 재료인 마그네슘이 활용되기 위해서 반드시 극복해야할 가장 중요한 특성인 내식특성에 대하여 고찰하고, 그 내식특성 향상을 위한 마그네슘 박막의 Morphology나 결정배향성의 영향을 해명하고자 하였다. 실험결과로부터 제작한 Mg 박막의 전기화학적 내식특성은 Ar 가스압이 높은 조건에서 제작한 막일수록 내식특성이 우수하였다. 이러한 경향은 표면 및 단면의 Morphology와 결정배향성과의 상관관계를 통하여 설명 가능하였다.

생체 삽입형 유연한 마이크로 전극의 제작 및 평가 (Fabrication and Evaluation of the Flexible and Implantable Micro Electrode)

  • 백주열;권구한;이상운;이기암;이상훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권2호
    • /
    • pp.93-99
    • /
    • 2006
  • In this paper, we fabricated and evaluated polydimethylsiloxane(PDMS)-based flexible and implantable micro electrodes. The electrode patterning was carried out with the photolithography and chemical etching process after e-beam evaporation of 100 ATi and 1000 A Au. The PDMS substrate was treated by oxygen plasma using reactive ion etching(RIE) system to improve the adhesiveness of PDMS and metal layers. The minimum line width of fabricated micro electrode was 20 $\mu$m. After finished patterning, we did packaging with PDMS and then brought up the electrode's part about 40 $\mu$m with gold electroplating. The Hank's balanced salt solution(HBSS) test was carried out for 6 month for endurance of fabricated micro electrode. We carried out in-vivo test for the evaluation of biocompatibility by implanting electrodes under the ICR mouse skin for 42 days.

Fabrication of Prototype vuv Spectrometer & Liquid Target System Containing Hydrogen

  • 이윤만;김재훈;김진곤;안병남
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.586-586
    • /
    • 2012
  • The vuv spectrometer for ITER main plasma measurement is designed as a five-channel spectral system. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The overall system performance was verified by comparing the measured spectral resolutions with the calculated spectral resolutions. And we also have developed liquid jet target system. This study is about a neutron generator, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the ones operating at high neutron fluxes and maintained relatively thin with no need for water cooling. In this study, liquid target containing hydrogen has been developed and tested.

  • PDF