• Title/Summary/Keyword: Plasma test

Search Result 1,362, Processing Time 0.039 seconds

Determiniation and Validation of Alibendol using High Pressure Liquid Chromatography in Human plasma (고속액체크로마토그라피법을 이용한 사람 혈장 중 알리벤돌(Alibendol)의 정량 및 검증)

  • Song, Hyun-Ho;Yu, Ji-Young;Kim, Bo-Gyeom;Park, Hyeon-Ju;Choi, Kwang-Sik;Kwon, Young-Ee
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.295-299
    • /
    • 2010
  • The aim of this study was to develop and validate for determination of alibendol in human plasma by HPLC method. After precipitation of 500 ${\mu}l$ plasma samples by 50% methanol 50 ${\mu}l$ and 60% perchloric acid 30 ${\mu}l$ and the supernatant 50 ${\mu}l$ was injected into HPLC. The assay was performed isocratically using 10 mM potassium phosphate (pH 3.0) and acetonitrile (80 : 20, v/v) as mobile phase. The $C_{18}$ column (particle size $3.5{\mu}m$, $4.6{\times}50$ mm, Zorbax Eclipse) was used as a solid phase. The mobile phase was delivered at a flow-rate of 1.7 ml/min, detection was by ultraviolet absorption at 232 nm and concentrations were calculated on the basis of peak areas. In these conditions, alibendol can be separated from ethylparaben, the internal standard, and endogenous substances. The retention times of alibendol and ethylparaben were just about 2.6 and 3.5 minutes, respectively. This rapid HPLC method was validated by examining the precision and accuracy for inter- and intra-day analysis. The standard curve was linear ($R^2$=1.0000) over the concentration range of 0.05~20 ${\mu}g$/ml. The inter-day relative standard deviation (R.S.D.) and accuracy were 0.2~12.2% and 94.4~101.2% (82.7% at the lower limit of quatitation). The intra-day R.S.D. and accuracy were 0.1~11.8% and 98.8~102.5%, respectively. The method was successfully applied to the determination of alibendol in plasma for a pharmacokinetic study.

The Evaluation of Surface and Adhesive Bonding Properties for Cold Rolled Steel Sheet for Automotive Treated by Ar/O2 Atmospheric Pressure Plasma (대기압 Ar/O2 플라즈마 표면처리된 자동차용 냉연강판의 표면특성 및 접착특성평가)

  • Lee, Chan-Joo;Lee, Sang-Kon;Park, Geun-Hwan;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.4
    • /
    • pp.354-361
    • /
    • 2008
  • Cold rolled steel sheet for automotive was treated by Ar/$O_2$ atmospheric pressure plasma to improve the adhesive bonding strength. Through the contact angle test and calculation of surface free energy for cold rolled steel sheet, the changes of surface properties were investigated before and after plasma treatment. The contact angle was decreased and surface free energy was increased after plasma treatment. And the change of surface roughness and morphology were observed by AFM(Atomic Force Microscope). The surface roughness of steel sheet was slightly changed. Based on Taguchi method, single lap shear test was performed to investigate the effect of experimental parameter such as plasma power, treatment time and flow rate of $O_2$ gas. Results shows that the bonding strength of steel sheet treated in Ar/$O_2$ atmospheric pressure plasma was improved about 20% compared with untreated sheet.

A Study on the Properties of the Dual-mode Plasma Torch System for Melting the Non-conductive Waste (비전도성 폐기물 용융처리를 위한 혼합형 플라즈마토치 시스템 특성 연구)

  • Moon, Young-Pyo;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.73-80
    • /
    • 2016
  • The preliminary test for the dual mode plasma torch system was carried out to explore the operation properties in advance. The dual mode plasma torch system that is able to operate in transferred, non-transferred, or dual mode is very adequate for melting the mixed wastes including nonconductive materials such as concrete, asbestos, etc. since it exploits both the high efficiency of heat transfer to the melt in transferred mode and stable operation in non-transferred mode. Also, system operation including restarting is reliable and very easy. A stationary melter with a refractory structure was designed and manufactured considering the melting behavior of slags to minimize the refractory erosion. The power supply for the dual mode plasma torch system built with high power insulated gate bipolar transistor (IGBT) modules has functions for both current control and voltage control and is sufficient to suppress the harmonics during the operation of the plasma torch. The power supply provides two different voltages for transferred operation and non-transferred. It is confirmed that the operation voltage in transferred is always higher than non-transferred. The dual mode plasma torch system was successfully developed and is under operation for a melting experiment to optimize operation data.

Fuzzy-PID controller for motion control of CFETR multi-functional maintenance platform

  • Li, Dongyi;Lu, Kun;Cheng, Yong;Zhao, Wenlong;Yang, Songzhu;Zhang, Yu;Li, Junwei;Wu, Huapeng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2251-2260
    • /
    • 2021
  • The motion control of the divertor maintenance system of the China Fusion Engineering Test Reactor (CFETR) was studied in this paper, in which CFETR Multi-Functional Maintenance Platform (MFMP) was simplified as a parallel robot for the convenience of theoretical analysis. In order to design the motion controller of parallel robot, the kinematics analysis of parallel robot was carried out. After that, the dynamic modeling of the hydraulic system was built. As the large variation of heavy payload on MFMP and highly nonlinearity of the system, A Fuzzy-PID controller was built for self-tuning PID controller parameters by using Fuzzy system to achieve better performance. In order to test the feasibility of the Fuzzy-PID controller, the simulation model of the system was built in Simulink. The results have showed that Fuzzy-PID controller can significantly reduce the angular error of the moving platform and provide the stable motion for transferring the divertor.

A Study of the Oxygen Plasma Treatment on the Serviceability of a Wool Fabric

  • Kan, C.W.;Chan, K.;Yuen, C.W.M.
    • Fibers and Polymers
    • /
    • v.5 no.3
    • /
    • pp.213-218
    • /
    • 2004
  • Low temperature plasma (LTP) treatment using oxygen gas was applied to a wool fabric. The LTP treated wool fabric was tested with several methods: ASTM D5035-1995, ASTM D1424-1996, AATCC Test Method 99-2000, AATCC Test Method 61-2001 lA, AATCC Test Method 15-2002 and AATCC Test Method 8-2001 and the results were compared with the industrial requirements (ASTM D3780-02 and ASTM D4155-0l). The results revealed that the LTP treated wool fabric could fulfil the industrial requirements. The results of the investigation were discussed thoroughly in this paper.

Indocyanine green excretion test and changes of plasma enzyme activities in Korean native cattle and dairy cattle (한우 및 유우에서의 indocyanine green 배설시험 및 혈장효소 활성치의 변화)

  • Son, Min-soo;Kim, Cheol-ho;Choi, IL-kwan;Kim, Jin-gu;Hur, Ju-hyeong;Kang, Chung-boo
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.677-681
    • /
    • 1992
  • This experiment was carried out to establish a proper method of indocyanine green(ICG) excrection test for a applicable liver function test in three Korean native cattle average weighing about 450kg and dairy cattle parity of 3~5. The results obtained the half life($T^1/_2$), fractional clearance rate(KICG), retention rate and plasma enzyme activities before or after injection of ICG were as follows. 1. The maximum absorbance of ICG in plasma was at 805nm. 2. Average half life and fractional clearance rate following the injection of ICG 0.25mg/kg body weight were $5.53{\pm}1.27$ minute and $0.131{\pm}0.031$/minute in Korean native cattle, $4.55{\pm}0.68$ minute and $0.156{\pm}0.031$/minute in dairy cattle, respectively. The ICG removal rate was exponentially liner for the first 15 minutes after injection both of Korean native cattle and dairy cattle. 3. Average plasma retention rate when 10, 15, 30 minutes after injection was $35.7{\pm}13.9$, $23.2{\pm}7.1$, $10.8{\pm}3.5%$ in Korean native cattle, $26.8{\pm}3.3$, $14.2{\pm}1.2$, $5.5{\pm}2.2%$ in dairy cattle, respectively. 4. Plasma enzyme activities(AST, ALT, r-GTP) were no variation among the before, during and after injection of ICG. From these results, ICG excretion test to cattle is applicable to evaluation of liver funtion in both clinical and research, and adopted the 15 minutes plasma sample as the sample taken at the ideal time for comparative purposes.

  • PDF

Effect of Plasma Treatment on the Bond Strength of Sn-Pb Eutectic Solder Flip Chip (Sn-Pb 공정솔더 플립칩의 접합강도에 미치는 플라즈마 처리 효과)

  • 홍순민;강춘식;정재필
    • Journal of Welding and Joining
    • /
    • v.20 no.4
    • /
    • pp.498-504
    • /
    • 2002
  • Fluxless flip chip bonding process using plasma treatment instead of flux was investigated. The effect of plasma process parameters on tin-oxide etching characteristics were estimated with Auger depth profile analysis. The die shear test was performed to evaluate the adhesion strength of the flip chip bonded after plasma treatment. The thickness of oxide layer on tin surface was reduced after Ar+H2 plasma treatment. The addition of H2 improved the oxide etching characteristics by plasma. The die shear strength of the plasma-treated Sn-Pb solder flip chip was higher than that of non-treated one but lower than that of fluxed one. The difference of the strength between plasma-treated specimen and non-treated one increased with increase in bonding temperature. The plasma-treated flip chip fractured at solder/TSM interface at low bonding temperature while the fracture occurred at solder/UBM interface at higher bonding temperature.

Establishment of Optimal Conditions for the Hypoosmotic Swelling Test to Evaluate the Integrity of Spermatozoal Plasma Membrane in Dog

  • Jang Hyun-Yong;Jung Yoo-Sung;Kim Jong-Taek;Park Chun-Keun;Cheong Hee-Tae;Kim Choung-Ik;Yang Hoo-Keun
    • Reproductive and Developmental Biology
    • /
    • v.30 no.1
    • /
    • pp.71-74
    • /
    • 2006
  • Hypoosmotic swelling test (HOST) is used for evaluating the plasma membrane function and fertilizing ability in mammal spermatozoa. However, HOS solutions and experimental conditions have not been determined clearly for assessing canine spermatozoa. This study was conducted to examine the HOS solutions and assay conditions, including incubation time (30 to 120 min), storage temperature (4, 17 and $20^{\circ}C$), semen status (fresh and frozen). Maximum spermatozoal plasma membrane swelling was obtained in an 150 mOsm Na-citrate/Fructose solutions with an incubation time for 45 min. The storage temperature and semen status affected the percentage of HOS positive spermatozoa. The HOS test adapted to canine spermatozoa in this study was simple and highly consistent assay with good repeatability. The optimal condition of HOST in canine spermatozoa is an 150 mOsm Na-citrate/Fructose solutions with an incubation time for 45 min regardless of semen storage temperature and semen status.

A case of Diagnosing Paraquat Intoxication on Transferred Patient with Acute Renal Failure (원인 불명의 급성 신부전으로 발현된 급성 파라콰트중독 1례)

  • Gil Hyo Wook;Yang Jong Oh;Lee Eun Young;Hong Sae Yong
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.2 no.1
    • /
    • pp.45-48
    • /
    • 2004
  • Paraquat, a widely used herbicide, is extremely toxic, causing multiple organ failure in human. Many treatment modality has been used, but now paraquat is very fatal drug. Elimination rate of plasma paraquat seems to be a factor for the survival rate. So early diagnosis and early treatment are very important. Plasma paraquat concentration could be measured by radioimmunoassay. But it is impossible that the test was done at Emergency room and the result was checked immediately. There was relation between plasma paraquat concentrations and urine paraquat concentration. Because of its simplicity and low cost, urine paraquat concentration test is complementary to the plasma concentration measurement. If the patient has psychotic problem or unconscious mental state, and is observed unexplained dyspnea and oral ulcer, urine paraquat test is very important to rule out acute paraquat intoxication. We experienced a patient who was presented as unexplained acute renal failure initially and was diagnosed as paraquat intoxication later.

  • PDF