• Title/Summary/Keyword: Plant Water Use Efficiency

Search Result 161, Processing Time 0.024 seconds

Photosynthetic Characteristics of Sedum takevimense on Various Moisture Conditions in a Green Roof System (옥상녹화시스템에서 수분 조건에 따른 섬기린초의 광합성 특성)

  • Li, Hong;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.140-146
    • /
    • 2013
  • This experiment was conducted in order to study the physiological characteristics of Sedum takevimense in different moisture conditions. The photosynthetic rate, water use efficiency and the respiratory rate were determined by using a photable photosynthesis system. According to the results, the best illumination range and moisture range were explicitly selected. The highest photosynthetic rate was at $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and after this value, the trend showed a reduction. When the moisture was 11.31%, the photosynthetic capacity and water use efficiency reached maximum value, but the respiratory rate reached maximum value at 7.91%. According to the measured values, the best illumination range was $600{\sim}1,200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the best moisture range was 7.09~11.31%.

Development of the method for optimal water supply pump operation considering disinfection performance (소독능을 고려한 송수펌프 최적운영기법 개발)

  • Hyung, Jinseok;Kim, Kibum;Seo, Jeewon;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

Prediction of Wave Energy Absorption Efficiency and Wave Loads of a Three-Dimensional Bottom-Mounted OWC Wave Power Device (착저식 OWC 파력발전장치의 파에너지 흡수효율 및 파랑하중 계산)

  • Hong, Do-Chun;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • The wave energy absorption efficiency and the first-order and the time-mean second-order wave loads of a three-dimensional bottom-mounted oscillating water column (OWC) chamber structure are studied. The potential problem is solved by making use of a hybrid Green integral equation associated with the finite-waterdepth free-surface Green function outside a twin chamber and the Rankine Green function inside taking account of the fluctuating air pressure inside the chamber. Numerical results of the primary wave energy converting efficiency and the oscillating and steady wave loads of a three-dimensional bottom-mounted OWC pilot plant have been presented.

Interactions among Carbon Isotope Discrimination, Water Use Efficiency and Nitrogen Nutrition in Wheat and Barley (밀과 보리에 있어서 탄소동위원소차별, 수분이용효율, 질소영양간의 상호작용)

  • Young Kil, Kang;Richard A., Richards;Anthony G., Condon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.3
    • /
    • pp.318-331
    • /
    • 1996
  • Large and small seeds (44 and 22 mg per caryopsis) of a spring wheat (cv. Kulin) and a spring barley (cv. Skiff) were sown at two nitrogen rates (equivalent to 10 and 32 g m$^{-2}$ ) in well-watered pots under outdoor conditions to determine the effects of seed size and nitrogen (N) nutrition on water use efficiency (WUE) and carbon isotope discrimination ($\Delta$) and to evaluate interaction among $\Delta$, WUE and N nutrition in wheat and barley. Barley produced, on average, 105% more biomass (root+shoot dry weight) than wheat at stem elongation because of early vigor. By anthesis this difference had disappeared as wheat had 16% more biomass than barley which headed 3 days earlier. Compared to plants grown from small seed, plants grown from large seed had much greater biomass in wheat than in barley at stem elongation and anthesis. Higher N nutrition increased average biomass of wheat and barley by 40 and 31%, respectively, at anthesis. Barley had 35 and 20% greater WUE (biomass gained/transpiration) than wheat at stem elongation and anthesis, respectively, and 2.0 to 3.6% lower $\Delta$ in aboveground shoots depending on growth stages and plant parts than wheat which had a greater stomatal conductance than barley. Seed size had a variable effect on WUE and did not affected $\Delta$ values. Water use efficiency was not affected by N rate at stem elongation in wheat and barley whereas WUE was increased 2 and 7%, respectively, in wheat and barley at anthesis with increasing N from 10 to 32 g m$^{-2}$ . High N plants had about 2.5% lower $\Delta$ values regardless of growth stages than low N plants across species and seed sizes. Carbon isotope discrimination was negatively correlated with WUE at anthesis but not at stem elongation.

  • PDF

Reduction of the Reheater Spray for Coal Fired Thermal Power Plant (석탄화력발전소의 재열저감수 저감방안)

  • Kim, Hyung-Deok;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.46-50
    • /
    • 2013
  • When four operation parameters are adjusted, the temperature of reheater steam is around the designed operator temperature and the decrease of reheater spray flow rate is achieved. As a result, the decrease of thermal efficiency also can be prevented. To keep the reheater exit temperature on the designed value and decrease the use of reheater spray flow rate, the control of four operation parameters is considered and applied in the operation of a thermal power plant.

  • PDF

CFD ANALYSIS ON THE CHARACTERISTICS FOR FLOCCULATORS OF VERTICAL PADDLE AND HYDRO-FOIL TYPE (수직 패들형 및 하이드로 포일형 응집기 특성의 전산유체역학 해석)

  • Shin, J.H.;Chang, S.M.;Cho, Y.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.24-30
    • /
    • 2016
  • In the water purification plant, the mixture of water and chemical from the mixing basin enters the flocculation basin. The rotating flocculators are generally used for the efficient flocculation of dregs. In this paper, the performance of flocculators of a vertical paddle type, widely used in the typical flocculation basins, and a hydro-foil type, recently disseminated in the field, are compared with each other by use of the numerical method. Also the characteristics and the efficiency are analyzed with CFD techniques. The strain rate and the eddy viscosity are compared for two types to predict the mixing efficiency, and the maximum speed and its location are pursued from the computed data. The hydrofoil type shows that the eddy viscosity is enhanced 1.66 to 3.03 times larger than that of vertical paddle type, and also produced 1.87 to 1.95 times larger flocs for each stage. However, the rapid rotation of hydrofoil may chop the floc to small size due to the higher turbulence intensity. From the result of computation, the strong and weak points of each type have been analyzed for the decision making.

Comparison in Water Consumption, Plant and Fruit Growth of Different Europe Eggplant Cultivars in Coir Substrate Hydroponics under High Temperature Conditions (고온조건하에서 코이어 배지에서 유럽형 가지 품종별 수분소비량, 식물체 생육 및 과실 특성 비교)

  • Seoa Yoon;Jeongman Kim;Eunyoung Choi;Kiyoung Choi;Kyunglee Choi;Kijeong Nam;Seokkwi Oh;Jonghyang Bae;Yongbeom Lee
    • Journal of Bio-Environment Control
    • /
    • v.32 no.2
    • /
    • pp.139-147
    • /
    • 2023
  • This study aims to select eggplant cultivars adaptive to the hot temperature period greenhouse climate by water consumption, and growth performance of plants and fruits of different European eggplant cultivars, including 'Bartok (BA)', 'Bowie (BO)', 'Black Pearl (BP)', 'Ishbilia (I)', 'Mabel (M)', 'Vestale (VE)' and 'Velia (VL)', in substrate hydroponic cultivation under hot and humid greenhouse conditions. On the 118 DAT, the leaf number and stem dry weight were highest in 'VL', followed by 'M', and there was no significant difference in leaf dry weight among cultivars. The marketable fruit number per plant was 16.4 for 'M', which was higher than other cultivars, and 'VE' and 'VL' were 8.5 and 8.8, respectively. The weight per fruit was low for 'M' at 136 g, and the highest in 'VE' and 'VL' at 332 and 281 g, respectively. There was no significant difference in fruit production per plant. In this study, 'M', which has high water use efficiency and a large number of fruits, and 'VL', which required less quantity to water consumption for producing 200 g of fruit and had a high product weight, will have excellent adaptability in the UAE greenhouse condition.

Characteristics of Coagulation Treatment for Wood Tar Waste Water in a Biomass Gasification Plant (바이오매스 가스화 발전설비의 목질계 타르폐수 응집 처리 특성)

  • Kim, I tae;Ahn, Kwangho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.573-577
    • /
    • 2015
  • There are difficulties in removing wood tar wastewater coming from the power plants that use wood-based fuels due to its intermittent occurrences and severe changes in the amount and concentration. This study investigated the treatment characteristics through physicochemical treatment, an improved method from the existing ones using bag filters and activated carbons to treat wood tar wastewater. In the case of chemical properties of wood tar wastewater, the content of phenols was found to be more than two times higher than that of guaiacols and carbohydrates. Installation is done to ensure that NaOH and PAC are injected automatically according to the change of pH, and then pH, turbidity and SS of the final treated water were examined. The results were 5.9, 12.6 NTU and 15.1 mg/L respectively, which confirmed the possibility of the treated water as circulation water of power plants. In the physical treatment process using a conventional bag filter, removal efficiency of chemicals was about 20%, but the treatment efficiency was improved to show chemical removal efficiency of about 80% through flocculation and sedimentation.

Performance Evaluation and Economic Analysis on the Integrated Small Hydro Power Generation Device Using a Discharged Water of Sewage Treatment Plant (하수처리장의 방류수를 이용한 일체형 발전장치의 성능평가 및 경제성 분석)

  • Park, Yoo-Sin;Kim, Ki-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.486-491
    • /
    • 2017
  • The water discharged from sewage treatment plants has been considered to be useless, due to itslack of economic utility for small hydro power generation. Considering that most sewage treatment facilities have a water head of less than 2 meters and their flow rate is constant, it is necessary to develop a small hydro power generation device capable of maintaining stable power generation and efficiency. This paper presents the development of anintegrated small hydro power generation system and presents its performance evaluation and results. Then, the economics and use of the system for practical applications are suggested. As a result, it is foundthat the generator efficiency is 92%, the electric energy produced is 10kWh and the economic efficiency, as described by the B/C ratio,is 1.0 or more. Particularly, if the operating level of the generation device is maintained at 80% or more of the rated power, it is possible to secure its economic efficiency and, after 23 years, the investment cost will bereturned. The integrated hydro power generation device is expected to have a positive effect not only in terms of the water discharged from the sewage treatment plant, but also in terms of facilities capable of securing similar flow characteristics.

Effect of Shading Treatments on Photosynthetic Activity of Adenophora triphylla var. japonicum (차광처리가 잔대의 광합성 활성에 미치는 영향)

  • Kim, Jeong-Woon;Yoon, Jun-Hyuck;Jeon, Kwon-Seok;Chung, Jae-Min;Jung, Hye-Ran;Cho, Min-Gi;Moon, Hyun-Shik
    • Journal of agriculture & life science
    • /
    • v.46 no.4
    • /
    • pp.93-99
    • /
    • 2012
  • This study was conducted to investigate photosynthetic characteristics of two-year-old of Adenophora triphylla var. japonicum grown under control (full sunlight) and three different shading treatment (25, 50, and 75% shading treatment). Total chlorophyll contents like chlorophyll a and b content had not significant difference among treatments. Net photosynthetic rate of control and 25% treatment were higher than 50% and 75% treatment. Seedlings grown under full sunlight showed the highest photosynthetic activity such as photosynthetic rate, stomatal conductance and intercellular $CO_2$ concentration except for water use efficiency which was relative higher under 50% and 75% treatment.